Measurement of anastomosis geometry in lower extremity bypass grafts with 3-D ultrasound imaging

被引:6
|
作者
Leotta, DF [1 ]
Primozich, JF [1 ]
Lowe, CM [1 ]
Karr, LN [1 ]
Bergelin, RO [1 ]
Beach, KW [1 ]
Zierler, RE [1 ]
机构
[1] Univ Washington, Dept Surg, Seattle, WA 98195 USA
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 2005年 / 31卷 / 10期
关键词
3-D; ultrasound; bypass graft; anastomosis; power Doppler; vascular imaging;
D O I
10.1016/j.ultrasmedbio.2005.06.012
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The attachment sites of lower extremity bypass grafts are known to exhibit a wide range of geometries. Factors that determine the geometry of a given anastomosis include graft material, graft site, native vessel size, graft size and individual patient anatomy. Therefore, it is difficult to specify a standard anastomosis geometry before surgery and difficult to predict the effect of the geometry on long-term graft patency. We have used 3-D ultrasound imaging to study 46 proximal anastomoses of lower limb bypass grafts. We have developed methods to characterize the 3-D geometry of the anastomosis in terms of component sizes and angles. These detailed geometric measurements describe a range of anastomosis geometries and establish standardized parameters across cases that can be used to relate anastomosis geometry to outcome.
引用
收藏
页码:1305 / 1315
页数:11
相关论文
共 50 条
  • [1] Revision of failing lower extremity bypass grafts
    Dougherty, MJ
    Calligaro, KD
    DeLaurentis, DA
    AMERICAN JOURNAL OF SURGERY, 1998, 176 (02): : 126 - 130
  • [2] CT Angiography of Lower Extremity Vascular Bypass Grafts
    Toomay, Seth M.
    Dolmatch, Bart L.
    TECHNIQUES IN VASCULAR AND INTERVENTIONAL RADIOLOGY, 2006, 9 (04) : 172 - 179
  • [3] 3-D vascular ultrasound imaging
    Fenster, A
    Lee, D
    Downey, D
    WHERE INSTRUMENTATION IS GOING - CONFERENCE PROCEEDINGS, VOLS 1 AND 2, 1998, : 559 - 561
  • [4] 3-D ultrasound imaging: A review
    Fenster, A
    Downey, DB
    IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 1996, 15 (06): : 41 - 51
  • [5] Balloon angioplasty for revision of failing lower extremity bypass grafts
    Ali, Haitham
    Elbadawy, Ahmed
    Saleh, Mahmoud
    Hasaballah, Ayman
    JOURNAL OF VASCULAR SURGERY, 2015, 62 (01) : 93 - 100
  • [6] Automatic 3-D Imaging and Measurement of Human Spines With a Robotic Ultrasound System
    Yang, Cui
    Jiang, Mingyao
    Chen, Mianjie
    Fu, Maoqing
    Li, Jianyi
    Huang, Qinghua
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70
  • [7] MAGNETIC RESONANCE IMAGING AND FREEHAND 3-D ULTRASOUND PROVIDE SIMILAR ESTIMATES OF FREE ACHILLES TENDON SHAPE AND 3-D GEOMETRY
    Devaprakash, Daniel
    Lloyd, David G.
    Barrett, Rod S.
    Obst, Steven J.
    Kennedy, Ben
    Adams, Kahlee L.
    Hunter, Adam
    Vlahovich, Nicole
    Pease, David L.
    Pizzolato, Claudio
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2019, 45 (11): : 2898 - 2905
  • [8] 3-D Ultrasound Imaging Of Lung Lesions
    Warren, W.
    Parrish, S. C.
    Browning, R.
    Malafronte, P.
    Nations, J.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2016, 193
  • [9] Advances in 3-D vascular ultrasound imaging
    Fenster, Aaron
    American Society of Mechanical Engineers, Bioengineering Division (Publication) BED, 1999, 43 : 83 - 84
  • [10] Coronary bypass grafts: Assessment of critical 3-D anatomic features
    Carroll, JD
    Chen, SYJ
    Groves, BM
    Schaefer, C
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (02) : 139A - 139A