Determination of impurities in uranium matrices by time-of-flight ICP-MS using matrix-matched method

被引:33
|
作者
Burger, S. [1 ]
Riciputi, L. R. [1 ]
Bostick, D. A. [1 ]
机构
[1] Oak Ridge Natl Lab, Transuranium Res Inst, Chem & Isotope Mass Spect Grp, Div Chem Sci, Oak Ridge, TN 37831 USA
关键词
D O I
10.1007/s10967-006-6930-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The analysis of impurities in uranium matrices is performed in a variety of fields, e.g., for quality control in the production stream converting uranium ores to fuels, as element signatures in nuclear forensics and safeguards, and for non-proliferation control. We have investigated the capabilities of time-of-flight ICP-MS for the analysis of impurities in uranium matrices using a matrix-matched method. The method was applied to the New Brunswick Laboratory CRM 124(1-7) series. For the seven certified reference materials, an overall precision and accuracy of approximately 5% and 14%, respectively, were obtained for 18 analyzed elements.
引用
收藏
页码:491 / 505
页数:15
相关论文
共 50 条
  • [21] Bromination-separation of Matrix and Determination of Sixteen Impurities in High Purity Tin by ICP-MS
    Wei Jian-Jun
    Lang Chun-Yan
    Lin Long-Fei
    Zheng Lin
    Li Jia-Xuan
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2013, 41 (06) : 927 - 930
  • [22] A beginner's guide to ICP-MS - Part VIII - Mass analyzers: Time-of-flight technology
    Thomas, R
    SPECTROSCOPY, 2002, 17 (01) : 36 - +
  • [23] The Determination of Toxic, Essential, and Nutritional Elements in Food Matrices Using an ICP-MS
    Bosnak, Cynthia
    Pruszkowski, Ewa
    AMERICAN LABORATORY, 2011, 43 (06) : 11 - 14
  • [24] Determination of trace element contaminants in food matrices using a robust, routine analytical method for ICP-MS
    Zbinden, P
    Andrey, D
    ATOMIC SPECTROSCOPY, 1998, 19 (06) : 214 - 219
  • [25] Solid phase separation and ICP-OES/ICP-MS determination of rare earth impurities in nuclear grade uranium oxide
    Durani, Smeer
    Krishnakumar, M.
    Satyanarayana, K.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2012, 294 (02) : 215 - 220
  • [26] Solid phase separation and ICP-OES/ICP-MS determination of rare earth impurities in nuclear grade uranium oxide
    Smeer Durani
    M. Krishnakumar
    K. Satyanarayana
    Journal of Radioanalytical and Nuclear Chemistry, 2012, 294 : 215 - 220
  • [27] Determination of trace impurities in tantalum pentoxide by ICP-AES and ICP-MS after trace-matrix-separation
    Opitz, M
    Wunsch, G
    JOURNAL FUR PRAKTISCHE CHEMIE-CHEMIKER-ZEITUNG, 1997, 339 (01): : 44 - 54
  • [28] Determination of Trace Impurities in Germanium Dioxide by ICP-OES, ICP-MS and ETAAS after Matrix Volatilization: A Long-run Performance of the Method
    Niemela, Matti
    Kola, Harri
    Peramaki, Paavo
    ANALYTICAL SCIENCES, 2014, 30 (07) : 735 - 738
  • [29] Determination of Trace Impurities in Germanium Dioxide by ICP-OES, ICP-MS and ETAAS after Matrix Volatilization: A Long-run Performance of the Method
    Matti Niemelä
    Harri Kola
    Paavo Perämäki
    Analytical Sciences, 2014, 30 : 735 - 738
  • [30] Rapid Sintering Method for Preparing Matrix-Matched Reference Materials in LA-MC-ICP-MS - An Example of Hafnium
    Lv, Nan
    Bao, Zhian
    Chen, Kaiyun
    Nie, Xiaojuan
    Zhang, Yan
    Peng, Deyi
    Yuan, Honglin
    ANALYTICAL CHEMISTRY, 2024,