This paper presents the methods and results of the processing of response only data collected from the Z24 bridge in Switzerland. Two sets of data were analysed: (1) data from drop weight forced vibration measurements, where the excitation force was not measured, and (2) data from ambient vibration measurements. it was found that the spectral estimates from the forced vibration measurements were of higher quality and therefore led to more consistent and reliable estimated modal parameters, even for this fairly crude method of forced vibration testing. It is possible that the results from ambient vibration testing could have been improved if longer data acquisition times were utilised.
引用
收藏
页码:846 / 851
页数:2
相关论文
共 50 条
  • [31] Bridge scour evaluation based on ambient vibration
    Lin, Tzu-Kang
    Wang, Yen-Po
    Huang, Ming-Chih
    Tsai, Chen-An
    [J]. JOURNAL OF VIBROENGINEERING, 2012, 14 (03) : 1113 - 1121
  • [32] AMBIENT VIBRATION SURVEY OF THE BOSPORUS SUSPENSION BRIDGE
    BROWNJOHN, JMW
    DUMANOGLU, AA
    SEVERN, RT
    BLAKEBOROUGH, A
    [J]. EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 1989, 18 (02): : 263 - 283
  • [33] AMBIENT VIBRATION TESTS OF SUSPENSION BRIDGE - CLOSURE
    ABDELGHAFFAR, AM
    HOUSNER, GW
    [J]. JOURNAL OF THE ENGINEERING MECHANICS DIVISION-ASCE, 1980, 106 (02): : 419 - 419
  • [34] Scour evaluation for foundation of a cable-stayed bridge based on ambient vibration measurements of superstructure
    Chen, Chien-Chou
    Wu, Wen-Hwa
    Shih, Fong
    Wang, Shen-Wei
    [J]. NDT & E INTERNATIONAL, 2014, 66 : 16 - 27
  • [35] Ambient vibration measurements in an irregular building
    Gicev, V.
    Trifunac, M. D.
    Todorovska, M. I.
    Kocaleva, M.
    Stojanova, A.
    Kokalanov, V.
    [J]. SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2021, 141
  • [36] Bridge assessment using forced-vibration testing
    Univ of Plymouth, Devon, United Kingdom
    [J]. J Struct Eng, 2 (161-173):
  • [37] BRIDGE ASSESSMENT USING FORCED-VIBRATION TESTING
    SALAWU, OS
    WILLIAMS, C
    [J]. JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1995, 121 (02): : 161 - 173
  • [38] Finite element model updating of a bridge using ambient vibration measurements with an improved adaptive kriging model
    Qin, Shiqiang
    Han, Shuo
    Liao, Sipeng
    Zhou, Yunlai
    [J]. ENGINEERING OPTIMIZATION, 2024,
  • [39] Identification of flutter derivatives from full-scale ambient vibration measurements of the Clifton Suspension Bridge
    Nikitas, Nikolaos
    Macdonald, John H. G.
    Jakobsen, Jasna B.
    [J]. WIND AND STRUCTURES, 2011, 14 (03) : 221 - 238
  • [40] Ambient vibration and seismic evaluation of a cantilever truss bridge
    Shama, AA
    Mander, JB
    Chen, SS
    Aref, AJ
    [J]. ENGINEERING STRUCTURES, 2001, 23 (10) : 1281 - 1292