Capillary Action-Supported Contact less Atmospheric Pressure Ionization for the Combined Sampling and Mass Spectrometric Analysis of Biomolecules

被引:37
|
作者
Hsieh, Cheng-Huan [1 ]
Chang, Chia-Hsien [1 ]
Urban, Pawel L. [1 ]
Chen, Yu-Chie [1 ]
机构
[1] Natl Chiao Tung Univ, Inst Appl Chem, Hsinchu 30050, Taiwan
关键词
EXTRACTIVE ELECTROSPRAY-IONIZATION; INTERFACE; ELECTROPHORESIS; SHEATHLESS; IONS;
D O I
10.1021/ac200479s
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
It is proposed that a short tapered capillary can be utilized as a nanoliter-volume sampling tool and sample emitter for generation of gas-phase ions in front of the mass spectrometer, without the need for using an additional electric power supply, a gas supply, or a syringe pump. A wide range of molecules can be analyzed in pure solutions and complex matrixes (cell extract, urine, and plant tissue) with no or minimum sample preparation. Singly and multiply charged ions can be detected in either positive or negative-ion mode. Because of the nanoliter-volume sampling and low spectral background, the mass detection limit for bradykinin is in the low attomole range. Other advantages include simplicity, disposability, and low cost. The putative mechanism of the ion formation in this capillary-action supported contactless spray emitter is discussed.
引用
收藏
页码:2866 / 2869
页数:4
相关论文
共 50 条
  • [41] Chaos Entropy Index Combined with Desorption Atmospheric Pressure Chemical Ionization Mass Spectrometry for Rapid Analysis of Complex Viscous Sample, Edible Oil
    Zhang, Wenjun
    Chen, Lin
    Wang, Xin
    Fang, Xiaowei
    Zhu, Zhiqiang
    Ouyang, Yongzhong
    BULLETIN OF THE CHEMICAL SOCIETY OF JAPAN, 2014, 87 (05) : 617 - 622
  • [42] ANALYSIS OF THREE AMINONITROPYRENE ISOMERS VIA FUSED SILICA GAS CHROMATOGRAPHY COMBINED WITH NEGATIVE ION ATMOSPHERIC PRESSURE IONIZATION MASS SPECTROMETRY.
    Korfmacher, W.A.
    Rushing, L.G.
    Engelbach, R.J.
    Freeman, J.P.
    Djuric, Z.
    Fifer, E.K.
    Beland, F.A.
    HRC & CC. Journal of high resolution chromatography & chromatography communications, 1987, 10 (01) : 43 - 45
  • [43] Pressure-Assisted Capillary Electrophoresis Coupling with Matrix-Assisted Laser Desorption/Ionization-Mass Spectrometric Imaging for Quantitative Analysis of Complex Peptide Mixtures
    Zhang, Zichuan
    Ye, Hui
    Wang, Junhua
    Hui, Limei
    Li, Lingjun
    ANALYTICAL CHEMISTRY, 2012, 84 (18) : 7684 - 7691
  • [44] COMBINED CAPILLARY GAS CHROMATOGRAPHY ATMOSPHERIC PRESSURE NEGATIVE CHEMICAL IONIZATION-MASS SPECTROMETRY FOR THE DETERMINATION OF 2,3,7,8-TETRACHLORODIBENZO-PARA-DIOXIN IN TISSUE
    MITCHUM, RK
    MOLER, GF
    KORFMACHER, WA
    ANALYTICAL CHEMISTRY, 1980, 52 (14) : 2278 - 2282
  • [45] Quantitative analysis of hydrocortisone in human urine using a high-performance liquid chromatographic-tandem mass spectrometric-atmospheric-pressure chemical ionization method
    Nassar, AEF
    Varshney, N
    Getek, T
    Cheng, L
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2001, 39 (02) : 59 - 64
  • [46] Temperature-programmed capillary high-performance liquid chromatography with atmospheric pressure chemical ionization mass spectrometry for analysis of fatty acid methyl esters
    Vrkoslav, Vladimir
    Rumlova, Barbora
    Strmen, Timotej
    Cvacka, Josef
    JOURNAL OF SEPARATION SCIENCE, 2020, 43 (13) : 2579 - 2588
  • [47] Gas chromatography combined with flame-induced atmospheric pressure chemical ionization mass spectrometry for the analysis of fatty acid methyl esters and saturated hydrocarbons
    Cheng, Sy-Chyi
    Lin, Hsing-Jung
    Lee, Chi-Yang
    Huang, Min-Zong
    Shiea, Jentaie
    ANALYTICA CHIMICA ACTA, 2022, 1200
  • [48] APPLICATION OF FUSED-SILICA GAS-CHROMATOGRAPHY COMBINED WITH ATMOSPHERIC-PRESSURE IONIZATION MASS-SPECTROMETRY FOR THE ANALYSIS OF AMINONITROPYRENES AND METHYLATED AMINONITROPYRENES
    KORFMACHER, WA
    RUSHING, LG
    ENGELBACH, RJ
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1987, 194 : 110 - ANYL
  • [49] Comparison of various liquid chromatographic methods involving UV and atmospheric pressure chemical ionization mass spectrometric detection for the efficient trace analysis of phenylurea herbicides in various types of water samples
    van der Heeft, E
    Dijkman, E
    Baumann, RA
    Hogendoorn, EA
    JOURNAL OF CHROMATOGRAPHY A, 2000, 879 (01) : 39 - 50
  • [50] Rapid target analysis of microcontaminants in water by on-line single-short-column liquid chromatography combined with atmospheric pressure chemical ionization tandem mass spectrometry
    Hogenboom, AC
    Speksnijder, P
    Vreeken, RJ
    Niessen, WMA
    Brinkman, UAT
    JOURNAL OF CHROMATOGRAPHY A, 1997, 777 (01) : 81 - 90