Measurement of Myocardial Extracellular Volume Fraction FromIodine Density Images Using Single-Source, Dual-Energy Computed Tomography: A Feasibility Study

被引:21
|
作者
Ohta, Yasutoshi [1 ]
Kitao, Shinichiro [1 ]
Watanabe, Tomomi [2 ]
Mukai, Natsuko [2 ]
Kishimoto, Junichi [3 ]
Yamamoto, Kazuhiro [2 ]
Ogawa, Toshihide [1 ]
机构
[1] Tottori Univ, Fac Med, Div Radiol, Dept Pathophysiol Therapeut Sci, Yonago, Tottori, Japan
[2] Tottori Univ, Fac Med, Div Mol Med & Therapeut, Dept Multidisciplinary Internal Med, Yonago, Tottori, Japan
[3] Tottori Univ Hosp, Dept Clin Radiol, Yonago, Tottori, Japan
关键词
dual-energy computed tomography; extracellular volume fraction; gemstone spectral imaging; myocardium; spectral imaging; CARDIOVASCULAR MAGNETIC-RESONANCE; DOSE CARDIAC CT; HEART-FAILURE; FIBROSIS; QUANTIFICATION; ASSOCIATION; AMYLOIDOSIS; VALIDATION; EXPERIENCE; HEALTH;
D O I
10.1097/RCT.0000000000000587
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: The aims of this study were to develop and validate an iodine density method for the quantification of myocardial extracellular volume (ECV) fraction using single-source, dual-energy computed tomography. Methods: Extracellular volume measurements were carried out in 40 subjects (20 patients with heart failure, 20 control subjects) using single-source, dual-energy computed tomography. Subtraction-derived ECVs (subECVs) were computed by subtracting precontrast from delayed images. Iodine density-derived ECVs (iECVs) were calculated from iodine density images obtained from delayed images. Iodine density-derived ECVs were compared with reference subECVs. Results: A strong correlation (r = 0.896, P < 0.0001) and a small bias (-0.06%) were determined between subECVand iECV with high interobserver concordances (0.915 and 0.906, respectively). Extracellular volume measurements in patients with heart failure were higher in both subECV and iECV compared with control subjects (34.6% [SD, 5.0%] vs 29.5% [SD, 3.6%], P = 0.001, for subECV; 34.9% [SD, 4.5%] vs 29.2% [SD, 2.6%], P < 0.0001, for iECV). Conclusions: Extracellular volume analysis using iodine density is a useful tool for the noninvasive quantification of ECV in myocardial diseases.
引用
收藏
页码:750 / 756
页数:7
相关论文
共 50 条
  • [31] Prognostic Impact of Myocardial Extracellular Volume Fraction Assessment Using Dual-Energy Computed Tomography in Patients Treated With Aortic Valve Replacement for Severe Aortic Stenosis
    Suzuki, Masataka
    Toba, Takayoshi
    Izawa, Yu
    Fujita, Hiroshi
    Miwa, Keisuke
    Takahashi, Yu
    Toh, Hiroyuki
    Kawamori, Hiroyuki
    Otake, Hiromasa
    Tanaka, Hidekazu
    Fujiwara, Sei
    Watanabe, Yoshiaki
    Kono, Atsushi K.
    Okada, Kenji
    Hirata, Ken-Ichi
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2021, 10 (18):
  • [32] Quantitative and Qualitative Comparison of Single-Source Dual-Energy Computed Tomography and 120-kVp Computed Tomography for the Assessment of Pancreatic Ductal Adenocarcinoma
    Bhosale, Priya
    Le, Ott
    Balachandran, Aprana
    Fox, Patricia
    Paulson, Eric
    Tamm, Eric
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2015, 39 (06) : 907 - 913
  • [33] Dual-Energy Computed Tomography Angiography of the Head and Neck With Single-Source Computed Tomography: A New Technical (Split Filter) Approach for Bone Removal
    Kaemmerer, Nadine
    Brand, Michael
    Hammon, Matthias
    May, Matthias
    Wuest, Wolfgang
    Krauss, Bernhard
    Uder, Michael
    Lell, Michael M.
    INVESTIGATIVE RADIOLOGY, 2016, 51 (10) : 618 - 623
  • [34] Myocardial Extracellular Volume Quantification Using Cardiac Computed Tomography: A Comparison of the Dual-energy Iodine Method and the Standard Subtraction Method
    Emoto, Takafumi
    Oda, Seitaro
    Kidoh, Masafumi
    Nakaura, Takeshi
    Nagayama, Yasunori
    Sakabe, Daisuke
    Kakei, Kiyotaka
    Goto, Makoto
    Funama, Yoshinori
    Hatemura, Masahiro
    Takashio, Seiji
    Kaikita, Koichi
    Tsujita, Kenichi
    Ikeda, Osamu
    ACADEMIC RADIOLOGY, 2021, 28 (05) : E119 - E126
  • [35] Myocardial iodine concentration measurement using dual-energy computed tomography for the diagnosis of cardiac amyloidosis: a pilot study
    Chevance, Virgile
    Damy, Thibaud
    Tacher, Vania
    Legou, Francois
    Ridouani, Fourat
    Luciani, Alain
    Kobeiter, Hicham
    Rahmouni, Alain
    Deux, Jean-Francois
    EUROPEAN RADIOLOGY, 2018, 28 (02) : 816 - 823
  • [36] Myocardial iodine concentration measurement using dual-energy computed tomography for the diagnosis of cardiac amyloidosis: a pilot study
    Virgile Chevance
    Thibaud Damy
    Vania Tacher
    François Legou
    Fourat Ridouani
    Alain Luciani
    Hicham Kobeiter
    Alain Rahmouni
    Jean-François Deux
    European Radiology, 2018, 28 : 816 - 823
  • [37] An algorithm for noise correction of dual-energy computed tomography material density images
    Rafael Simon Maia
    Christian Jacob
    Amy K. Hara
    Alvin C. Silva
    William Pavlicek
    Mitchell J. Ross
    International Journal of Computer Assisted Radiology and Surgery, 2015, 10 : 87 - 100
  • [38] An algorithm for noise correction of dual-energy computed tomography material density images
    Maia, Rafael Simon
    Jacob, Christian
    Hara, Amy K.
    Silva, Alvin C.
    Pavlicek, William
    Ross, Mitchell J.
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2015, 10 (01) : 87 - 100
  • [39] Single-source dual energy CT to assess myocardial extracellular volume fraction in aortic stenosis before transcatheter aortic valve implantation (TAVI)
    Dubourg, Benjamin
    Dacher, Jean-Nicolas
    Durand, Eric
    Caudron, Jerome
    Bauer, Fabrice
    Bubenheim, Michael
    Eltchaninoff, Helene
    Serfaty, Jean-Michel
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2021, 102 (09) : 561 - 570
  • [40] A feasibility study of using virtual noncontrast images synthesized from dual-energy computed tomography for radiotherapy treatment planning
    Wei, Shuoyang
    Zhu, Qizhen
    Yu, Lang
    Li, Wenbo
    Zhou, Bing
    Guo, Mengya
    Dai, Jiaqi
    Liu, Xiaonan
    Yang, Bo
    Qiu, Jie
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2024, 14 (12) : 8443 - 8455