Reliability and Validity of IMU-Based Foot Progression Angle Measurement under Different Gait Retraining Strategies

被引:4
|
作者
Urbanus, Francine C. A. [1 ]
Grayson, Jane [2 ]
Harlaar, Jaap [1 ,3 ]
Simic, Milena [2 ]
机构
[1] Delft Univ Technol, Dept BioMech Engn, NL-2628 CD Delft, Netherlands
[2] Univ Sydney, Fac Med & Hlth, Discipline Physiotherapy, Sydney, NSW 2006, Australia
[3] Erasmus MC, Dept Orthoped, NL-3015 GD Rotterdam, Netherlands
来源
APPLIED SCIENCES-BASEL | 2022年 / 12卷 / 13期
关键词
gait analysis; foot progression angle; APDM; inertial measurement unit; toe-in; toe-out; PAIN;
D O I
10.3390/app12136519
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Load modifying gait retraining strategies, such as changing the foot progression angle (FPA) to toe-in and toe-out gait, are used for people with medial knee osteoarthritis. The FPA can be measured using a pressure sensitive walkway (PSW), but inertial measurement units (IMUs) are considered more suitable for clinical use. This study evaluated the reliability and validity of an IMU system, to measure FPA under different gait retraining strategies. Twenty healthy participants walked a 10-m-long path using different gait strategies (natural (2), toe-out gait (1), toe-in gait (1)) during four 90-s trials. FPA was measured simultaneously with IMUs and a PSW, the latter considered the reference standard. There was good and excellent reliability for the IMUs and PSW FPA measurements, respectively (ICC: IMU, 0.89; PSW, 0.97). Minimal detectable change (MDC) was 4.5 degrees for the IMUs and 2.7 degrees for the PSW. Repeated measures ANOVA indicated a significant effect of gait type on FPA (p < 0.001), but not the measurement instrument (p = 0.875). Bland-Altman plots demonstrated the good agreement of both systems for the baseline condition, though the IMUs seemed to consistently overestimate the FPA value compared to the PSW. In conclusion, IMUs are a reliable and valid measurement system for measuring FPA under different gait retraining strategies. The differences between the systems are significant for all gait strategies, so the systems should not be used interchangeably.
引用
收藏
页数:10
相关论文
共 27 条
  • [21] Verification of Reliability and Validity of Trunk Forward Tilt Angle Measurement During Gait Using 2-Dimensional Motion Analysis
    Iijima, Shinno
    Shiomi, Makoto
    Hara, Tsuyoshi
    JOURNAL OF CHIROPRACTIC MEDICINE, 2023, 22 (02) : 89 - 95
  • [22] Accuracy, concurrent validity, and test-retest reliability of pressure-based insoles for gait measurement in chronic stroke patients
    Neumann, Saskia
    Bauer, Christoph M.
    Nastasi, Luca
    Laderach, Julia
    Thurlimann, Eva
    Schwarz, Anne
    Held, Jeremia P. O.
    Easthope, Chris A.
    FRONTIERS IN DIGITAL HEALTH, 2024, 6
  • [23] Reliability, Validity, and Identification Ability of a Commercialized Waist-Attached Inertial Measurement Unit (IMU) Sensor-Based System in Fall Risk Assessment of Older People
    Li, Ke-Jing
    Wong, Nicky Lok-Yi
    Law, Man-Ching
    Lam, Freddy Man-Hin
    Wong, Hoi-Ching
    Chan, Tsz-On
    Wong, Kit-Naam
    Zheng, Yong-Ping
    Huang, Qi-Yao
    Wong, Arnold Yu-Lok
    Kwok, Timothy Chi-Yui
    Ma, Christina Zong-Hao
    BIOSENSORS-BASEL, 2023, 13 (12):
  • [24] A comprehensive study on reliability performance of Photovoltaic-battery-based microgrids under different energy management strategies
    Jiang, Jiahui
    Peyghami, Saeed
    Coates, Colin
    Blaabjerg, Frede
    JOURNAL OF ENERGY STORAGE, 2021, 43
  • [25] Reliability and criterion validity of measurements using a smart phone-based measurement tool for the transverse rotation angle of the pelvis during single-leg lifting
    Jung, Sung-hoon
    Kwon, Oh-yun
    Jeon, In-cheol
    Hwang, Ui-jae
    Weon, Jong-hyuck
    PHYSIOTHERAPY THEORY AND PRACTICE, 2018, 34 (01) : 58 - 65
  • [26] Performance Evaluation of a Guarded Hot Box U-value Measurement Facility under Different Software Based Temperature Control Strategies
    Ghosh, Amrita
    Ghosh, Supratik
    Neogi, Subhasis
    4 INTERNATIONAL CONFERENCE ON ADVANCES IN ENERGY RESEARCH (ICAER 2013), 2014, 54 : 448 - 454
  • [27] Simultaneous Validity and Intra-Test Reliability of Joint Angle Measurement through Novel Multi-RGB Sensor-Based Three-Joint-Continuous-Motion Analysis: A Pilot Study
    Ahn, Junghoon
    Choi, Hongtaek
    Lee, Heehwa
    Kim, Suhng Wook
    Lee, Jinyoung
    Kim, Hyeong-Dong
    APPLIED SCIENCES-BASEL, 2024, 14 (01):