T2-weighted Lung Imaging Using a 0.55-T MRI System

被引:19
|
作者
Campbell-Washburn, Adrienne E. [1 ]
Malayeri, Ashkan A. [3 ]
Jones, Elizabeth C. [3 ]
Moss, Joel [2 ]
Fennelly, Kevin P. [2 ]
Olivier, Kenneth N. [2 ]
Chen, Marcus Y. [1 ]
机构
[1] NHLBI, Cardiovasc Branche, Div Intramural Res, NIH,Dept Hlth & Human Serv, Bldg 10,Room BID-47,10 Ctr Dr, Bethesda, MD 20892 USA
[2] NHLBI, Pulm Branche, Div Intramural Res, NIH,Dept Hlth & Human Serv, Bldg 10,Room BID-47,10 Ctr Dr, Bethesda, MD 20892 USA
[3] NIH, Dept Radiol & Imaging Sci, Clin Ctr, Dept Hlth & Human Serv, Bethesda, MD 20892 USA
来源
RADIOLOGY-CARDIOTHORACIC IMAGING | 2021年 / 3卷 / 03期
关键词
MRI; Pulmonary; Technology Assessment; PULMONARY NODULES; IMMUNOCOMPROMISED PATIENTS; ECHO; SEQUENCES;
D O I
10.1148/ryct.2021200611
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess a 0.55-T MRI system for imaging lung disease and to compare image quality with clinical CT scans. Materials and Methods: In this prospective study conducted between November 2018 and December 2019, respiratory-triggered T2weighted turbo spin-echo MRI at 0.55 T was compared with clinical CT scans in 24 participants (mean age, 59 years 6 16 [standard deviation]; 18 women) with common lung abnormalities. MR images were reviewed and scored by experienced readers. Abnormal findings identified with MRI and CT were compared using the Cohen k statistic. Results: High-quality structural pulmonary MR images were attained with an average acquisition time of 11 minutes 6 3. MRI generated sufficient image quality to robustly detect bronchiectasis (k = 0.61), consolidative opacities (k = 1.00), cavitary lesions (k = 1.00), effusion (k = 0.64), mucus plug (k = 0.68), and solid scattered nodularity (k = 0.82). Diffuse disease, including ground-glass opacities (k = 0.57) and tree-in-bud nodules (k = 0.48), were the findings that were most difficult to discern using MRI, with false readings in four of 18 patients for each feature. Nodule size, which was measured independently at CT and MRI, was strongly correlated (R-2 = 0.99) for nodules with a measurement of 10 mm +/- 5 (range, 5-23 mm). Conclusion: This initial study indicates that high-performance 0.55-T MRI holds promise in the evaluation of common lung disease.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Evaluation of jugular foramen nerves by using b-FFE, T2-weighted DRIVE, T2-weighted FSE and post-contrast T1-weighted MRI sequences
    Aydin, Hasan
    Altin, Elif
    Dilli, Alper
    Sipahioglu, Serdar
    Hekimoglu, Baki
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2011, 17 (01) : 3 - 9
  • [42] Is there a role for BLADE acquisition in T2-weighted breast MRI?
    Ozcan, Umit Aksoy
    Dincer, Alp
    Yildiz, M. Erdem
    Cinko, Murat
    Cizmeli, M. Olcay
    ACTA RADIOLOGICA, 2010, 51 (10) : 1078 - 1085
  • [43] An Intercenter Intensity Normalization for Prostate T2-Weighted MRI
    Gholizadeh, N.
    Greer, P.
    Lau, P.
    Ramadan, S.
    Simpson, J.
    ASIA-PACIFIC JOURNAL OF CLINICAL ONCOLOGY, 2017, 13 : 24 - 25
  • [44] Scanner-based real-time three-dimensional brain plus body slice-to-volume reconstruction for T2-weighted 0.55-T low-field fetal magnetic resonance imaging
    Uus, Alena
    Silva, Sara Neves
    Verdera, Jordina Aviles
    Payette, Kelly
    Hall, Megan
    Colford, Kathleen
    Luis, Aysha
    Sousa, Helena
    Ning, Zihan
    Roberts, Thomas
    Mcelroy, Sarah
    Deprez, Maria
    Hajnal, Joseph
    Rutherford, Mary
    Story, Lisa
    Hutter, Jana
    PEDIATRIC RADIOLOGY, 2025, 55 (03) : 556 - 569
  • [45] Performance of PROPELLER relative to standard FSE T2-weighted imaging in pediatric brain MRI
    Vertinsky, A. Talia
    Rubesova, Erika
    Krasnokutsky, Michael V.
    Bammer, Sabine
    Rosenberg, Jarrett
    White, Allan
    Barnes, Patrick D.
    Bammer, Roland
    PEDIATRIC RADIOLOGY, 2009, 39 (10) : 1038 - 1047
  • [46] 3D T2-weighted imaging to shorten multiparametric prostate MRI protocols
    Stephan H. Polanec
    Mathias Lazar
    Georg J. Wengert
    Hubert Bickel
    Claudio Spick
    Martin Susani
    Shahrokh Shariat
    Paola Clauser
    Pascal A. T. Baltzer
    European Radiology, 2018, 28 : 1634 - 1641
  • [47] Multiparametric prostate MRI: focus on T2-weighted imaging and role in staging of prostate cancer
    Gupta, Rajan T.
    Spilseth, Benjamin
    Patel, Nayana
    Brown, Alison F.
    Yu, Jinxing
    ABDOMINAL RADIOLOGY, 2016, 41 (05) : 831 - 843
  • [48] Automatic quantification of perivascular spaces in T2-weighted images at 7 T MRI
    Spijkerman, J. M.
    Zwanenburg, J. J. M.
    Bouvy, W. H.
    Geerlings, M. I.
    Biessels, G. J.
    Hendrikse, J.
    Luijten, P. R.
    Kuijf, H. J.
    CEREBRAL CIRCULATION-COGNITION AND BEHAVIOR, 2022, 3
  • [49] T2-weighted balanced SSFP imaging (T2-TIDE) using variable flip angles
    Paul, Dominik
    Markl, Michael
    Fautz, Hans-Peter
    Hennig, Juergen
    MAGNETIC RESONANCE IN MEDICINE, 2006, 56 (01) : 82 - 93
  • [50] Performance of PROPELLER relative to standard FSE T2-weighted imaging in pediatric brain MRI
    A. Talia Vertinsky
    Erika Rubesova
    Michael V. Krasnokutsky
    Sabine Bammer
    Jarrett Rosenberg
    Allan White
    Patrick D. Barnes
    Roland Bammer
    Pediatric Radiology, 2009, 39 : 1038 - 1047