Control of biofouling in hydropower cooling systems using HOD ultraviolet light

被引:8
|
作者
Pucherelli, Sherri F. [1 ]
Claudi, Renata [2 ]
Prescott, Tom [2 ]
机构
[1] Bur Reclamat, POB 25007, Denver, CO 80225 USA
[2] RNT Consulting INC, 823 Cty Rd 35,RR 2, Picton, ON KOK 2T0, Canada
来源
MANAGEMENT OF BIOLOGICAL INVASIONS | 2018年 / 9卷 / 04期
关键词
invasive mussels; colonial hydroid; HOD UV treatment; settlement reduction; quagga mussel; dreissenid mussel control; biofouling control;
D O I
10.3391/mbi.2018.9.4.08
中图分类号
X176 [生物多样性保护];
学科分类号
090705 ;
摘要
Reservoirs along the lower Colorado River are infested with Dreissena rostriformis bugensis (Andrusov, 1897) (quagga mussel) and Cordylophora caspia (Pallas, 1771) (colonial hydroid). These invasive species, along with native freshwater sponges and bacteria, pose significant biofouling issues for hydropower facilities in the area. Biofouling in the generator cooler systems at Parker Dam, on Lake Havasu, AZ has resulted in increased annual maintenance costs of approximately $ 80,000/year. Medium pressure, hydro-optic ultraviolet (HOD UV) light systems with a 100 mJ/cm(2) target dose were installed on four main turbine cooling water lines and a raw water supply for the onsite water treatment facility at Parker Dam to mitigate biofouling. This study was designed to monitor the impact of HOD UV on biofouling over a two-year period. Comparison of biofouling dry weight from settlement plates exposed to HOD UV-treated and untreated water indicate a significant reduction in total biofouling after HOD UV exposure. Mussel settlement and bacterial sludge formation were consistently reduced in test chambers (bioboxes) despite lower than expected average HOD UV dose and contamination with untreated water. Hydroid larvae were not found in any plankton samples collected from the forebay at Parker Dam during the study, indicating asexual reproduction was the main source of downstream colony formation. Hydroid settlement reduction data after HOD UV treatment were inconclusive. The Parker Dam facility manager confirmed that biofouling-related maintenance of the coolers was reduced by 75 percent after the first year of HOD UV operation and eliminated in the second and third years after implementation.
引用
收藏
页码:451 / 461
页数:11
相关论文
共 50 条
  • [31] Biofouling control using microparticles carrying a biocide
    Ferreira, C.
    Rosmaninho, R.
    Simoes, M.
    Pereira, M. C.
    Bastos, M. M. S. M.
    Nunes, O. C.
    Coelho, M.
    Melo, L. F.
    BIOFOULING, 2010, 26 (02) : 205 - 212
  • [32] Performance assessment of oxidants as a biocide for biofouling control in industrial seawater cooling towers
    Al-Bloushi, Mohammed
    Saththasivam, Jayaprakash
    Al-Sayeghc, Sari
    Jeong, Sanghyun
    Ng, Kim Choon
    Amy, Gary L.
    Leiknes, TorOve
    JOURNAL OF INDUSTRIAL AND ENGINEERING CHEMISTRY, 2018, 59 : 127 - 133
  • [33] Biofouling Management in the Cooling Circuit of a Power Industry Using Electrochemical Process
    Saleem, Muhammad
    JOURNAL OF THE CHEMICAL SOCIETY OF PAKISTAN, 2011, 33 (03): : 295 - 304
  • [34] Building Indoor Temperature Control Using Model Predictive Control in Cooling Systems
    Boo, Chang-Jin
    Kim, Jeong-Hyuk
    Kim, Ho-Chan
    Lee, Kwang Y.
    IFAC PAPERSONLINE, 2015, 48 (30): : 316 - 320
  • [35] Non-chemical biofouling mitigation systems for seawater cooling tower using granular activated carbon biofiltration and ultrafiltration
    Mohammed, Al-Bloushi
    Raju, Arun Kumar S.
    Lee, Jieun
    Oh, Yumin
    Jeong, Sanghyun
    JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2021, 9 (06):
  • [36] Selective bond breakage within the HOD molecule using optimized femtosecond ultraviolet laser pulses
    Tiwari, Ashwani Kumar
    Moller, Klaus B.
    Henriksen, Niels E.
    PHYSICAL REVIEW A, 2008, 78 (06):
  • [37] CONTROL OF INDUSTRIAL COOLING SYSTEMS
    PUGH, W
    CME-CHARTERED MECHANICAL ENGINEER, 1978, 25 (02): : 71 - 74
  • [38] PRACTICAL ASPECTS OF BIOFOULING CONTROL IN INDUSTRIAL WATER-SYSTEMS
    CLOETE, TE
    BROZEL, VS
    VONHOLY, A
    INTERNATIONAL BIODETERIORATION & BIODEGRADATION, 1992, 29 (3-4) : 299 - 341
  • [39] Efficacy of ultraviolet light systems for control of microorganisms in poultry and beef brine and marinade solutions
    Beers, K. L.
    Cook, P. E.
    Coleman, C. W.
    Waldroup, A. L.
    JOURNAL OF DAIRY SCIENCE, 2010, 93 : 615 - 615
  • [40] Pulsed acoustics for biofouling control in heat exchangers and piping systems
    Brizzolara, RA
    Walch, M
    Nordham, DJ
    Hoover, SM
    Mazzola, MS
    Burnett, E
    Licina, GJ
    PROCEEDINGS OF AN INTERNATIONAL CONFERENCE ON MITIGATION OF HEAT EXCHANGER FOULING AND ITS ECONOMIC AND ENVIRONMENTAL IMPLICATIONS, 2001, : 153 - 160