Ambulatory 24-hour double-probe pH monitoring: The importance of manometry

被引:24
|
作者
Johnson, PE [1 ]
Koufman, JA [1 ]
Nowak, LJ [1 ]
Belafsky, PC [1 ]
Postma, GN [1 ]
机构
[1] Wake Forest Univ, Bowman Gray Sch Med, Dept Otolaryngol, Ctr Voice Disorders, Winston Salem, NC 27157 USA
来源
LARYNGOSCOPE | 2001年 / 111卷 / 11期
关键词
manometry; pH monitoring; extraesophageal reflux; pH probes; GERD; reflux; laryngopharyngeal reflux;
D O I
10.1097/00005537-200111000-00019
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objective: Historically, manometry has been used for sphincter localization before ambulatory 24-hour double-probe pH monitoring to ensure accurate placement of the probes. Recently, direct-vision placement (DVP), using transnasal fiberoptic laryngoscopy (TFL), has been offered as an alternative technique. Presumably, DVP might be used to precisely place the proximal (pharyngeal) pH probe; however, using DVP, there appears to be no way to accurately position the distal (esophageal) probe. The purpose of this study was to evaluate the accuracy of DVP for pH probe placement using manometric measurement as the gold standard. Methods: Thirty patients undergoing pH monitoring participated in this prospective study. Each subject underwent manometric examination of the esophagus to determine the precise location of the upper and lower esophageal sphincters (LES and LES). In addition, external anatomic landmarks were used to estimate interprobe distances. A physician blinded to the manometry results then placed a pH catheter using DVP so that the proximal probe was located just above the UES. The results were recorded and compared with those obtained by manometry. Results: Accurate DVP of the proximal pH probe was achieved in 70% (23 of 30) of the subjects. The use of external anatomic landmarks to estimate interprobe distance resulted in accurate positioning of the distal probe in only 40% (12 of 30) of the subjects. Using fixed interprobe distances of 15 cm and 20 cm, distal probe position accuracy was 3% (I of 30) and 40% (12 of 30), respectively. Therefore, using DV-P, the distal esophageal probe was in an incorrect position in 60% to 97% of subjects. Conclusion: For double-probe pH monitoring, the proximal probe can be accurately positioned by DVP; however, there is no precise way to determine the interprobe distance required to correctly position the distal pH probe. Failure to accurately position the distal probe results in grossly inaccurate esophageal acid-exposure times. Thus, manometry is needed to ensure valid double-probe pH monitoring data.
引用
收藏
页码:1970 / 1975
页数:6
相关论文
共 50 条
  • [31] 24-HOUR INTRAESOPHAGEAL PH MONITORING
    GALMICHE, JP
    LEHUR, PA
    DESVARANNES, SB
    DENIS, P
    GASTROENTEROLOGY, 1986, 91 (06) : 1581 - 1582
  • [32] 24-hour pH monitoring of the hypopharynx
    Schlottmann, A
    Wilke, W
    Pahn, J
    HNO, 1999, 47 (02) : 112 - 116
  • [33] 24-HOUR GASTRIC PH MONITORING
    BARLOW, AP
    PROBLEMS IN GENERAL SURGERY, 1992, 9 (01): : 124 - 137
  • [34] 24-HOUR AMBULATORY ELECTROENCEPHALOGRAPHIC MONITORING IN PEDIATRICS
    BACHMAN, DS
    ANNALS OF NEUROLOGY, 1982, 12 (02) : 207 - 207
  • [35] Selective use of esophageal manometry and 24-hour pH monitoring before laparoscopic fundoplication
    Frantzides, CT
    Carlson, MA
    Madan, AK
    Stewart, ET
    Smith, C
    JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2003, 197 (03) : 358 - 363
  • [36] 24-hour ambulatory blood pressure monitoring
    Anlauf, M
    Baumgart, P
    Franz, IW
    Krönig, B
    Middeke, M
    Schrader, J
    Schulte, KL
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1998, 123 (47) : 1426 - 1430
  • [37] Ambulatory 24-hour esophageal pH monitoring - Why, when, and what to do
    Streets, CG
    DeMeester, TR
    JOURNAL OF CLINICAL GASTROENTEROLOGY, 2003, 37 (01) : 14 - 22
  • [38] 24-HOUR AMBULATORY MOTILITY AND PH MONITORING FOR EVALUATION OF NONCARDIAC CHEST PAIN
    DEPREZ, P
    FIASSE, R
    GASTROENTEROLOGY, 1993, 104 (04) : A70 - A70
  • [39] 24-HOUR AMBULATORY ESOPHAGEAL PH MONITORING IN UNCOMPLICATED BARRETTS-ESOPHAGUS
    NEUMANN, CS
    HERON, RJL
    COOPER, BT
    GUT, 1991, 32 (10) : A1211 - A1211
  • [40] CLINICAL-APPLICATION OF 24-HOUR AMBULATORY ESOPHAGEAL PH AND PRESSURE MONITORING
    SMOUT, AJPM
    LAM, HGT
    BREUMELHOF, R
    SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 1992, 27 : 30 - 37