Reproducibility evaluation of 99mTc-mebrofenin hepatobiliary scintigraphy using SPECT for future remnant liver functional assessment before major hepatectomy

被引:1
|
作者
Nivaggioni, G. [1 ]
Baillet, C. [1 ]
Beron, A. [1 ]
Truant, S. [2 ]
Duhamel, A. [3 ,4 ]
Pruvot, F. R. [2 ,4 ]
Huglo, D. [1 ,4 ]
机构
[1] CHRU Lille, Hop Huriez, Nucl Med Serv, F-59037 Lille, France
[2] CHRU Lille, Hop Huriez, Serv Chirurg Digest & Transplantat, F-59037 Lille, France
[3] CHRU Lille, Plateforme Aide Methodol, F-59037 Lille, France
[4] Univ Lille, Fac Med, F-59000 Lille, France
关键词
Hepatobiliary scintigraphy; Tc-99m-mebrofenin; Reproducibility; Hepatectomy; Quantification; IODIDA CLEARANCE RATE; HEPATOCELLULAR-CARCINOMA; PREOPERATIVE ASSESSMENT; HEPATIC-FUNCTION; RESECTION; RISK; FAILURE; MODEL;
D O I
10.1016/j.mednuc.2015.01.005
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
Purpose. - Performances of Tc-99m-mebrofenin hepatobiliary scintigraphy (BIBS) are currently evaluated before major hepatic resection for early detection of liver failure in high risk patients. Published studies included small numbers of patients with planar scintigraphy, and more recently SPECT data. Our aim was to evaluate intra- and interobserver reproducibility of HBS in planar and SPECT modalities for functional assessment of the future remnant liver (FRL) before major hepatic resection. We also evaluated the impact of potential variability factors such as biliary excretion and isocontour threshold choice. Methods. - All the scans were processed twice by three observers. Two regions of interest were drawn around total liver (TL) and FRL, on the planar dataset and with a threshold based algorithm on SPECT after registration with contrast-enhanced CT. Intra- and interobserver reproducibility of the FRL/TL ratio were calculated. When biliary excretion was already visible on SPECT acquisition, it was corrected and the ratio compared before and after correction. The results were also compared between different thresholds of the maximum liver value (-4%, -2%, +2%, +4% of the optimal threshold chosen by the observer). Results. - Thirty patients were included. The intraobserver reproducibility was good (R-2 = 0.847, 0.830 and 0.966) when calculated on planar modality and better with SPECT (R-2 = 0.957, 0.962 and 0.984). There was no significant difference after biliary excretion correction (P = 0.29, P = 0.99 and P = 0.61 for the three observers). The threshold modification caused significant but minor differences (1% on average) for the evaluated thresholds. Conclusions. - The FRL functional evaluation with FIBS including a SPECT acquisition provides a reproducible assessment, hardly affected by potential variability factors, allowing its use in multicentric studies. (C) 2015 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:182 / 191
页数:10
相关论文
共 50 条
  • [11] Optimized separation of left and right liver lobe in dynamic 99mTc-mebrofenin hepatobiliary scintigraphy using a hybrid SPECT-CT scanner
    Geisel, Dominik
    Luedemann, Lutz
    Gebauer, Bernhard
    Froeling, Vera
    Prasad, Vikas
    Heimann, Uwe
    Stockmann, Martin
    Malinowski, Maciej
    Hamm, Bernd
    Brenner, Winfried
    Denecke, Timm
    ANNALS OF NUCLEAR MEDICINE, 2014, 28 (09) : 897 - 902
  • [12] Optimized separation of left and right liver lobe in dynamic 99mTc-mebrofenin hepatobiliary scintigraphy using a hybrid SPECT-CT scanner
    Dominik Geisel
    Lutz Lüdemann
    Bernhard Gebauer
    Vera Fröling
    Vikas Prasad
    Uwe Heimann
    Martin Stockmann
    Maciej Malinowski
    Bernd Hamm
    Winfried Brenner
    Timm Denecke
    Annals of Nuclear Medicine, 2014, 28 : 897 - 902
  • [13] 99mTc-mebrofenin hepatobiliary scintigraphy and volume metrics before liver preparation: correlations and discrepancies in non-cirrhotic patients
    Guiu, Boris
    Deshayes, Emmanuel
    Panaro, Fabrizio
    Sanglier, Florian
    Cusumano, Caterina
    Herrerro, Astrid
    Sgarbura, Olivia
    Molinari, Nicolas
    Quenet, Francois
    Cassinotto, Christophe
    ANNALS OF TRANSLATIONAL MEDICINE, 2021, 9 (09)
  • [14] HEPATOBILIARY SCINTIGRAPHY IN THE ASSESSMENT OF FUNCTIONAL FUTURE REMNANT LIVER PRIOR TO PARTIAL HEPATECTOMY
    Tavare, N.
    INTERNAL MEDICINE JOURNAL, 2012, 42 : 2 - 2
  • [15] The utility of 99mTc-mebrofenin hepatobiliary scintigraphy with SPECT/CT for selective internal radiation therapy in hepatocellular carcinoma
    Labeur, Tim A.
    Cieslak, Kasia P.
    Van Gulik, Thomas M.
    Takkenberg, R. Bart
    van der Velden, Sandra
    Lam, Marnix G. E. H.
    Klumpen, Heinz-Josef
    Bennink, Roel J.
    van Delden, Otto M.
    NUCLEAR MEDICINE COMMUNICATIONS, 2020, 41 (08) : 740 - 749
  • [16] Future remnant liver function estimated by combining liver volumetry on magnetic resonance imaging with total liver function on 99mTc-mebrofenin hepatobiliary scintigraphy: can this tool predict post-hepatectomy liver failure?
    Chapelle, Thiery
    De Beeck, Bart Op
    Huyghe, Ivan
    Francque, Sven
    Driessen, Ann
    Roeyen, Geert
    Ysebaert, Dirk
    De Greef, Kathleen
    HPB, 2016, 18 (06) : 494 - 503
  • [17] Evaluating the effects of radiation dose to normal liver parenchyma following radioembolisation using 99mTc-mebrofenin hepatobiliary scintigraphy
    Willowson, Kathy
    Schembri, Geoff
    Wannheden, Carl
    Bailey, Dale
    JOURNAL OF NUCLEAR MEDICINE, 2018, 59
  • [18] The role of 99mTc-Mebrofenin SPECT/CT in preoperative determination of liver functional volume
    Bakos, A.
    Pavics, L.
    Sipka, G.
    Farkas, I.
    Miko, Z.
    Czekus, T.
    Nagy, S.
    Nemet, R.
    Urban, S.
    Libor, L.
    Geczi, T.
    Hohn, J.
    Besenyi, Z.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2022, 49 (SUPPL 1) : S472 - S473
  • [19] Determination of the segmental hepatic clearance rate of 99mTc-mebrofenin and its application in the functional assessment of future liver remnant after liver resection
    Una-Gorospe, J. A.
    REVISTA ESPANOLA DE MEDICINA NUCLEAR E IMAGEN MOLECULAR, 2021, 40 (06): : 385 - 396
  • [20] Joint EANM/SNMMI/IHPBA procedure guideline for [99mTc]Tc-mebrofenin hepatobiliary scintigraphy SPECT/CT in the quantitative assessment of the future liver remnant function
    Arntz, Pieter J. W.
    Deroose, Christophe M.
    Marcus, Charles
    Sturesson, Christian
    Panaro, Fabrizio
    Erdmann, Joris
    Manevska, Nevena
    Moadel, Renee
    de Geus-Oei, Lioe-Fee
    Bennink, Roel J.
    HPB, 2023, 25 (10) : 1131 - 1144