Comparison of implant cost and surgical time in arthroscopic transosseous and transosseous equivalent rotator cuff repair

被引:21
|
作者
Black, Eric M. [1 ]
Austin, Luke S. [2 ]
Narzikul, Alexa [2 ]
Seidl, Adam J. [2 ]
Martens, Kelly [3 ]
Lazarus, Mark D. [2 ]
机构
[1] Summit Med Grp, Dept Orthopaed Surg, Berkeley Hts, NJ USA
[2] Thomas Jefferson Univ Hosp, Dept Orthopaed Surg, Rothman Inst, Philadelphia, PA 19107 USA
[3] Midatlantic Permanente Med Grp, Dept Orthopaed Surg, Largo, MD USA
关键词
Arthroscopic transosseous; rotator cuff; cost; operative time; value; transosseous equivalent; DOUBLE-ROW FIXATION; SINGLE-ROW; TEAR COMPLETION; OUTCOMES; METAANALYSIS; STRENGTH;
D O I
10.1016/j.jse.2016.01.003
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: We investigated the cost savings associated with arthroscopic transosseous (anchorless) double-row rotator cuff repair compared with double-row anchored (transosseous-equivalent [TOE]) repair. Methods: All patients undergoing double-row arthroscopic rotator cuff repair from 2009 to 2012 by a single surgeon were eligible for inclusion. The study included 2 consecutive series of patients undergoing anchorless or TOE repair. Excluded from the study were revision repairs, subscapularis repairs, patients with poor tendon quality or excursion requiring medialized repair, and partial repairs. Rotator cuff implant costs (paid by the institution) and surgical times were compared between the 2 groups, controlling for rotator cuff tear size and additional procedures performed. Results: The study included 344 patients, 178 with TOE repairs and 166 with anchorless repairs. Average implant cost for TOE repairs was $1014.10 ($813.00 for small, $946.67 for medium, $1104.56 for large, and $1507.29 for massive tears). This was significantly more expensive compared with anchorless repairs, which averaged $678.05 ($659.75 for small, $671.39 for medium, $695.55 for large, and $716.00 for massive tears). Average total operative time in TOE and anchorless groups was not significantly different (99 vs. 98 minutes). There was larger (although not statistically significant) case time variation in the TOE group. Conclusions: Compared with TOE repair, anchorless rotator cuff repair provides substantial implantrelated cost savings, with no significant differences in surgical time for medium and large rotator cuff tears. Case time for TOE repair varied more with extremes in tear size. (C) 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. All rights reserved.
引用
收藏
页码:1449 / 1456
页数:8
相关论文
共 50 条
  • [41] Biomechanical evaluation of an arthroscopic transosseous repair as a revision option for failed rotator cuff surgery
    Felix Dyrna
    Andreas Voss
    Leo Pauzenberger
    Elifho Obopilwe
    Augustus D. Mazzocca
    Alessandro Castagna
    Cory Edgar
    BMC Musculoskeletal Disorders, 19
  • [42] The rotator cuff tear repair with a new arthroscopic transosseous system: The Sharc-FT®
    Baudi P.
    Rasia Dani E.
    Campochiaro G.
    Rebuzzi M.
    Serafini F.
    Catani F.
    MUSCULOSKELETAL SURGERY, 2013, 97 (Suppl 1) : S57 - S61
  • [43] Factors influencing operative time in arthroscopic rotator cuff repair: a comparison of knotless single -row vs. transosseous equivalent dual -row techniques
    Boyd, Jason A.
    Karas, Spero G.
    Urchek, Ryan J.
    Farley, Kevin X.
    Anastasio, Albert T.
    Gottschalk, Michael B.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2020, 29 (07) : S48 - S52
  • [44] Arthroscopic transosseous suture anchor technique for rotator cuff repairs
    Cicak, N
    Klobucar, H
    Bicanic, G
    Trsek, D
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2006, 22 (05): : 565.e1 - 565.e6
  • [45] Arthroscopic Transosseous Anchorless Rotator Cuff Repair Using the X-Box Technique
    Steinitz, Amir
    Buxbaumer, Peter
    Hackl, Michael
    Buess, Eduard
    ARTHROSCOPY TECHNIQUES, 2019, 8 (02): : E175 - E181
  • [46] Biomechanical evaluation of an arthroscopic transosseous repair as a revision option for failed rotator cuff surgery
    Dyrna, Felix
    Voss, Andreas
    Pauzenberger, Leo
    Obopilwe, Elifho
    Mazzocca, Augustus D.
    Castagna, Alessandro
    Edgar, Cory
    BMC MUSCULOSKELETAL DISORDERS, 2018, 19
  • [47] Strength of fixation with transosseous sutures in rotator cuff repair
    Caldwell, GL
    Warner, JJP
    Miller, MD
    Boardman, D
    Towers, J
    Debski, R
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (07): : 1064 - 1068
  • [48] A novel transosseous button technique for rotator cuff repair
    Fox, Michael P.
    Auffarth, Alexander
    Tauber, Mark
    Hartmann, Andreas
    Resch, Herbert
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2008, 24 (09): : 1074 - 1077
  • [49] Technique and Outcomes for Knotless Transosseous Rotator Cuff Repair
    Savin, David D.
    Romeo, Anthony
    OPERATIVE TECHNIQUES IN SPORTS MEDICINE, 2018, 26 (01) : 2 - 9
  • [50] Arthroscopic rotator cuff techniques: single-row, double-row, and the transosseous equivalent
    Lutton, David M.
    Parsons, Bradford O.
    Flatow, Evan L.
    CURRENT ORTHOPAEDIC PRACTICE, 2009, 20 (04): : 349 - 354