Experimental investigation of evaporative heat transfer characteristics at the 3-phase contact line

被引:45
|
作者
Ibrahem, K. [1 ,2 ,3 ]
Abd Rabbo, M. F. [3 ]
Gambaryan-Roisman, T. [1 ,2 ]
Stephan, P. [1 ,2 ]
机构
[1] Tech Univ Darmstadt, Inst Tech Thermodynam, D-64287 Darmstadt, Germany
[2] Tech Univ Darmstadt, Ctr Smart Interfaces, D-64287 Darmstadt, Germany
[3] Benha Univ, Shoubra Fac Engn, Dept Mech Engn, Cairo, Egypt
关键词
3-Phase contact line; Meniscus; Micro-region; Heat transfer; LOW GRAVITY CONDITIONS; ETHANOL MENISCUS; VAPOR BUBBLE; EXCHANGER;
D O I
10.1016/j.expthermflusci.2010.02.014
中图分类号
O414.1 [热力学];
学科分类号
摘要
An experimental study is conducted to investigate the local heat flow at a solid-liquid-vapor contact line. A vertical channel of 600 mu m width is built using two parallel flat plates; a 10 mu m thick stainless steel heating foil forms a part of one of the flat plates. A liquid-vapor meniscus is formed between the plates due to capillary forces. In this study the fluid HFE7100 is evaporated inside the channel under steady state conditions. Two-dimensional microscale temperature fields at the back side of the heating foil are observed with a infrared camera with a spatial resolution of 14.8 mu m x 14.8 mu m. An in situ calibration procedure is applied. The measured local wall temperature difference between the contact line area and the bulk liquid is up to 12 K. The liquid front undergoes a slow oscillatory motion which can be attributed to the instability of evaporating 3-phase contact line. The local heat fluxes from the heater to the evaporating meniscus are calculated from the measured wall temperatures using an energy balance for each pixel element. The local heat fluxes at the contact line area are found to be about 5.4-6.5 times higher than the mean input heat fluxes at the foil. (C) 2010 Elsevier Inc. All rights reserved.
引用
收藏
页码:1036 / 1041
页数:6
相关论文
共 50 条
  • [21] 3-PHASE CONTACT LINE MOTION IN THE DEPOSITION OF SPREAD MONOLAYERS
    PETROV, JG
    KUHN, H
    MOBIUS, D
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 1980, 73 (01) : 66 - 75
  • [22] 3-PHASE CONTACT LINE MOTION IN DEPOSITION OF SPREAD MONOLAYERS
    PETROV, JG
    KUHN, H
    MOBIUS, D
    BERICHTE DER BUNSEN-GESELLSCHAFT-PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 1978, 82 (09): : 884 - 884
  • [23] CONTACT-ANGLE HYSTERESIS AND THE SHAPE OF THE 3-PHASE LINE
    SCHWARTZ, LW
    GAROFF, S
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 1985, 106 (02) : 422 - 437
  • [24] Experimental Investigation of the Operation Characteristics of 3-Phase 3-Wire Active Power Filter
    Han, Yang
    Song, Wen-Xiang
    Xu, Lin
    Yao, Gang
    Zhou, Li-Dan
    Khan, M. M.
    Chen, Chen
    2008 IEEE ASIA PACIFIC CONFERENCE ON CIRCUITS AND SYSTEMS (APCCAS 2008), VOLS 1-4, 2008, : 97 - 100
  • [25] HEAT-TRANSFER CHARACTERISTICS IN 2-PHASE AND 3-PHASE SLURRY-FLUIDIZED BEDS
    KIM, SD
    KANG, Y
    KWON, HK
    AICHE JOURNAL, 1986, 32 (08) : 1397 - 1400
  • [26] A Dimensionless Number for the Contact Line Evaporative Heat Sink
    Wayner, P. C., Jr.
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1989, 111 (1-4): : 813 - 815
  • [27] Experimental analysis of heat and mass transfer phenomena in a direct contact evaporative cooling tower
    Lemouari, M.
    Boumaza, M.
    Kaabi, A.
    ENERGY CONVERSION AND MANAGEMENT, 2009, 50 (06) : 1610 - 1617
  • [28] HEAT-TRANSFER IN 3-PHASE FLUIDIZED-BEDS
    BAKER, CGJ
    ARMSTRONG, ER
    BERGOUGNOU, MA
    POWDER TECHNOLOGY, 1978, 21 (02) : 195 - 204
  • [29] HEAT-TRANSFER IN 3-PHASE FLUIDIZED-BEDS
    CHIU, TM
    ZIEGLER, EN
    AICHE JOURNAL, 1983, 29 (04) : 677 - 685
  • [30] Experimental Investigation of Heat Transfer in Plate Modules of a Heat and Mass Transfer Contact Device
    Stepykin, A., V
    Kosyrev, V. M.
    Sidyagin, A. A.
    Bukharov, D. M.
    Tutanina, E. M.
    CHEMICAL AND PETROLEUM ENGINEERING, 2022, 58 (1-2) : 96 - 103