Anterior shin muscles CMAP measurements: Normal limits of symmetry and intra- and interobserver reliability

被引:2
|
作者
Willems, Jan [1 ]
Mathieu, Thomas [1 ,2 ]
Gorissen, Dagmar [1 ]
机构
[1] ZNA Middelheim, Dept Phys Med & Rehabil, Antwerp, Belgium
[2] Univ Antwerp, Fac Med & Hlth Sci, Antwerp, Belgium
来源
关键词
Electromyography; Nerve Conduction Studies; Limits of Symmetry; Tibialis Anterior Muscle; Compound Muscle Action Potential; NERVE-CONDUCTION; PERONEAL;
D O I
10.1016/j.cnp.2021.02.001
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Objective: The normal limits of symmetry for the compound muscle action potential of the shin muscles (CMAPshin) have not been determined yet. The goal of this study is to provide extensive data on the limits of symmetry and the reliability of CMAPshin. Methods: The study was conducted in normal healthy males and females. All subjects underwent CMAPshin measurements bilaterally. The median percent differences of right/left amplitude/area, with range of these measurements, were calculated. In addition, the intra- and interobserver reliability was examined in a separate population. Results: The study group consisted of 58 healthy individuals. The median percent right/left difference for amplitude and area were respectively 7.2% (range 0-23.6%) and 5.4% (range 0.7-25.6%). Right/left difference of the amplitude/area of the CMAPshin greater than 24%/26% respectively can be considered as pathological. The Pearson correlation coefficients (r) for the intra-observer reliability amplitude/area are 0.905/0.882 and for the inter-observer reliability are 0.968/0.981. Conclusions: The results confirm symmetry and good intra- and interobserver reliability in CMAPshin measurements. Significance: CMAPshin can be used in practice to estimate axonal loss in case of a foot drop. Data studies examining symmetry of CMAPshin can facilitate in the clinical interpretation of these nerve conduction studies. (C) 2021 International Federation of Clinical Neurophysiology. Published by Elsevier B.V.
引用
收藏
页码:93 / 96
页数:4
相关论文
共 50 条
  • [21] Intra- and interobserver reliability of glenoid fracture classifications by Ideberg, Euler and AO
    Gilbert, F.
    Eden, L.
    Meffert, R.
    Konietschke, F.
    Lotz, J.
    Bauer, L.
    Staab, W.
    BMC MUSCULOSKELETAL DISORDERS, 2018, 19
  • [22] The effect of labeling photo documents in wrist arthroscopies on intra- and interobserver reliability
    Steffen Löw
    Dirk Herold
    Marion Mühldorfer-Fodor
    Thomas Pillukat
    Archives of Orthopaedic and Trauma Surgery, 2012, 132 : 1813 - 1818
  • [23] Intra- and interobserver reliability of glenoid fracture classifications by Ideberg, Euler and AO
    F. Gilbert
    L. Eden
    R. Meffert
    F. Konietschke
    J. Lotz
    L. Bauer
    W. Staab
    BMC Musculoskeletal Disorders, 19
  • [24] Intra- and interobserver variability of ultrasonographic measurements of the thyroid gland in healthy beagles
    Taeymans, O
    Duchateau, L
    Schreurs, E
    Kramer, M
    Daminet, S
    Saunders, JH
    VETERINARY RADIOLOGY & ULTRASOUND, 2005, 46 (02) : 139 - 142
  • [25] INTRA- AND INTEROBSERVER VARIABILITY OF ULTRASONOGRAPHIC MEASUREMENTS OF THE ADRENAL GLANDS IN HEALTHY BEAGLES
    Barberet, Virginie
    Pey, Pascaline
    Duchateau, Luc
    Combes, Anais
    Daminet, Sylvie
    Saunders, Jimmy H.
    VETERINARY RADIOLOGY & ULTRASOUND, 2010, 51 (06) : 656 - 660
  • [26] Abdominal aortic aneurysm measurements for endovascular repair: Intra- and interobserver variability of CT measurements
    Aarts, NJM
    Schurink, GWH
    Kool, LJS
    Bode, PJ
    van Baalen, JM
    Hermans, J
    van Bockel, JH
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 1999, 18 (06) : 475 - 480
  • [27] Reliability of radiographic criteria for trochlear dysplasia: intra- and interobserver analysis on 68 knees
    Remy, F
    Besson, A
    Migaud, H
    Cotten, A
    Gougeon, F
    Duquennoy, A
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 1998, 84 (08): : 728 - 733
  • [28] Reliability and reproducibility of SmartLens®, a contact lens tonometer:: Intra- and interobserver variability.
    Vogel, A
    Beck, S
    Schwenn, O
    Grus, F
    Krummenauer, F
    Pfeiffer, N
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2001, 42 (04) : S821 - S821
  • [29] Intra- and Interobserver Reliability of the New Classification System of Progressive Collapsing Foot Deformity
    Lee, Hee Young
    Mansur, Nacime Salomao Barbachan
    Lalevee, Matthieu
    Dibbern, Kevin N.
    Myerson, Mark S.
    Ellis, Scott J.
    Femino, John E.
    Netto, Cesar de Cesar
    FOOT & ANKLE INTERNATIONAL, 2022, 43 (04) : 582 - 589
  • [30] Comparison of intra- and interobserver reliability with computed and conventional radiography for spinal deformity.
    McGahan, P. J.
    Kuo, C.
    Gupta, M. C.
    JOURNAL OF INVESTIGATIVE MEDICINE, 2007, 55 (01) : S105 - S105