Extensive frontal focused ultrasound mediated blood-brain barrier opening for the treatment of Alzheimer's disease: a proof-of-concept study

被引:58
|
作者
Park, So Hee [1 ]
Baik, Kyoungwon [2 ]
Jeon, Seun [2 ]
Chang, Won Seok [1 ]
Ye, Byoung Seok [2 ]
Chang, Jin Woo [1 ]
机构
[1] Yonsei Univ, Brain Res Inst, Dept Neurosurg, Coll Med, Seoul, South Korea
[2] Yonsei Univ, Dept Neurol, Coll Med, Seoul, South Korea
基金
新加坡国家研究基金会;
关键词
Alzheimer disease; Focused ultrasound; Blood-brain barrier; Amyloid beta-peptides; PLAQUE REDUCTION; BETA PLAQUES;
D O I
10.1186/s40035-021-00269-8
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Background: Focused ultrasound (FUS)-mediated blood-brain barrier (BBB) opening has shown efficacy in removal of amyloid plaque and improvement of cognitive functions in preclinical studies, but this is rarely reported in clinical studies. This study was conducted to evaluate the safety, feasibility and potential benefits of repeated extensive BBB opening. Methods: In this open-label, prospective study, six patients with Alzheimer's disease (AD) were enrolled at Severance Hospital in Korea between August 2020 and September 2020. Five of them completed the study. FUS-mediated BBB opening, targeting the bilateral frontal lobe regions over 20 cm(3), was performed twice at three-month intervals. Magnetic resonance imaging, F-18-Florbetaben (FBB) positron emission tomography, Caregiver-Administered Neuropsychiatric Inventory (CGA-NPI) and comprehensive neuropsychological tests were performed before and after the procedures. Results: FUS targeted a mean volume of 21.1 +/- 2.7 cm(3) and BBB opening was confirmed at 95.7%+/- 9.4% of the targeted volume. The frontal-to-other cortical region FBB standardized uptake value ratio at 3 months after the procedure showed a slight decrease, which was statistically significant, compared to the pre-procedure value (- 1.6%, 0.986 vs1.002, P= 0.043). The CGA-NPI score at 2 weeks after the second procedure significantly decreased compared to baseline (2.2 +/- 3.0 vs 8.6 +/- 6.0, P = 0.042), but recovered after 3 months (5.2 +/- 5.8 vs 8.6 +/- 6.0, P = 0.89). No adverse effects were observed. Conclusions: The repeated and extensive BBB opening in the frontal lobe is safe and feasible for patients with AD. In addition, the BBB opening is potentially beneficial for amyloid removal in AD patients.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Ultrasound-mediated blood-brain barrier opening uncovers an intracerebral perivenous fluid network in persons with Alzheimer's disease
    Mehta, Rashi I.
    Carpenter, Jeffrey S.
    Mehta, Rupal I.
    Haut, Marc W.
    Wang, Peng
    Ranjan, Manish
    Najib, Umer
    D'Haese, Pierre-Francois
    Rezai, Ali R.
    FLUIDS AND BARRIERS OF THE CNS, 2023, 20 (01)
  • [32] Focused-Ultrasound Mediated Blood-Brain Barrier Disruption
    McDannold, N.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [33] Noninvasive and Transient Blood-Brain Barrier Opening in the Hippocampus of Alzheimer's Double Transgenic Mice Using Focused Ultrasound
    Choi, James J.
    Wang, Shougang
    Brown, Truman R.
    Small, Scott A.
    Duff, Karen E. K.
    Konofagou, Elisa E.
    ULTRASONIC IMAGING, 2008, 30 (03) : 189 - 200
  • [34] Safety, Efficacy and Clinical Applications of Focused Ultrasound-Mediated Blood Brain Barrier Opening in Alzheimer's Disease: A Systematic Review
    Patwardhan, A.
    Wilkinson, T.
    Meng, Y.
    Alhashyan, I.
    Black, S. E.
    Lipsman, N.
    Masellis, M.
    JPAD-JOURNAL OF PREVENTION OF ALZHEIMERS DISEASE, 2024, 11 (04): : 975 - 982
  • [35] Recent Advances on Ultrasound Contrast Agents for Blood-Brain Barrier Opening with Focused Ultrasound
    Dauba, Ambre
    Delalande, Anthony
    Kamimura, Hermes A. S.
    Conti, Allegra
    Larrat, Benoit
    Tsapis, Nicolas
    Novell, Anthony
    PHARMACEUTICS, 2020, 12 (11) : 1 - 30
  • [36] The blood-brain barrier in Alzheimer's disease
    Zenaro, Elena
    Piacentino, Gennj
    Constantin, Gabriela
    NEUROBIOLOGY OF DISEASE, 2017, 107 : 41 - 56
  • [37] Opening the Blood-Brain Barrier in the Substantia Nigra of Rat Brain with Focused Ultrasound and Microbubbles
    Rodriguez, J. A.
    Reyes, C. J.
    Gutierrez, M., I
    Vera, A.
    Martinez-Fong, D.
    Negreira, C.
    Leija, L.
    2019 GLOBAL MEDICAL ENGINEERING PHYSICS EXCHANGES/PAN AMERICAN HEALTH CARE EXCHANGES (GMEPE/PAHCE), 2019,
  • [38] Preclinical Research on Focused Ultrasound-Mediated Blood-Brain Barrier Opening for Neurological Disorders: A Review
    Kong, Chanho
    Chang, Won Seok
    NEUROLOGY INTERNATIONAL, 2023, 15 (01): : 285 - 300
  • [39] Focused ultrasound mediated blood-brain barrier opening is safe and feasible in a murine pontine glioma model
    Englander, Zachary K.
    Wei, Hong-Jian
    Pouliopoulos, Antonios N.
    Bendau, Ethan
    Upadhyayula, Pavan
    Jan, Chia-Ing
    Spinazzi, Eleanora F.
    Yoh, Nina
    Tazhibi, Masih
    McQuillan, Nicholas M.
    Wang, Tony J. C.
    Bruce, Jeffrey N.
    Canoll, Peter
    Feldstein, Neil A.
    Zacharoulis, Stergios
    Konofagou, Elisa E.
    Wu, Cheng-Chia
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [40] Targeting diffuse midline gliomas: The promise of focused ultrasound-mediated blood-brain barrier opening
    Martinez, Payton J.
    Green, Adam L.
    Borden, Mark A.
    JOURNAL OF CONTROLLED RELEASE, 2024, 365 : 412 - 421