Cerebral blood flow volume measurements of the carotid artery and ipsilateral branches using two-dimensional phase-contrast magnetic resonance angiography

被引:2
|
作者
Guo, Gang [1 ]
Yang, Yonggui [1 ]
Yang, Weiqun [1 ]
机构
[1] Fujian Med Univ, Dept Radiol, Xiamen Hosp 2, Teaching Hosp, Xiamen 361021, Fujian Province, Peoples R China
关键词
two-dimensional phase-contrast magnetic resonance angiography; blood flow; three-dimensional time-of-flight phase-contrast magnetic resonance angiography; internal carotid artery; common carotid artery; external carotid artery; velocity encoding; TIME-OF-FLIGHT; MR-ANGIOGRAPHY; INTRACRANIAL VESSELS; CEREBROSPINAL-FLUID; HYPERTENSION; MORPHOLOGY; ACCURACY; BRAIN; AORTA; AGE;
D O I
10.3969/j.issn.1673-5374.2011.30.009
中图分类号
Q2 [细胞生物学];
学科分类号
071009 ; 090102 ;
摘要
The optimal velocity encoding of phase-contrast magnetic resonance angiography (PC MRA) in measuring cerebral blood flow volume (BFV) ranges from 60 to 80 cm/s. To verify the accuracy of two-dimensional (2D) PC MRA, the present study localized the region of interest at blood vessels of the neck using PC MRA based on three-dimensional time-of-flight sequences, and the velocity encoding was set to 80 cm/s. Results of the measurements showed that the error rate was 7.0 +/- 6.0% in the estimation of BFV in the internal carotid artery, the external carotid artery and the ipsilateral common carotid artery. There was no significant difference, and a significant correlation in BFV between internal carotid artery + external carotid artery and ipsilateral common carotid artery. In addition, the BFV of the common carotid artery was correlated with that of the ipsilateral internal carotid artery. The main error was attributed to the external carotid artery and its branches. Therefore, after selecting the appropriate scanning parameters and protocols, 2D PC MRA is more accurate in the determination of BFV in the carotid arteries.
引用
收藏
页码:2367 / 2371
页数:5
相关论文
共 50 条
  • [2] Phase-Contrast Magnetic Resonance Angiography Measurements of Global Cerebral Blood Flow in the Neonate
    Benders, Manon J. N. L.
    Hendrikse, Jeroen
    de Vries, Linda S.
    van Bel, Frank
    Groenendaal, Floris
    PEDIATRIC RESEARCH, 2011, 69 (06) : 544 - 547
  • [3] Phase-Contrast Magnetic Resonance Angiography Measurements of Global Cerebral Blood Flow in the Neonate
    Manon J N L Benders
    Jeroen Hendrikse
    Linda S de Vries
    Frank van Bel
    Floris Groenendaal
    Pediatric Research, 2011, 69 : 544 - 547
  • [4] Optimal velocity encoding during measurement of cerebral blood flow volume using phase-contrast magnetic resonance angiography
    Guo, Gang
    Yang, Yonggui
    Yang, Weiqun
    NEURAL REGENERATION RESEARCH, 2011, 6 (23) : 1796 - 1800
  • [6] Perioperative evaluation of blood volume flow in high-flow cerebral arteriovenous malformation using phase-contrast magnetic resonance angiography
    Yamada, Shigeki
    Watanabe, Yoshihiko
    Oshima, Marie
    Miyake, Hidenori
    INTERDISCIPLINARY NEUROSURGERY-ADVANCED TECHNIQUES AND CASE MANAGEMENT, 2015, 2 (02): : 72 - 75
  • [7] Doppler-Assessed Cerebral Blood Flow Velocity in the Neonate as Estimator of Global Cerebral Blood Volume Flow Measured Using Phase-Contrast Magnetic Resonance Angiography
    Benders, Manon J. N. L.
    Hendrikse, Jeroen
    de Vries, Linda
    Groenendaal, Floris
    van Bel, Frank
    NEONATOLOGY, 2013, 103 (01) : 21 - 26
  • [8] Cerebral Blood Flow Measured by Phase-Contrast Magnetic Resonance Angiography in Preterm and Term Neonates
    Wagenaar, Nienke
    Rijsman, Lucas H.
    Nieuwets, Astrid
    Groenendaal, Floris
    Benders, Manon
    de Vries, Linda S.
    Dijkhorst, Annefleur
    Francovich, Juliette
    Freriks, Anouk
    Gerbens, Anna
    van Hoef, Noortje
    Van Lent, Maud
    Vrins, Carlijn
    NEONATOLOGY, 2019, 115 (03) : 226 - 233
  • [9] The effect of hyperoxia on cerebral blood flow: a study in healthy volunteers using magnetic resonance phase-contrast angiography
    Watson, NA
    Beards, SC
    Altaf, N
    Kassner, A
    Jackson, A
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2000, 17 (03) : 152 - 159
  • [10] Effect of age on cerebral blood flow: Measurement with ungated two-dimensional phase-contrast MR angiography in 250 adults
    Buijs, PC
    Krabbe-Hartkamp, MJ
    Bakker, CJG
    de Lange, EE
    Ramos, LMP
    Breteler, MMB
    Mali, WPTM
    RADIOLOGY, 1998, 209 (03) : 667 - 674