Automatic 3-D Imaging and Measurement of Human Spines With a Robotic Ultrasound System

被引:39
|
作者
Yang, Cui [1 ]
Jiang, Mingyao [1 ]
Chen, Mianjie [1 ]
Fu, Maoqing [2 ]
Li, Jianyi [3 ,4 ]
Huang, Qinghua [5 ]
机构
[1] South China Univ Technol, Sch Elect & Informat Engn, Guangzhou 510640, Peoples R China
[2] Southern Med Univ, Affiliated Hosp 7, Dept Spine Surg, Foshan 528244, Peoples R China
[3] Southern Med Univ, Sch Basic Med Sci, Dept Anat, Guangdong Prov Key Lab Med Biomech, Guangzhou 510515, Peoples R China
[4] Southern Med Univ, Affiliated Hosp 7, Foshan 528244, Peoples R China
[5] Northwestern Polytech Univ, Sch Artificial Intelligence Opt & Elect iOPEN, Xian 710072, Peoples R China
基金
中国国家自然科学基金;
关键词
3-D ultrasound imaging and measurement; automatic recognition and scanning; deep learning; RGB-depth (RGB-D) feature fusion; spine; REGISTRATION; CALIBRATION; TRACKING;
D O I
10.1109/TIM.2021.3085110
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Comparing with X-ray, ultrasound imaging has the advantages of no radiation and easy operation, etc., which is expected to be an effective alternative in clinical assessment for the human spine. At present, freehand scanning is mainly used in ultrasound imaging field, and recently robot-assisted scanning has emerged as a promising way to gradually reduce human intervention. However, the automatic recognition and scanning, as well as the control strategy of robots that guarantee the tight coupling between a probe and human skin, are still challenges. Moreover, the current measurement method of the spine is usually conducted based on plain radiographs, which lacks spatial structure information of spine. In this article, a new radiation-free robotic ultrasound system for 3-D imaging and a measurement method of the spine based on 3-D imaging are presented. A fully convolutional network (FCN) named fuse-Unet based on RGB and depth images captured by an RGB-depth (RGB-D) sensor Kinect, is proposed to realize the automatic recognition of human spine area and scanning path pre-planning. Then a six-degree-of-freedom robotic arm plays the role of a doctor to complete the automatic scanning along the pre-planning path, during which a normal-vector-based method and two force sensors are used to ensure that the probe well fits the spine area. Finally, 3-D ultrasound reconstruction and visualization of the spine are realized, based on which cobb angles are calculated for assessing the morphological structure of the spine. Phantom and in vivo experiments are conducted for evaluating the performance of the proposed system. Experimental results validate the practicability and accuracy of the system, indicating its potential for clinical application.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] An Automatic 3-D Ultrasound and Photoacoustic Combined Imaging System for Human Inflammatory Arthritis
    Peng, Xiaorui
    Dentinger, Aaron
    Kewalramani, Shivangi
    Xu, Zhanpeng
    Gray, Steven
    Ghose, Soumya
    Tan, Yew Teck
    Yang, Zhaoyuan
    Jo, Janggun
    Chamberland, David
    Xu, Guan
    Abdulaziz, Nada
    Gandikota, Girish
    Mills, David
    Wang, Xueding
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2023, 70 (12) : 1691 - 1702
  • [2] 3-D line-scan imaging system for robotic measurement
    Petty, RS
    Godber, SX
    Evans, JPO
    Robinson, M
    THREE-DIMENSIONAL AND UNCONVENTIONAL IMAGING FOR INDUSTRIAL INSPECTION AND METROLOGY, 1996, 2599 : 129 - 140
  • [3] Automatic Diagnosis of Carotid Atherosclerosis Using a Portable Freehand 3-D Ultrasound Imaging System
    Li, Jiawen
    Huang, Yunqian
    Song, Sheng
    Chen, Hongbo
    Shi, Junni
    Xu, Duo
    Zhang, Haibin
    Chen, Man
    Zheng, Rui
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2024, 71 (02) : 266 - 279
  • [4] Semi-automatic Measurement of Scoliotic Angle Using a Freehand 3-D Ultrasound System Scolioscan
    Zhou, Guang-Quan
    Jiang, Wei-Wei
    Lai, Ka-Lee
    Lam, Tsz-Ping
    Cheng, Jack Chun-Yiu
    Zheng, Yong-Ping
    XIV MEDITERRANEAN CONFERENCE ON MEDICAL AND BIOLOGICAL ENGINEERING AND COMPUTING 2016, 2016, 57 : 341 - 346
  • [5] Development of Automatic Assessment Framework for Spine Deformity Using Freehand 3-D Ultrasound Imaging System
    Chen, Hongbo
    Qian, Liyue
    Gao, Yuchong
    Zhao, Jianhao
    Tang, Yiwen
    Li, Jiawen
    Le, Lawrence H.
    Lou, Edmond
    Zheng, Rui
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2024, 71 (03) : 408 - 422
  • [6] CLINICAL EVALUATION OF A 3-D AUTOMATIC ANNOTATION METHOD FOR BREAST ULTRASOUND IMAGING
    Jiang, Wei-Wei
    Li, Cheng
    Li, An-Hua
    Zheng, Yong-Ping
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2016, 42 (04): : 870 - 881
  • [7] 3-D vascular ultrasound imaging
    Fenster, A
    Lee, D
    Downey, D
    WHERE INSTRUMENTATION IS GOING - CONFERENCE PROCEEDINGS, VOLS 1 AND 2, 1998, : 559 - 561
  • [8] 3-D ultrasound imaging: A review
    Fenster, A
    Downey, DB
    IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 1996, 15 (06): : 41 - 51
  • [9] Automatic registration of 3-D ultrasound images
    Department of Engineering, University of Cambridge, Cambridge, United Kingdom
    不详
    Ultrasound Med. Biol., 6 (841-854):
  • [10] Automatic registration of 3-D ultrasound images
    Rohling, RN
    Gee, AH
    Berman, L
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1998, 24 (06): : 841 - 854