The measurement of hemoglobin oxygen saturation using multi-wavelength photoacoustic microscopy

被引:0
|
作者
Deng, Zilin [1 ]
Yang, Xiaoquan [1 ]
Yu, Lejun [1 ]
Gong, Hui [1 ]
机构
[1] Huazhong Univ Sci & Technol, Britton Chance Ctr Biomed Photon, Wuhan Natl Lab Optoelect, Wuhan 430074, Peoples R China
关键词
multi-wavelength photoacoustic microscopy; hemoglobin oxygen saturation; TOMOGRAPHY; MECHANISMS;
D O I
10.1117/12.853222
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Hemoglobin oxygen saturation (SO2) is one of the most critical functional parameters to the metabolism. In this paper, we mainly introduced some initial results of measuring blood oxygen using multi-wavelength photoacoustic microscopy (PAM). In phantom study, we demonstrate the photoacoustic signal amplitude increases linearly with the concentration of red or blue ink. Then the calculated concentration of red ink in double-ink mixtures with PAM has a 5% difference with the result measured with spectrophotometric analysis. In ex vivo experiment, the measured result exhibt 15% difference between the PAM and spectrophotometric analysis. Experiment results suggest that PAM could be used to determine the SO2 quantitatively.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Measurement of Multi-Wavelength Pulse Oxygen Saturation Based on Dynamic Spectroscopy
    Wang Xiao-fei
    Zhao Wen-jun
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2014, 34 (05) : 1323 - 1326
  • [2] In vivo detection of hemoglobin oxygen saturation and carboxyhemoglobin saturation variations with photoacoustic microscopy
    Chen, Zhongjiang
    Yang, Sihua
    Xing, Da
    OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS V, 2012, 8553
  • [3] In vivo detection of hemoglobin oxygen saturation and carboxyhemoglobin saturation with multiwavelength photoacoustic microscopy
    Chen, Zhongjiang
    Yang, Sihua
    Xing, Da
    OPTICS LETTERS, 2012, 37 (16) : 3414 - 3416
  • [4] Imaging of hemoglobin oxygen saturation variations in single vessels in vivo using photoacoustic microscopy
    Zhang, Hao F.
    Maslov, Konstantin
    Sivaramakrishnan, Mathangi
    Stoica, Gheorghe
    Wang, Lihong V.
    APPLIED PHYSICS LETTERS, 2007, 90 (05)
  • [5] 2 MHz multi-wavelength pulsed laser for functional photoacoustic microscopy
    Liang, Yizhi
    Jin, Long
    Guan, Bai-Ou
    Wang, Lidai
    OPTICS LETTERS, 2017, 42 (07) : 1452 - 1455
  • [6] The impact of the detection angle on the quantitative measurement of hemoglobin oxygen saturation in optical-resolution photoacoustic microscopy
    Wu, Ning
    Li, Changhui
    JOURNAL OF OPTICS, 2016, 18 (10)
  • [7] In vivo integrated photoacoustic and confocal microscopy of hemoglobin oxygen saturation and oxygen partial pressure
    Wang, Yu
    Hu, Song
    Maslov, Konstantin
    Zhang, Yu
    Xia, Younan
    Wang, Lihong V.
    OPTICS LETTERS, 2011, 36 (07) : 1029 - 1031
  • [8] Hybrid multi-wavelength photoacoustic imaging
    Duan, Tingyang
    Lan, Hengrong
    Zhong, Hongtao
    Zhou, Meng
    Zhang, Ruochong
    Gao, Fei
    2018 40TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2018, : 4804 - 4807
  • [9] In vitro photoacoustic measurement of hemoglobin oxygen saturation using a single pulsed broadband supercontinuum laser source
    Lee, Changho
    Jeon, Mansik
    Jeon, Min Yong
    Kim, Jeehyun
    Kim, Chulhong
    APPLIED OPTICS, 2014, 53 (18) : 3884 - 3889
  • [10] Reflection artifact identification in photoacoustic imaging using multi-wavelength excitation
    Nguyen, Ho Nhu Y.
    Hussain, Altaf
    Steenbergen, Wiendelt
    BIOMEDICAL OPTICS EXPRESS, 2018, 9 (10): : 4613 - 4630