Cervical spine imaging using standard C-arm fluoroscopy

被引:65
|
作者
Giordano, Brian D. [1 ]
Baumhauer, Judith F. [1 ]
Morgan, Thomas L. [2 ]
Rechtine, Glenn R. [1 ]
机构
[1] Univ Rochester, Med Ctr, Dept Orthoped & Rehabil, Rochester, NY 14642 USA
[2] Univ Rochester, Med Ctr, Radiat Safety Unit, Rochester, NY 14642 USA
关键词
cervical spine imaging; C-arm fluoroscope; practitioner radiation exposure; patient radiation exposure; minimal access techniques;
D O I
10.1097/BRS.0b013e31817e69b7
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. A cadaveric cervical spine specimen is imaged with a standard C-arm fluoroscope during a simulated procedure. Patient and surgeon exposure to radiation is estimated by placing dosimeters at various locations in 3-dimensional space. Objective. The purpose of this study was to evaluate radiation exposure to patient and surgeon when using C-arm fluoroscopy during a simulated cadaveric surgical procedure involving the cervical spine. Summary of the Background Data. The use of mobile fluoroscopy has become commonplace in orthopaedics. With the current trend towards minimal access techniques, fluoroscopy has become requisite to achieving satisfactory outcomes. Studies have shown that spine surgeons may be at elevated risk for radiation exposure compared to other orthopaedists. Exposure while using C-arm fluoroscopy for procedures involving the pelvis, as well as thoracic and lumbar spine has been documented. However, there are no equivalent studies that evaluate exposure during cervical spine imaging. Methods. A standard OEC 9800 C-arm was used to image a prepared cadaveric cervical spine specimen, which was suspended on an adjustable platform. Film badge dosimeters were mounted at various positions and angles to detect direct and scatter radiation. Testing was conducted in various radiation dose mapping "scenarios." The configurations tested altered the proximity of the specimen and jig relative to the radiation source. We attempted to capture radiation exposure in various locations, from a best-case to a worst-case scenario, as may be realistically encountered in a procedural setting. Results. Potential exposure to the patient and surgeon were consistently measurable, and of concern. As the imaged specimen was positioned closer to the radiation source, exposure to the patient was markedly amplified. Exposure to the surgeon did not increase as dramatically. There was a great degree of variability in the exposure doses recorded by the peripheral dosimeters. Even dosimeters that were placed in the same plane diverged widely in their measured exposure. This highlights the influence of the shape of the imaged specimen on reflected scatter. Scatter radiation doses on both sides of the specimen were similar. Conclusion. Care should be taken when working on both sides of the imaged subject. Considerable radiation exposure can be encountered when working with a C-arm fluoroscope if appropriate precautions are not observed. All appropriate radiation dose-reducing measures should be strictly enforced by the supervising physician to minimize risk to the patient and the medical team.
引用
收藏
页码:1970 / 1976
页数:7
相关论文
共 50 条
  • [21] Utility of Intraoperative C-Arm Fluoroscopy for Frontal Sinusotomy
    Lee, Seung-Sin
    [J]. EWHA MEDICAL JOURNAL, 2009, 32 (02): : 61 - 64
  • [22] C-arm Positioning Using Virtual Fluoroscopy for Image-Guided Surgery
    De Silva, T.
    Punnoose, J.
    Uneri, A.
    Goerres, J.
    Jacobson, M.
    Ketcha, M. D.
    Manbachi, A.
    Vogt, S.
    Kleinszig, G.
    Khanna, A. J.
    Wolinksy, J. -P.
    Osgood, G.
    Siewerdsen, J. H.
    [J]. MEDICAL IMAGING 2017: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2017, 10135
  • [23] Seed segmentation in C-arm fluoroscopy for brachytherapy implant reconstruction
    Vikal, S.
    Jain, A.
    Deguet, A.
    Song, D.
    Fichtinger, G.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 2229 - 2229
  • [24] Radiation exposure to the hands from mini C-arm fluoroscopy
    Singer, G
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2005, 30A (04): : 795 - 797
  • [25] Survey of terminology used for the intraoperative direction of C-arm fluoroscopy
    Pally, Elliott
    Kreder, Hans J.
    [J]. CANADIAN JOURNAL OF SURGERY, 2013, 56 (02) : 109 - 112
  • [26] Hardware accelerated C-arm CT and fluoroscopy: A pilot study
    Riabkov, Dmitri
    Brown, Todd
    Cheryauka, Arvi
    Tokhtuev, Alexander
    [J]. MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2008, 6913
  • [27] C-arm fluoroscopy for the removal of an intraorbital foreign body in a cat
    Kim, Se Eun
    Park, Young Woo
    Ahn, Jae Sang
    Son, Won Gyun
    Jeong, Manbok
    Yoon, Junghee
    Seo, Kangmoon
    [J]. JOURNAL OF FELINE MEDICINE AND SURGERY, 2011, 13 (02) : 112 - 115
  • [28] The Preventative Knowledge and Experience of Anesthesiology Students with C-arm Fluoroscopy
    Kaplan, Betul
    Avci, Sezer
    [J]. EUROPEAN JOURNAL OF THERAPEUTICS, 2023, 29 (02): : 201 - 207
  • [29] Odontoid screw placement using isocentric 3-dimensional C-arm fluoroscopy
    Summers, Lori E.
    Kouri, Joshua G.
    Yang, Mu
    Jacob, R. Patrick
    [J]. JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2008, 21 (01): : 45 - 48
  • [30] Multi-angle laser device improves novice learning of C-arm fluoroscopy for lumbar spine surgery
    Zhuang, Yuan-Dong
    Li, Rui-Jin
    Wu, Jia-Jun
    He, Xue-Wei
    Zou, Wen-Bin
    Xu, Xu-Chu
    Lu, Si-Qi
    Chen, Chun-Mei
    [J]. PLOS ONE, 2024, 19 (03):