The measurement of hemoglobin oxygen saturation using multi-wavelength photoacoustic microscopy

被引:0
|
作者
Deng, Zilin [1 ]
Yang, Xiaoquan [1 ]
Yu, Lejun [1 ]
Gong, Hui [1 ]
机构
[1] Huazhong Univ Sci & Technol, Britton Chance Ctr Biomed Photon, Wuhan Natl Lab Optoelect, Wuhan 430074, Peoples R China
关键词
multi-wavelength photoacoustic microscopy; hemoglobin oxygen saturation; TOMOGRAPHY; MECHANISMS;
D O I
10.1117/12.853222
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Hemoglobin oxygen saturation (SO2) is one of the most critical functional parameters to the metabolism. In this paper, we mainly introduced some initial results of measuring blood oxygen using multi-wavelength photoacoustic microscopy (PAM). In phantom study, we demonstrate the photoacoustic signal amplitude increases linearly with the concentration of red or blue ink. Then the calculated concentration of red ink in double-ink mixtures with PAM has a 5% difference with the result measured with spectrophotometric analysis. In ex vivo experiment, the measured result exhibt 15% difference between the PAM and spectrophotometric analysis. Experiment results suggest that PAM could be used to determine the SO2 quantitatively.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Effects of wavelength-dependent fluence attenuation on the noninvasive photoacoustic imaging of hemoglobin oxygen saturation in subcutaneous vasculature in vivo
    Maslov, Konstantin
    Zhang, Hao F.
    Wang, Lihong V.
    INVERSE PROBLEMS, 2007, 23 (06) : S113 - S122
  • [42] Monitor hemoglobin concentration and oxygen saturation in living mouse tail using Photoacoustic CT scanner
    Liu, Bo
    Kruger, Robert
    Reinecke, Daniel
    Stantz, Keith M.
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2010, 2010, 7564
  • [43] Characterization of excimer laser ablation generated pepsin particles using multi-wavelength photoacoustic instrument
    B. Hopp
    G. Kecskeméti
    T. Smausz
    T. Ajtai
    A. Filep
    N. Utry
    A. Kohut
    Z. Bozóki
    G. Szabó
    Applied Physics A, 2012, 107 : 429 - 435
  • [44] Characterization of excimer laser ablation generated pepsin particles using multi-wavelength photoacoustic instrument
    Hopp, B.
    Kecskemeti, G.
    Smausz, T.
    Ajtai, T.
    Filep, A.
    Utry, N.
    Kohut, A.
    Bozoki, Z.
    Szabo, G.
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2012, 107 (02): : 429 - 435
  • [45] Validating Hemoglobin Saturation and Dissolved Oxygen in Tumors Using Photoacoustic Computed Tomographic Spectroscopic Imaging
    Burnett, J.
    Sick, J.
    Cao, N.
    Liu, B.
    Nakshatri, H.
    Mendonca, M.
    Stantz, K.
    MEDICAL PHYSICS, 2016, 43 (06) : 3864 - 3864
  • [46] Multi-Wavelength Photoacoustic Visualization of High Intensity Focused Ultrasound Lesions
    Gray, J. P.
    Dana, N.
    Dextraze, K. L.
    Maier, F.
    Emelianov, S.
    Bouchard, R. R.
    ULTRASONIC IMAGING, 2016, 38 (01) : 96 - 112
  • [47] Measurement of temperature and wavelength-dependent emissivity distributions using multi-wavelength radiation thermometry
    Liu, Huawei
    Zheng, Shu
    OPTICS COMMUNICATIONS, 2020, 472
  • [48] Multi-wavelength lasers using AWGs
    den Besten, JH
    2003 IEEE LEOS ANNUAL MEETING CONFERENCE PROCEEDINGS, VOLS 1 AND 2, 2003, : 720 - 721
  • [49] Comment on "Measurement and correction of transverse chromatic offsets for multi-wavelength retinal microscopy in the living eye"
    Artal, Pablo
    BIOMEDICAL OPTICS EXPRESS, 2012, 3 (11): : 2772 - 2773
  • [50] Testing a Multi-Wavelength, Multi-Distance fNIR Probe as a Measure of Cerebral Oxygen Saturation for Use in a Feedback Titrated Oxygen Delivery System
    Verghese, Andrea
    Izzetoglu, Kurtulus
    Hamilton, Richard
    Barbee, Kenneth
    Ben Dor, Baruch
    Du, Juan
    2013 39TH ANNUAL NORTHEAST BIOENGINEERING CONFERENCE (NEBEC 2013), 2013, : 173 - 174