Poly (naphthol green B) modified carbon paste electrode sensor for catechol and hydroquinone

被引:32
|
作者
Kuskur, Chethan M. [1 ]
Swamy, B. E. Kumara [1 ]
Jayadevappa, H. [2 ]
机构
[1] Kuvempu Univ, Dept PG Studies & Res Ind Chem, Shimoga 577451, Karnataka, India
[2] Sahyadri Sci Coll, Dept Chem, Shimoga 577203, Karnataka, India
关键词
Catechol; Hydroquinone; Naphthol green B; Cyclic voltammetry; Electropolymerisation; Carbon paste electrode; SIMULTANEOUS ELECTROCHEMICAL DETERMINATION; ASCORBIC-ACID; ELECTROCATALYTIC OXIDATION; VOLTAMMETRIC DETERMINATION; SELECTIVE DETERMINATION; PHENOLIC-COMPOUNDS; REDUCED GRAPHENE; BINARY-MIXTURES; URIC-ACID; FILM;
D O I
10.1016/j.jelechem.2017.09.039
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple and highly sensitive electrochemical method for the simultaneous and quantitative determination of catechol (CC) and hydroquinone (HQ) were developed based on the poly (Naphthol green B) modified carbon paste electrode. The modified electrode showed outstanding electrocatalytic activity and reversibility towards the oxidation of two phenolic isomers of Catechol (CC) and Hydroquinone (HQ) were performed at poly (NG B) MCPE by cyclic voltammetry in 0.2 M phosphate buffer solution of pH 7.4 at sweep rate 100 mV/s. Several factors affecting the electrochemical parameters, like the effect of sweep rate, pH and different concentration of both CC and HQ were studied. The simulations determination of CC and HQ in their sample mixture was analysed by using the cyclic voltammetric technique. The differences of the oxidation peak potentials for CC-HQ were about 0.124 V in cyclic voltammetry at 100 mV/s respectively. The interference studies showed that the modified electrode exhibits excellent selectivity. The detection limits were 0.19 and 0.20 mu M (20 to 90 mu M) for CC and HQ, respectively. Finally, this method can be used in the development of a sensor for sensitive determination of CC and HQ.
引用
收藏
页码:99 / 106
页数:8
相关论文
共 50 条
  • [41] Direct simultaneous electrochemical determination of hydroquinone and catechol at a poly(glutamic acid) modified glassy carbon electrode
    Wang, Liang
    Huang, Pengfei
    Bai, Junyue
    Wang, Hongjing
    Zhang, Liying
    Zhao, Yuqing
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2007, 2 (01): : 123 - 132
  • [42] Poly (safranine) modified carbon paste electrode as a sensor for the determination of fenitrothion pesticide
    El-Hallag, Ibrahim Shibl
    Moharram, Youssef Ibrahim
    Selim, Sameh Mahmoud
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [43] Poly (safranine) modified carbon paste electrode as a sensor for the determination of fenitrothion pesticide
    Ibrahim Shibl El-Hallag
    Youssef Ibrahim Moharram
    Sameh Mahmoud Selim
    Scientific Reports, 13
  • [44] Electrocatalytic response of hydroquinone and catechol at polyglycine modified glassy carbon electrode
    Wang, Liang
    Huang, Pengfei
    Wang, Hongjing
    Bai, Junyue
    Zhang, Liying
    Zhao, Yuqing
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2007, 2 (03): : 216 - 225
  • [45] A new sensing platform based on poly(valine)-modified carbon paste electrode for the determination of hydroquinone and resorcinol
    Moulya, K. P.
    Manjunatha, J. G.
    Almutairi, Tahani Mazyad
    Nagaraja, M.
    Somashekara, B.
    MONATSHEFTE FUR CHEMIE, 2024, 155 (07): : 673 - 682
  • [46] Enhancing of hydroquinone and catechol oxidation using a graphite and graphene composite polymer modified paste electrode
    Bhimaraya, Kanthappa
    Manjunatha, J. G.
    Almutairi, Tahani Mazyad
    Ataollahi, Narges
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2024,
  • [47] Comparative investigation on electrochemical behavior of hydroquinone at carbon ionic liquid electrode, ionic liquid modified carbon paste electrode and carbon paste electrode
    Zhang, Ya
    Zheng, Jian Bin
    ELECTROCHIMICA ACTA, 2007, 52 (25) : 7210 - 7216
  • [48] Simultaneous determination of hydroquinone and catechol at a glassy carbon electrode modified with multiwall carbon nanotubes
    Qi, HL
    Zhang, CX
    ELECTROANALYSIS, 2005, 17 (10) : 832 - 838
  • [49] Simultaneous electrochemical detection of hydroquinone and catechol in binary mixtures using poly(cysteine)-modified glassy carbon electrode
    Wang, Liang
    Huang, Pengfei
    Bai, Junyue
    Wu, Xiaowei
    Wang, Hongjing
    Zhao, Yuqing
    CHEMIA ANALITYCZNA, 2007, 52 (01): : 15 - 24
  • [50] Simultaneous determination of hydroquinone and catechol Using poly(p-aminobenzoic acid) modified glassy carbon electrode
    Yang, Ping
    Zhu, Qiyong
    Chen, Yonghong
    Wang, Fengwu
    Journal of Applied Polymer Science, 2009, 113 (05): : 2881 - 2886