Comparison of optical coherence tomography and scanning laser polarimetry in glaucoma, ocular hypertension, and suspected glaucoma

被引:4
|
作者
Halkiadakis, Oannis [1 ]
Kipioti, Athina [2 ]
Emfietzoglou, Ioannis [2 ]
Grigoropoulos, Vlassis [2 ]
Katsis, Athanasios [2 ]
Alimisi, Sotiria [2 ]
Vergados, Ioannis [3 ]
Theodossiadis, Panagiotis [3 ]
Theodossiadis, George P. [2 ]
机构
[1] Athens Eye Hosp, Athens, Greece
[2] Henry Dunant Hosp, Dept Ophthalmol 2, Athens, Greece
[3] Univ Athens, Dept Ophthalmol 2, Athens, Greece
关键词
D O I
10.3928/15428877-20080301-09
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
BACKGROUND AND OBJECTIVE: To compare the performance of the newest generation optical coherence topography (OCT) and scanning laser polarimetry with variable corneal compensation (SLP-VCC) in eyes with glaucoma, ocular hypertension, and suspected glaucoma. PATIENTS AND METHODS: One eye each of 84 patients (30 with glaucoma, 26 with suspected glaucoma, and 28 with ocular hypertension) was included in the study. Retinal nerve fiber layer (RNFL) thickness was measured with both technologies and thickness parameters were compared in the three groups of eyes. The correspondence of RNFL thickness measurements with visual field function was also studied. RESULTS: Average OCT-RNFL thickness was found to have a statistically significant difference between patients with glaucoma and either suspected glaucoma or ocular hypertension. A statistically significant correlation between the average RNFL thicknesses measured by the two different technologies was shown only in the glaucoma group. A significant correlation with visual field mean deviation was found for superior average RNFL thickness as measured by SLP and for nerve fiber indicator and average and inferior average RNFL thickness as measured by OCT in glaucomatous eyes. Regression analysis indicated nerve fiber indicator to be the most valuable factor in predicting mean deviation. CONCLUSION: RNFL thickness measurements obtained with OCT and SLP-VCC correlate well only in eyes with more advanced glaucomatous damage. The nerve fiber indicator parameter derived by SLP correlated best with mean deviation.
引用
收藏
页码:125 / 132
页数:8
相关论文
共 50 条
  • [31] Evaluation of spectral domain optical coherence tomography parameters in ocular hypertension, preperimetric, and early glaucoma
    Aydogan, Tugba
    Akcay, Betul Ilkay Sezgin
    Kardes, Esra
    Ergin, Ahmet
    [J]. INDIAN JOURNAL OF OPHTHALMOLOGY, 2017, 65 (11) : 1143 - 1150
  • [32] Longitudinal evaluation of scanning laser polarimetry in glaucoma
    Khong, CH
    Waldock, A
    Diamond, JP
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S838 - S838
  • [33] Accuracy of scanning laser polarimetry in the diagnosis of glaucoma
    Trible, JR
    Schultz, RO
    Robinson, JC
    Rothe, TL
    [J]. ARCHIVES OF OPHTHALMOLOGY, 1999, 117 (10) : 1298 - 1304
  • [34] Comparison of Different Spectral Domain Optical Coherence Tomography Scanning Areas for Glaucoma Diagnosis
    Rao, Harsha L.
    Zangwill, Linda M.
    Weinreb, Robert N.
    Sample, Pamela A.
    Alencar, Luciana M.
    Medeiros, Felipe A.
    [J]. OPHTHALMOLOGY, 2010, 117 (09) : 1692 - U55
  • [35] Ability of retinal nerve fiber layer measurements of spectral domain optical coherence tomography and scanning laser polarimetry to diagnose preperimetric glaucoma
    Rao, Harsha L.
    Yadav, Ravi K.
    Addepalli, Uday
    Chaudhary, Shashikant
    Senthil, Sirisha
    Choudhari, Nikhil S.
    Garudadri, Chandra S.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [36] Peripapillary Retinal Nerve Fiber Layer Assessment of Spectral Domain Optical Coherence Tomography and Scanning Laser Polarimetry to Diagnose Preperimetric Glaucoma
    Rao, Harsha L.
    Yadav, Ravi K.
    Addepalli, Uday K.
    Chaudhary, Shashikant
    Senthil, Sirisha
    Choudhari, Nikhil S.
    Garudadri, Chandra S.
    [J]. PLOS ONE, 2014, 9 (10):
  • [37] Comparison of Optical Coherence Tomography and Scanning Laser Polarimetry Measurements in Patients with Multiple Sclerosis
    Quelly, Amanda
    Cheng, Han
    Laron, Michal
    Schiffman, Jade S.
    Tang, Rosa A.
    [J]. OPTOMETRY AND VISION SCIENCE, 2010, 87 (08) : 576 - 584
  • [38] Comparison Between Swept-Source and Spectral-Domain Optical Coherence Tomography Angiography in Ocular Hypertension and Glaucoma
    Lun, Katherine
    Tan, Bingyao
    Sng, Chelvin
    Schmetterer, Leopold
    Chua, Jacqueline
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2022, 63 (07)
  • [39] Comparison of scanning laser polarimetry and polarization sensitive spectral domain optical coherence tomography
    Goetzinger, Erich
    Pircher, Michael
    Baumann, B.
    Vass, Clemens
    Hitzenberger, Christoph K.
    [J]. OPHTHALMIC TECHNOLOGIES XVII, 2007, 6426
  • [40] Comparison of Pattern Electroretinography and Optical Coherence Tomography Parameters in Patients with Primary Open-Angle Glaucoma and Ocular Hypertension
    Demir, Semra Tiryaki
    Oba, Mehmet Ersin
    Erdogan, Ezgi Tuna
    Odabasi, Mahmut
    Dirim, Aye Burcu
    Demir, Mehmet
    Can, Efe
    Kara, Orhan
    Sendul, Selam Yekta
    [J]. TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2015, 45 (06): : 229 - 234