Automatic 3-D Imaging and Measurement of Human Spines With a Robotic Ultrasound System

被引:39
|
作者
Yang, Cui [1 ]
Jiang, Mingyao [1 ]
Chen, Mianjie [1 ]
Fu, Maoqing [2 ]
Li, Jianyi [3 ,4 ]
Huang, Qinghua [5 ]
机构
[1] South China Univ Technol, Sch Elect & Informat Engn, Guangzhou 510640, Peoples R China
[2] Southern Med Univ, Affiliated Hosp 7, Dept Spine Surg, Foshan 528244, Peoples R China
[3] Southern Med Univ, Sch Basic Med Sci, Dept Anat, Guangdong Prov Key Lab Med Biomech, Guangzhou 510515, Peoples R China
[4] Southern Med Univ, Affiliated Hosp 7, Foshan 528244, Peoples R China
[5] Northwestern Polytech Univ, Sch Artificial Intelligence Opt & Elect iOPEN, Xian 710072, Peoples R China
基金
中国国家自然科学基金;
关键词
3-D ultrasound imaging and measurement; automatic recognition and scanning; deep learning; RGB-depth (RGB-D) feature fusion; spine; REGISTRATION; CALIBRATION; TRACKING;
D O I
10.1109/TIM.2021.3085110
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Comparing with X-ray, ultrasound imaging has the advantages of no radiation and easy operation, etc., which is expected to be an effective alternative in clinical assessment for the human spine. At present, freehand scanning is mainly used in ultrasound imaging field, and recently robot-assisted scanning has emerged as a promising way to gradually reduce human intervention. However, the automatic recognition and scanning, as well as the control strategy of robots that guarantee the tight coupling between a probe and human skin, are still challenges. Moreover, the current measurement method of the spine is usually conducted based on plain radiographs, which lacks spatial structure information of spine. In this article, a new radiation-free robotic ultrasound system for 3-D imaging and a measurement method of the spine based on 3-D imaging are presented. A fully convolutional network (FCN) named fuse-Unet based on RGB and depth images captured by an RGB-depth (RGB-D) sensor Kinect, is proposed to realize the automatic recognition of human spine area and scanning path pre-planning. Then a six-degree-of-freedom robotic arm plays the role of a doctor to complete the automatic scanning along the pre-planning path, during which a normal-vector-based method and two force sensors are used to ensure that the probe well fits the spine area. Finally, 3-D ultrasound reconstruction and visualization of the spine are realized, based on which cobb angles are calculated for assessing the morphological structure of the spine. Phantom and in vivo experiments are conducted for evaluating the performance of the proposed system. Experimental results validate the practicability and accuracy of the system, indicating its potential for clinical application.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] 3-D Follicle Extraction and Volume Estimation for Mobile Reproduction Ultrasound Imaging System
    Liu, Jun
    Guan, Bo
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2018, 8 (04) : 746 - 754
  • [42] Automatic calibration of a robotized 3D ultrasound imaging system by visual servoing
    Krupa, Alexandre
    2006 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA), VOLS 1-10, 2006, : 4136 - 4141
  • [43] Automatic 3-D Measurement Method for Nonuniform Moving Objects
    Duan, Minghui
    Jin, Yi
    Chen, Huaian
    Zheng, Jinjin
    Zhu, Changan
    Chen, Enhong
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70
  • [44] A preliminary evaluation work on a 3-D ultrasound imaging system for 2-D array transducer
    Zhong, Xiaoli
    Li, Xu
    Yang, Jiali
    Li, Chunyu
    Song, Junjie
    Ding, Mingyue
    Ming Yuchi
    MEDICAL IMAGING 2016: ULTRASONIC IMAGING AND TOMOGRAPHY, 2016, 9790
  • [45] 3-D ultrasound
    Staedter, T
    TECHNOLOGY REVIEW, 2003, 106 (06): : 73 - 73
  • [46] Validation of 3D reconstructions of a mimicked femoral artery with an ultrasound imaging robotic system
    Janvier, Marie-Ange
    Soulez, Gilles
    Allard, Louise
    Cloutier, Guy
    MEDICAL PHYSICS, 2010, 37 (07) : 3868 - 3879
  • [47] ABDOMINAL AORTIC ANEURYSM IMAGING WITH 3-D ULTRASOUND: 3-D-BASED MAXIMUM DIAMETER MEASUREMENT AND VOLUME QUANTIFICATION
    Long, A.
    Rouet, L.
    Debreuve, A.
    Ardon, R.
    Barbe, C.
    Becquemin, J. P.
    Allaire, E.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2013, 39 (08): : 1325 - 1336
  • [48] 3-D measurement system for use in microelectronics
    Lee, Mikyoung
    Pecht, Michael
    Tyson, John
    Schmidt, Timothy
    Advanced Packaging, 2003, 12 (11): : 33 - 34
  • [49] Reliability and validity of splenic volume measurement by 3-D ultrasound
    Hidaka, Hisashi
    Nakazawa, Takahide
    Wang, Guoqin
    Kokubu, Shigehiro
    Minamino, Tsutomu
    Takada, Juichi
    Tanaka, Yoshiaki
    Okuwaki, Yusuke
    Watanabe, Masaaki
    Shibuya, Akitaka
    Koizumi, Wasaburo
    HEPATOLOGY RESEARCH, 2010, 40 (10) : 979 - 988
  • [50] 3-D surface reconstruction in automatic recognition system
    Matveev, IA
    Murynin, AB
    23RD INTERNATIONAL CONGRESS ON HIGH-SPEED PHOTOGRAPHY AND PHOTONICS, PT 1, 1999, 3516 : 417 - 425