Design of the high field side antenna of the new reflectometric system for plasma position estimate in RFXmod2

被引:1
|
作者
Marchiori, G. [1 ]
Cavazzana, R. [1 ]
De Masi, G. [1 ]
Moresco, M. [1 ]
机构
[1] Univ Padua, Consorzio RFX, CNR, Ist Nazl Fis Nucl,ENEA,Acciaierie Venete SpA, Corso Stati Uniti 4, I-35127 Padua, Italy
来源
JOURNAL OF INSTRUMENTATION | 2022年 / 17卷 / 01期
关键词
Microwave Antennas; Models and simulations; Plasma diagnostics - probes;
D O I
10.1088/1748-0221/17/01/C01002
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A reflectometric system will be installed in the RFX-mod2 experiment, consisting of 4 couples of transmitting/receiving antennas working in the range 16-26.5 GHz in X-mode wave propagation for tokamak discharges. They will be placed within dedicated plasma accesses in the same poloidal section at 4 equispaced poloidal positions, two on the equatorial plane, High Field Side (HFS)/Low Field Side (LFS), and two at the vertical top/bottom ports. This configuration was conceived to perform plasma position control experiments without using the magnetic measurement signals. While the accesses in LFS, top and bottom positions will accommodate pyramidal antennas, the strict room constraints in the HFS position required a special routing of the feeding waveguide and the design of a different type of antenna, described in the paper. The horn reflector (also named hoghorn) type was preferred which allows radiating (and receiving) a beam at a 90 degrees direction with respect to the horn axis, which will be perpendicular to the equatorial plane. After fixing a reference working frequency f = 21 GHz (wavelength lambda = 14.3 mm), an antenna fitting the available room was designed by means of the COMSOL Multiphysics Radio Frequency module. Four different versions were developed by introducing some modifications of the aperture shape to study their effect on the antenna performance. FEM analyses were run for frequencies in the 17-26 GHz interval to characterize the frequency response in terms of radiative patterns of the total and far electric field. The directivity of the antennae was also evaluated. The 4 versions exhibited comparable responses and the observed beam directional properties at the expected plasma distance were considered acceptable for the development of this application. A prototype of the antenna has been realized by additive manufacturing process.
引用
收藏
页数:12
相关论文
共 37 条
  • [31] Propose a New Distance Degradation Parameter to Estimate Level of Out-Of-Band Emission Caused by Non-linear High Power Amplifiers for DVB-S2 System
    Doan Thanh Hai
    Nguyen Van Vinh
    Nguyen Tat Nam
    Nguyen Quoc Binh
    Dao Huy Du
    ADVANCES IN ENGINEERING RESEARCH AND APPLICATION, 2019, 63 : 504 - 512
  • [32] High sensitive LOCI based F 1+2 immunoassay for quantification of prothrombin fragment 1+2 in human plasma samples on the new INNOVANCE BCS LT system
    Ehm, M.
    Kraul, D.
    Stangl, A.
    Pfeiff, M.
    Feddersen, L.
    Smith, V
    Duwe, C.
    Kuhn, U.
    Pohlack-Marsch, O.
    Vesper, P.
    Boucsein-Mueller, E.
    Poetzsch, B.
    Zander, N.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2016, 14 : 128 - 128
  • [33] New inductively coupled plasma-chemical vapor deposition SiO2 passivation for high-voltage switching AlGaN/GaN heterostructure field-effect transistors
    Ha, Min-Woo
    Lee, Seung-Chul
    Her, Jin-Cherl
    Sec, Kwang-Seok
    Han, Min-Koo
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2006, 45 (4B): : 3391 - 3394
  • [34] New inductively coupled plasma-chemical vapor deposition SiO2 passivation for high-voltage switching AlGaN/GaN heterostructure field-effect transistors
    Ha, Min-Woo
    Lee, Seung-Chul
    Her, Jin-Cherl
    Seo, Kwang-Seok
    Han, Min-Koo
    Japanese Journal of Applied Physics, Part 1: Regular Papers and Short Notes and Review Papers, 2006, 45 (4 B): : 3391 - 3394
  • [35] Performance of the new Aptima HCV quant Dx assay in comparison to the Cobas TaqMan HCV2 assay for use with the high pure system in the detection and quantification of HCV RNA in plasma or serum
    Schalasta, G.
    Speicher, A.
    Boerner, A.
    Enders, M.
    JOURNAL OF CLINICAL VIROLOGY, 2016, 82 : S71 - S72
  • [36] Development of a new lapping method for high precision ball screw (2nd report) - Design and experimental study of an automatic lapping machine with in-process torque monitoring system
    Guevarra, DS
    Kyusojin, A
    Isobe, H
    Kaneko, Y
    PRECISION ENGINEERING-JOURNAL OF THE INTERNATIONAL SOCIETIES FOR PRECISION ENGINEERING AND NANOTECHNOLOGY, 2002, 26 (04): : 389 - 395
  • [37] Performance of the New Aptima HCV Quant Dx Assay in Comparison to the Cobas TaqMan HCV2 Test for Use with the High Pure System in Detection and Quantification of Hepatitis C Virus RNA in Plasma or Serum
    Schalasta, Gunnar
    Speicher, Andrea
    Boerner, Anna
    Enders, Martin
    JOURNAL OF CLINICAL MICROBIOLOGY, 2016, 54 (04) : 1101 - 1107