Repeatability and Reproducibility of Corneal Epithelial Thickness Mapping With Spectral-Domain Optical Coherence Tomography in Normal and Diseased Cornea Eyes

被引:29
|
作者
Sella, Ruti [1 ]
Zangwill, Linda M. [1 ]
Weinreb, Robert N. [1 ]
Afshari, Natalie A. [1 ]
机构
[1] Univ Calif San Diego, Dept Ophthalmol, Shiley Eye Inst, La Jolla, CA 92093 USA
关键词
LASIK 3-DIMENSIONAL DISPLAY; ARTEMIS; KERATOCONUS; RELIABILITY; ECTASIA; PROFILE;
D O I
10.1016/j.ajo.2018.09.008
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate the performance of the epithelial thickness mapping (ETM) of the iVue spectral domain optical coherence tomography (SD-OCT) device (Optovue Inc, Fremont, California, USA) in normal and diseased cornea eyes. DESIGN: Reliability and validity analysis. METHODS: Sixty eyes of 60 subjects were recruited for the study, which included normal subjects (n = 12) and patients with corneal diseases (12 patients each: dry eye syndrome [DES], contact lens wear, post-laser refractive surgery, and keratoconus). Three repeated scans were acquired on 3 iVue SD-OCTs with device-designated operators from consented subjects. Each subject was scanned on each device. Repeatability (based on random error of repeated scans) and reproducibility (including the random error and the instrument/operator variability) were assessed based on spatial zones derived from a 6 mm -diameter corneal ETM centered on the pupil and compared between the groups. RESULTS: Fifty-nine eyes qualified for final analysis. Seventy-one of 598 acquired scans (11.9%) were excluded owing to scan quality concerns. The percentage of disqualified scans was similar across normal (10.7%) and diseased eyes (12.1%). Of 527 qualified scans, 40 (7.6%) scans required manual edits of the segmentation lines. Repeatability and reproducibility results were similar, indicating minimal device/operator variability for both groups. Repeatability and reproducibility were similar in all subgroups of cornea patients, excluding the DES group, for which reproducibility was significantly lower (range 3.2%-5.5% for DES patients and 1.1%-2.9% for normal subjects). CONCLUSIONS: The iVue SD-OCT provides good corneal ETM repeatability and reproducibility in normal and diseased cornea eyes through all map zones. (C) 2018 Elsevier Inc. All rights reserved.)
引用
收藏
页码:88 / 97
页数:10
相关论文
共 50 条
  • [21] Corneal and Epithelial Thickness Mapping: Comparison of Enhanced Spectral-Domain- and Spectral-Domain-Optical Coherence Tomography
    Georgeon, Cristina
    Marciano, Ilanite
    Cuyaubere, Roxane
    Sandali, Otman
    Bouheraoua, Nacim
    Borderie, Vincent
    [J]. JOURNAL OF OPHTHALMOLOGY, 2021, 2021
  • [22] Repeatability of corneal pachymetry and epithelial thickness measurements with spectral-domain optical coherence tomography (SD-OCT) and correlation to ocular surface parameters
    Vasileia Chatzistergiou
    Argyrios Tzamalis
    Asterios Diafas
    Eirini Oustoglou
    Asimina Mataftsi
    Ioannis Tsinopoulos
    Nikolaos Ziakas
    [J]. International Ophthalmology, 2023, 43 : 3139 - 3148
  • [23] Corneal Epithelial Thickness Mapping by Fourier-Domain Optical Coherence Tomography in Normal, Keratoconic, and Forme Fruste Keratoconus Eyes
    Temstet, Cyril
    Sandali, Otman
    Bouheraoua, Nacim
    Loriaut, Patrick
    Basli, Elena
    Goldschmidt, Pablo L.
    Borderie, Vincent M.
    Laroche, Laurent
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [24] Ocular Surface Epithelial Thickness Evaluation with Spectral-Domain Optical Coherence Tomography
    Francoz, Marlene
    Karamoko, Issouf
    Baudouin, Christophe
    Labbe, Antoine
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (12) : 9116 - 9123
  • [25] Repeatability and Agreement of Swept Source and Spectral Domain Optical Coherence Tomography Evaluations of Thickness Sectors in Normal Eyes
    Lee, Sang Yeop
    Bae, Hyoung Won
    Kwon, Hee Jung
    Seong, Gong Je
    Kim, Chan Yun
    [J]. JOURNAL OF GLAUCOMA, 2017, 26 (02) : E46 - E53
  • [26] Reproducibility of Spectral-Domain Optical Coherence Tomography Total Retinal Thickness Measurements in Mice
    Gabriele, Michelle L.
    Ishikawa, Hiroshi
    Schuman, Joel S.
    Bilonick, Richard A.
    Kim, Jongsick
    Kagemann, Larry
    Wollstein, Gadi
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (12) : 6519 - 6523
  • [27] Assessment of Corneal Epithelial Thickness in Asymmetric Keratoconic Eyes and Normal Eyes Using Fourier Domain Optical Coherence Tomography
    Catalan, S.
    Cadarso, L.
    Esteves, F.
    Salgado-Borges, J.
    Lopez, M.
    Cadarso, C.
    [J]. JOURNAL OF OPHTHALMOLOGY, 2016, 2016
  • [28] Macular thickness measured by spectral-domain optical coherence tomography in healthy Thai eyes
    Choovuthayakorn, Janejit
    Watanachai, Nawat
    Chaikitmongkol, Voraporn
    Patikulsila, Direk
    Kunavisarut, Paradee
    Ittipunkul, Nimitr
    [J]. JAPANESE JOURNAL OF OPHTHALMOLOGY, 2012, 56 (06) : 569 - 576
  • [29] Macular thickness measured by spectral-domain optical coherence tomography in healthy Thai eyes
    Janejit Choovuthayakorn
    Nawat Watanachai
    Voraporn Chaikitmongkol
    Direk Patikulsila
    Paradee Kunavisarut
    Nimitr Ittipunkul
    [J]. Japanese Journal of Ophthalmology, 2012, 56 : 569 - 576
  • [30] Effect of Age on Individual Retinal Layer Thickness in Normal Eyes as Measured With Spectral-Domain Optical Coherence Tomography
    Demirkaya, Nazli
    van Dijk, Hille W.
    van Schuppen, Sanne M.
    Abramoff, Michael D.
    Garvin, Mona K.
    Sonka, Milan
    Schlingemann, Reinier O.
    Verbraak, Frank D.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (07) : 4934 - 4940