On-X mitral valve replacement: a single-centre experience in 318 patients

被引:11
|
作者
Murana, Giacomo [1 ]
Alfonsi, Jacopo [1 ]
Savini, Carlo [1 ]
Mariani, Carlo [1 ]
Coppola, Giuditta [1 ]
Lo Coco, Valeria [1 ]
Pilato, Emanuele [1 ]
Pacini, Davide [1 ]
Di Bartolomeo, Roberto [1 ]
机构
[1] Univ Bologna, S Orsola Hosp, Dept Cardiothorac Surg, Bologna, Italy
关键词
Mitral; On-X; Mitral valve replacement; Mechanical prosthesis; Long term; MECHANICAL HEART-VALVE; REDUCED ANTICOAGULATION; PYROLYTIC CARBON; RISK;
D O I
10.1093/icvts/ivy184
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES: If mitral valve repair is not feasible, mitral valve replacement remains the only option. Based on our overall experience with the On-X mitral valve, the aim of this study was to investigate early and late outcomes after mitral valve replacement using this latest generation prosthesis. METHODS: From 1998 to 2016, 600 patients received an On-X prosthesis in the mitral position. Of them, we excluded all patients who had combined aortic procedures and retrospectively analysed 318 consecutive patients who had a mitral valve replacement. Associated procedures (53.5%) were tricuspid valve repair, coronary artery bypass graft and the maze procedure. The mean follow-up time was 5.6 +/- 4.0 years. RESULTS: The overall hospital mortality rate was 4.4%, including acute cases of ischaemic mitral regurgitation (9.4%) and infective endocarditis (9.4%). Survival rates at 1, 3, 5 and 10 years were 97.8 +/- 1.0%, 92.4 +/- 1.7%, 88.4 +/- 2.2% and 70.9 +/- 4.0%, respectively. Independent predictors of late mortality were hypertension [ hazard ratio (HR) 1.91; P = 0.027], chronic obstructive pulmonary disease (HR 2.91; P = 0.003) and chronic renal failure (HR 5.27; P < 0.001). Freedom from reoperation was 99.3 +/- 0.5%, 98.4 +/- 0.8%, 97.2 +/- 1.2% and 92.5 +/- 2.4% at 1, 3, 5 and 10 years, respectively. At follow-up, 8.5% events were recognized as thromboembolic or haemorrhagic events; freedom from events related to anticoagulation therapy at 1, 3, 5 and 10 years was 99.0 +/- 0.6%, 96.8 +/- 1.1%, 93.7 +/- 1.8% and 89.0 +/- 2.7%, respectively. CONCLUSIONS: According to the results of this observational study, the unique design of the On-X valve works well with mitral valve diseases of various aetiologies, especially in cases with an unfavourable anatomy. This prosthesis also guarantees safe long-term durability associated with a low incidence of thromboembolism.
引用
收藏
页码:836 / 841
页数:6
相关论文
共 50 条
  • [21] Should more patients be offered repair for mitral valve endocarditis? a single-centre 15-year experience
    Clarissa Ng Yin Ling
    David Bleetman
    Soumik Pal
    Hing Chi Kristie Leung
    Habib Khan
    Donald Whitaker
    Olaf Wendler
    Ranjit Deshpande
    Max Baghai
    Journal of Cardiothoracic Surgery, 17
  • [22] Should more patients be offered repair for mitral valve endocarditis? a single-centre 15-year experience
    Ng Yin Ling, Clarissa
    Bleetman, David
    Pal, Soumik
    Leung, Hing Chi Kristie
    Khan, Habib
    Whitaker, Donald
    Wendler, Olaf
    Deshpande, Ranjit
    Baghai, Max
    JOURNAL OF CARDIOTHORACIC SURGERY, 2022, 17 (01)
  • [23] Surgical treatment for isolated mitral valve endocarditis: a 16-year single-centre experience
    Perrotta, Sossio
    Frojd, Victoria
    Lepore, Vincenzo
    Schersten, Henrik
    Jeppsson, Anders
    Svensson, Gunnar
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2018, 53 (03) : 576 - 581
  • [24] Unilateral pulmonary oedema after minimally invasive mitral valve surgery: a single-centre experience
    Renner, Jochen
    Lorenzen, Ulf
    Borzikowsky, Christoph
    Schoeneich, Felix
    Cremer, Jochen
    Haneya, Assad
    Hensler, Johannes
    Panholzer, Bernd
    Huenges, Katharina
    Broch, Ole
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2018, 53 (04) : 764 - 770
  • [25] Percutaneous complete repair of failed mitral valve prosthesis: simultaneous closure of mitral paravalvular leaks and transcatheter mitral valve implantation - single-centre experience
    Kliger, Chad
    Angulo, Rocio
    Maranan, Leandro
    Kumar, Robert
    Jelnin, Vladimir
    Kronzon, Itzhak
    Fontana, Gregory P.
    Plestis, Konstadinos
    Patel, Nirav
    Perk, Gila
    Ruiz, Carlos E.
    EUROINTERVENTION, 2015, 10 (11) : 1336 - 1345
  • [26] A SINGLE CENTRE EXPERIENCE WITH PERCUTANEOUS MITRAL VALVE REPAIR
    Cohen, G.
    Cohen, E. A.
    Wolf, R.
    Wong, S.
    Hockman, E.
    Laflamme, C.
    CANADIAN JOURNAL OF CARDIOLOGY, 2013, 29 (10) : S365 - S365
  • [27] At home enzyme replacement therapy for patients with lysosomal disorders: A single-centre experience
    Ochoa-Ferraro, Antonio F.
    Watkins, Kelly
    Dayus-Reason, Andie
    Bolton, Shaun
    Dawson, Charlotte
    Geberhiwot, Tarekegn
    MOLECULAR GENETICS AND METABOLISM, 2023, 138 (02) : 95 - 95
  • [28] Single-centre experience of mitral valve surgery via right lateral mini-thoracotomy in octogenarians
    Minol, Philipp
    Akhyari, Payam
    Boeken, Udo
    Kamiya, Hiroyuki
    Weinreich, Tobias
    Sixt, Stephan
    Gramsch-Zabel, Hildegard
    Lichtenberg, Artur
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2016, 22 (03) : 287 - 290
  • [29] A South Africa tertiary centre experience with redo mitral valve replacement
    Kistan, D.
    Booysen, M.
    Alexander, G.
    Madiba, T. E.
    SOUTH AFRICAN JOURNAL OF SURGERY, 2022, 60 (01) : 44 - 48
  • [30] Surgical treatment of tricuspid valve endocarditis: a single-centre experience
    Capoun, R.
    Thomas, M.
    Caputo, M.
    Asimakopoulos, G.
    PERFUSION-UK, 2010, 25 (03): : 169 - 173