Novel Protective Lead Shield and Pulse Fluoroscopy can Reduce Radiation Exposure during the ERCP Procedure

被引:16
|
作者
Kurihara, Toshio [1 ]
Ito, Takao [1 ]
Sofuni, Atsushi [1 ]
Itokawa, Fumihide [1 ]
Tsuchiya, Takayoshi [1 ]
Ishii, Kentaro [1 ]
Tsuji, Shujiro [1 ]
Ikeuchi, Nobuhito [1 ]
Moriyasu, Fuminori [1 ]
机构
[1] Tokyo Med Univ, Dept Gastroenterol & Hepatol, Shinjuku Ku, Tokyo 1600023, Japan
关键词
Radiation exposure; ERCP; Lead shield; CARDIAC-CATHETERIZATION; PERSONNEL;
D O I
10.5754/hge11764
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background/Aims: ERCP-related procedures involve radiation exposure of patients and medical staff. We developed a novel protective lead shield which is attached around the fluoroscopy generator. Here we examine levels of radiation exposure to patients, endoscopists and assistants, and evaluate the usefulness of the newly designed protective shield. Methodology: Four-hundred and seventy-one ERCP procedures were performed from April 2006 to April 2007. At first, we compared the radiation dose of consecutive fluoroscopy conditions with pulse fluoroscopy of 15 per second and then the radiation dose with and without the protective shield. Next, we measured the radiation exposure of endoscopists and assistants in the clinical setting monitored by digital dosimeter during ERCP procedure. Results: The radiation dose was the most at the 45 direction. Using pulse fluoroscopy of 15 per second the radiation dose of patients and endoscopists decreased by about half. Using both pulse fluoroscopy of 15 per second and the protective shield, the radiation dose at the endoscopist's position was reduced up to 97%. The total fluoroscopy time was 5851 minutes in the 471 ERCP cases. Using pulse 15 and the protective lead shield, the radiation exposure dose of one endoscopist and two assistants were 2430.8, 2673.9 and 1375.0 mu Sv, respectively. Conclusions: Novel protective lead shield in combination with pulse fluoroscopy can significantly reduce the radiation exposure leading to avoid unnecessary radiation exposure to patients and medical staff.
引用
收藏
页码:709 / 712
页数:4
相关论文
共 50 条
  • [1] Novel protective lead shield and pulse fluoroscopy can radiation exposure during the ERCP procedure
    Kurihara, T.
    Itoi, T.
    Sofuni, A.
    Itokawa, F.
    Ishii, K.
    Tsuchiya, T.
    Ikeuchi, N.
    Umeda, J.
    Tanaka, R.
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2011, 26 : 230 - 230
  • [2] Can we reduce the radiation exposure during ERCP procedure by using a novel protective lead shield?
    Kurihara, Toshio
    Itoi, Takao
    Sofuni, Atsushi
    Itokawa, Fumihide
    Tsuji, Shujiro
    Ishii, Kentarou
    Ikeuchi, Nobuhito
    Moriyasu, Fuminori
    GASTROINTESTINAL ENDOSCOPY, 2008, 67 (05) : AB234 - AB234
  • [3] Radiation exposure during ERCP: Effect of a protective shield
    Chen, MYM
    VanSwearingen, FL
    Mitchell, R
    Ott, DJ
    GASTROINTESTINAL ENDOSCOPY, 1996, 43 (01) : 1 - 5
  • [4] Low fluoroscopy pulse rates as a mean to reduce radiation exposure during neuroendovascular procedure
    Gailloud, Philippe
    INTERVENTIONAL NEURORADIOLOGY, 2021, 27 (02) : 321 - 321
  • [5] Pulse Fluoroscopy in ERCP: Reducing Radiation Exposure
    Singhal, Amit
    Rowe, Gillian
    Faizallah, Riyaz
    GASTROINTESTINAL ENDOSCOPY, 2006, 63 (05) : AB300 - AB300
  • [6] Pulsed Fluoroscopy to Reduce Radiation Exposure During ERCP: A Prospective Randomized Trial
    Uradomo, Lance T.
    Goldberg, Eric M.
    Darwin, Peter E.
    GASTROINTESTINAL ENDOSCOPY, 2006, 63 (05) : AB104 - AB104
  • [7] Time-limited fluoroscopy to reduce radiation exposure during ERCP: a prospective randomized trial
    Uradomo, Lance T.
    Goldberg, Eric M.
    Darwin, Peter E.
    GASTROINTESTINAL ENDOSCOPY, 2007, 66 (01) : 84 - 89
  • [8] Minimizing Radiation Exposure During ERCP by Avoiding Live or Continuous Fluoroscopy
    Churrango, Gustavo
    Deutsch, Jill K.
    Dinneen, Henry S.
    Churrango, Jose
    Samiullah, Sami
    Ahlawat, Sushil K.
    JOURNAL OF CLINICAL GASTROENTEROLOGY, 2015, 49 (10) : E96 - E100
  • [9] Correlation between fluoroscopy time and personnel radiation exposure during ERCP.
    Vandervoort, J
    Tham, TCK
    Wong, RCK
    Cialfi, SA
    CarrLocke, DL
    GASTROINTESTINAL ENDOSCOPY, 1996, 43 (04) : 127 - 127
  • [10] MAPPING RADIATION EXPOSURE LEVELS DURING A SIMULATED ERCP PROCEDURE
    VANSWEARINGEN, FL
    MITCHELL, RG
    CHEN, MYM
    OTT, DJ
    GELFAND, DW
    GASTROINTESTINAL ENDOSCOPY, 1993, 39 (02) : 325 - 325