Reliability and Validity of IMU-Based Foot Progression Angle Measurement under Different Gait Retraining Strategies

被引:4
|
作者
Urbanus, Francine C. A. [1 ]
Grayson, Jane [2 ]
Harlaar, Jaap [1 ,3 ]
Simic, Milena [2 ]
机构
[1] Delft Univ Technol, Dept BioMech Engn, NL-2628 CD Delft, Netherlands
[2] Univ Sydney, Fac Med & Hlth, Discipline Physiotherapy, Sydney, NSW 2006, Australia
[3] Erasmus MC, Dept Orthoped, NL-3015 GD Rotterdam, Netherlands
来源
APPLIED SCIENCES-BASEL | 2022年 / 12卷 / 13期
关键词
gait analysis; foot progression angle; APDM; inertial measurement unit; toe-in; toe-out; PAIN;
D O I
10.3390/app12136519
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Load modifying gait retraining strategies, such as changing the foot progression angle (FPA) to toe-in and toe-out gait, are used for people with medial knee osteoarthritis. The FPA can be measured using a pressure sensitive walkway (PSW), but inertial measurement units (IMUs) are considered more suitable for clinical use. This study evaluated the reliability and validity of an IMU system, to measure FPA under different gait retraining strategies. Twenty healthy participants walked a 10-m-long path using different gait strategies (natural (2), toe-out gait (1), toe-in gait (1)) during four 90-s trials. FPA was measured simultaneously with IMUs and a PSW, the latter considered the reference standard. There was good and excellent reliability for the IMUs and PSW FPA measurements, respectively (ICC: IMU, 0.89; PSW, 0.97). Minimal detectable change (MDC) was 4.5 degrees for the IMUs and 2.7 degrees for the PSW. Repeated measures ANOVA indicated a significant effect of gait type on FPA (p < 0.001), but not the measurement instrument (p = 0.875). Bland-Altman plots demonstrated the good agreement of both systems for the baseline condition, though the IMUs seemed to consistently overestimate the FPA value compared to the PSW. In conclusion, IMUs are a reliable and valid measurement system for measuring FPA under different gait retraining strategies. The differences between the systems are significant for all gait strategies, so the systems should not be used interchangeably.
引用
收藏
页数:10
相关论文
共 27 条
  • [1] IMU-Based Joint Angle Measurement for Gait Analysis
    Seel, Thomas
    Raisch, Joerg
    Schauer, Thomas
    SENSORS, 2014, 14 (04) : 6891 - 6909
  • [2] Validity and reliability of an IMU-based method to detect APAs prior to gait initiation
    Mancini, Martina
    Chiari, Lorenzo
    Holmstrom, Lars
    Salarian, Arash
    Horak, Fay B.
    GAIT & POSTURE, 2016, 43 : 125 - 131
  • [3] Reliability testing of an IMU-based 2-segment foot model for clinical gait analysis
    Bauer, Leandra
    Hamberger, Maximilian Anselm
    Boecker, Wolfgang
    Polzer, Hans
    Baumbach, Sebastian Felix
    GAIT & POSTURE, 2024, 114 : 112 - 118
  • [4] Reliability of IMU-Based Gait Assessment in Clinical Stroke Rehabilitation
    Felius, Richard A. W.
    Geerars, Marieke
    Bruijn, Sjoerd M.
    van Dieen, Jaap H.
    Wouda, Natasja C.
    Punt, Michiel
    SENSORS, 2022, 22 (03)
  • [5] Plug-and-Play IMU-Based Gait Measurement: Toward 3-D Foot Angle Estimation for KOA Patients
    Wang, Zhengtao
    Ding, Yuantao
    Luo, Baiqing
    Xue, Bin
    Zhang, Jinlin
    Huang, Ping
    Wang, Dongmei
    Yu, Suiran
    IEEE SENSORS JOURNAL, 2025, 25 (04) : 7345 - 7354
  • [6] IMU-Based Kinematics Estimation Accuracy Affects Gait Retraining Using Vibrotactile Cues
    Rokhmanova, Nataliya
    Pearl, Owen
    Kuchenbecker, Katherine J.
    Halilaj, Eni
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2024, 32 : 1005 - 1012
  • [7] Examination of a foot mounted IMU-based methodology for a running gait assessment
    Young, Fraser
    Mason, Rachel
    Wall, Conor
    Morris, Rosie
    Stuart, Samuel
    Godfrey, Alan
    FRONTIERS IN SPORTS AND ACTIVE LIVING, 2022, 4
  • [8] Development of IMU-Based Angle Measurement System for Finger Rehabilitation
    Chang, Hsien-Ting
    Cheng, Li-Wei
    Chang, Jen-Yuan
    PROCEEDINGS OF 2016 23RD INTERNATIONAL CONFERENCE ON MECHATRONICS AND MACHINE VISION IN PRACTICE (M2VIP), 2016, : 196 - 201
  • [9] Magnetometer-Free, IMU-Based Foot Progression Angle Estimation for Real-Life Walking Conditions
    Tan, Tian
    Strout, Zachary A.
    Xia, Haisheng
    Orban, Mostafa
    Shull, Peter B.
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2021, 29 : 282 - 289
  • [10] A Novel Foot-Forward Segmentation Algorithm for Improving IMU-Based Gait Analysis
    Ruiz-Ruiz, Luisa
    Garcia-Dominguez, Juan Jesus
    Jimenez, Antonio R.
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2024, 73