Evaluation of carrier gases for use in high-field asymmetric waveform ion mobility spectrometry

被引:85
|
作者
Barnett, DA
Ells, B
Guevremont, R [1 ]
机构
[1] Natl Res Council Canada, Inst Natl Measurement Stand, Ottawa, ON K1A 0R6, Canada
[2] PE Sciex, Concord, ON, Canada
[3] Chatham Coll, Div Sci, Pittsburgh, PA USA
关键词
D O I
10.1016/S1044-0305(00)00187-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Effects of carrier gas type (N-2, O-2, CO2, N2O, and SF6) on changes in the ratio of high- to low-field ion mobility, K-h/K, of cesium, gramicidin S, tetrahexylammonium, heptadecanoic acid, and aspartic acid in fields of up to 67 Td are presented. The theory of the mobility of ions at high E/N in different gases is discussed. Plots of K-h/K as a function of the ionic energy parameter, E/N, for the five ions in each of the gases were derived from experimental data collected using a high-held asymmetric waveform ion mobility spectrometer. The change in the ratio of high- to low-field ion mobility of cesium in carrier gases of O-2 and N-2 showed excellent agreement with literature values. The behavior of cesium in O-2 and N-2 is used to illustrate that the ratio K-h/K as a function of effective temperature is invariant with gas type as long as the well depth of the interaction potential significantly exceeds thermal energy. From these results, it appears that the well depth of the interaction potential of the heavier ions studied here, including gramicidin S, tetrahexylammonium, and heptadecanoic acid, with bath gases such as N-2 and O-2 is shallow relative to thermal energy. (J Am Soc Mass Spectrom 2000, 11, 1125-1133) (C) 2000 American Society for Mass Spectrometry.
引用
收藏
页码:1125 / 1133
页数:9
相关论文
共 50 条
  • [41] High-Field Asymmetric Waveform Ion Mobility Spectrometry Interface Enhances Parallel Reaction Monitoring on an Orbitrap Mass Spectrometer
    Deng, Weixian
    Sha, Jihui
    Xue, Fanglei
    Jami-Alahmadi, Yasaman
    Plath, Kathrin
    Wohlschlegel, James
    ANALYTICAL CHEMISTRY, 2022, 94 (46) : 15939 - 15947
  • [42] Predicting Compensation Voltage for Singly-charged Ions in High-Field Asymmetric Waveform Ion Mobility Spectrometry (FAIMS)
    Aksenov, Alexander A.
    Kapron, James
    Davis, Cristina E.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2012, 23 (10) : 1794 - 1798
  • [43] High-field asymmetric waveform ion mobility spectrometry for xylene isomer separation assisted by helium-chemical modifiers
    Du, Xiaoxia
    Wang, Yifei
    Zeng, Hongda
    Zeng, Hao
    Chen, Zhencheng
    Li, Hua
    ANALYTICAL METHODS, 2022, 14 (45) : 4649 - 4658
  • [44] Solvent vapor effects in planar high-field asymmetric waveform ion mobility spectrometry: Solvent trends and temperature effects
    Rorrer, Leonard C., III
    Yost, Richard A.
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2015, 378 : 336 - 346
  • [45] Comparison of high-field asymmetric waveform ion mobility spectrometry with GC methods in analysis of haloacetic acids in drinking water
    Gabryelski, W
    Wu, FW
    Froese, KL
    ANALYTICAL CHEMISTRY, 2003, 75 (10) : 2478 - 2486
  • [46] Gas modifier assisted re-circulation mode high-field asymmetric waveform ion mobility spectrometry (FAIMS)
    Ruan, Zhiming
    Chen, Chilai
    Chen, Ran
    Liu, Youjiang
    Wang, Xiaozhi
    Li, Shan
    Yu, Jianwen
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2017, 414 : 8 - 12
  • [47] Global Phosphoproteome Analysis Using High-Field Asymmetric Waveform Ion Mobility Spectrometry on a Hybrid Orbitrap Mass Spectrometer
    Muehlbauer, Laura K.
    Hebert, Alexander S.
    Westphall, Michael S.
    Shishkova, Evgenia
    Coon, Joshua J.
    ANALYTICAL CHEMISTRY, 2020, 92 (24) : 15959 - 15967
  • [48] Distortion of ion structures by field asymmetric waveform ion mobility spectrometry
    Shvartsburg, Alexandre A.
    Li, Fumin
    Tang, Keqi
    Smith, Richard D.
    ANALYTICAL CHEMISTRY, 2007, 79 (04) : 1523 - 1528
  • [49] Analysis of paralytic shellfish toxins using high-field asymmetric waveform ion mobility spectrometry with liquid chromatography-mass spectrometry
    Daniel G. Beach
    Jeremy E. Melanson
    Randy W. Purves
    Analytical and Bioanalytical Chemistry, 2015, 407 : 2473 - 2484
  • [50] Removal of metabolite interference during liquid chromatography/tandem mass spectrometry using high-field asymmetric waveform ion mobility spectrometry
    Kapron, JT
    Jemal, M
    Duncan, G
    Kolakowski, B
    Purves, R
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (14) : 1979 - 1983