Ambulatory 24-hour double-probe pH monitoring: The importance of manometry

被引:24
|
作者
Johnson, PE [1 ]
Koufman, JA [1 ]
Nowak, LJ [1 ]
Belafsky, PC [1 ]
Postma, GN [1 ]
机构
[1] Wake Forest Univ, Bowman Gray Sch Med, Dept Otolaryngol, Ctr Voice Disorders, Winston Salem, NC 27157 USA
来源
LARYNGOSCOPE | 2001年 / 111卷 / 11期
关键词
manometry; pH monitoring; extraesophageal reflux; pH probes; GERD; reflux; laryngopharyngeal reflux;
D O I
10.1097/00005537-200111000-00019
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objective: Historically, manometry has been used for sphincter localization before ambulatory 24-hour double-probe pH monitoring to ensure accurate placement of the probes. Recently, direct-vision placement (DVP), using transnasal fiberoptic laryngoscopy (TFL), has been offered as an alternative technique. Presumably, DVP might be used to precisely place the proximal (pharyngeal) pH probe; however, using DVP, there appears to be no way to accurately position the distal (esophageal) probe. The purpose of this study was to evaluate the accuracy of DVP for pH probe placement using manometric measurement as the gold standard. Methods: Thirty patients undergoing pH monitoring participated in this prospective study. Each subject underwent manometric examination of the esophagus to determine the precise location of the upper and lower esophageal sphincters (LES and LES). In addition, external anatomic landmarks were used to estimate interprobe distances. A physician blinded to the manometry results then placed a pH catheter using DVP so that the proximal probe was located just above the UES. The results were recorded and compared with those obtained by manometry. Results: Accurate DVP of the proximal pH probe was achieved in 70% (23 of 30) of the subjects. The use of external anatomic landmarks to estimate interprobe distance resulted in accurate positioning of the distal probe in only 40% (12 of 30) of the subjects. Using fixed interprobe distances of 15 cm and 20 cm, distal probe position accuracy was 3% (I of 30) and 40% (12 of 30), respectively. Therefore, using DV-P, the distal esophageal probe was in an incorrect position in 60% to 97% of subjects. Conclusion: For double-probe pH monitoring, the proximal probe can be accurately positioned by DVP; however, there is no precise way to determine the interprobe distance required to correctly position the distal pH probe. Failure to accurately position the distal probe results in grossly inaccurate esophageal acid-exposure times. Thus, manometry is needed to ensure valid double-probe pH monitoring data.
引用
收藏
页码:1970 / 1975
页数:6
相关论文
共 50 条
  • [1] Reflux in infants with laryngomalacia: Results of 24-hour double-probe pH monitoring
    Matthews, BL
    Little, JP
    McGuirt, WF
    Koufman, JA
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 1999, 120 (06) : 860 - 864
  • [2] Extraesophageal pediatric reflux: 24-hour double-probe pH monitoring of 222 children
    Little, JP
    Matthews, BL
    Glock, MS
    Koufman, JA
    Reboussin, DM
    Loughlin, CJ
    McGuirt, WF
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 1997, 106 (07): : 1 - 16
  • [3] 24-HOUR AMBULATORY ESOPHAGEAL PH MONITORING
    MCLAUCHLAN, G
    LUCAS, ML
    MCCOLL, KEL
    BRITISH JOURNAL OF SURGERY, 1987, 74 (08) : 758 - 758
  • [4] 24-HOUR AMBULATORY MONITORING OF GASTRIC PH
    KAPUR, B
    HOWLETT, PJ
    KENYON, NG
    LUNT, MJ
    MILLS, J
    SMALLWOOD, RH
    WILSON, AJ
    BARDHAN, KD
    GUT, 1983, 24 (10) : 1003 - 1003
  • [5] Gastroesophageal manometry and 24-hour double pH monitoring in neonates with birth asphyxia
    Mei Sun~1 Wei-Lin Wang~2 Wei Wang~2 De-Liang Wen~1 Hui Zhang~1 Yu-Kun Han~1 1 Pediatric Department
    World Journal of Gastroenterology, 2001, (05) : 695 - 697
  • [6] Gastroesophageal manometry and 24-hour double pH monitoring in neonates with birth asphyxia
    Sun, M
    Wang, WL
    Wang, W
    Wen, DL
    Zhang, H
    Han, YK
    WORLD JOURNAL OF GASTROENTEROLOGY, 2001, 7 (05) : 695 - 697
  • [7] Reproducibility of proximal probe pH parameters in 24-hour ambulatory esophageal pH monitoring
    Vaezi, MF
    Schroeder, PL
    Richter, JE
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 1997, 92 (05): : 825 - 829
  • [8] The comparison of an empiric proton pump inhibitor trial vs 24-hour double-probe Ph monitoring in laryngopharyngeal reflux
    Bilgen, C
    Ögüt, F
    Kesimli-Dinç, H
    Kirazli, T
    Bor, S
    JOURNAL OF LARYNGOLOGY AND OTOLOGY, 2003, 117 (05): : 386 - 390
  • [9] Manometry and 24-hour ambulatory pH monitoring at two levels of the esophagus in patients with and without esophagitis
    Mantilla, CS
    de Leon, AR
    de la Serna, JP
    Taxonera, C
    Paredes, JG
    Rubio, MD
    REVISTA ESPANOLA DE ENFERMEDADES DIGESTIVAS, 1998, 90 (03) : 150 - 154
  • [10] AMBULATORY INTRAESOPHAGEAL 24-HOUR PH-MONITORING
    JOELSSON, B
    SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 1988, 23 : 89 - 93