On-X mitral valve replacement: a single-centre experience in 318 patients

被引:11
|
作者
Murana, Giacomo [1 ]
Alfonsi, Jacopo [1 ]
Savini, Carlo [1 ]
Mariani, Carlo [1 ]
Coppola, Giuditta [1 ]
Lo Coco, Valeria [1 ]
Pilato, Emanuele [1 ]
Pacini, Davide [1 ]
Di Bartolomeo, Roberto [1 ]
机构
[1] Univ Bologna, S Orsola Hosp, Dept Cardiothorac Surg, Bologna, Italy
关键词
Mitral; On-X; Mitral valve replacement; Mechanical prosthesis; Long term; MECHANICAL HEART-VALVE; REDUCED ANTICOAGULATION; PYROLYTIC CARBON; RISK;
D O I
10.1093/icvts/ivy184
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES: If mitral valve repair is not feasible, mitral valve replacement remains the only option. Based on our overall experience with the On-X mitral valve, the aim of this study was to investigate early and late outcomes after mitral valve replacement using this latest generation prosthesis. METHODS: From 1998 to 2016, 600 patients received an On-X prosthesis in the mitral position. Of them, we excluded all patients who had combined aortic procedures and retrospectively analysed 318 consecutive patients who had a mitral valve replacement. Associated procedures (53.5%) were tricuspid valve repair, coronary artery bypass graft and the maze procedure. The mean follow-up time was 5.6 +/- 4.0 years. RESULTS: The overall hospital mortality rate was 4.4%, including acute cases of ischaemic mitral regurgitation (9.4%) and infective endocarditis (9.4%). Survival rates at 1, 3, 5 and 10 years were 97.8 +/- 1.0%, 92.4 +/- 1.7%, 88.4 +/- 2.2% and 70.9 +/- 4.0%, respectively. Independent predictors of late mortality were hypertension [ hazard ratio (HR) 1.91; P = 0.027], chronic obstructive pulmonary disease (HR 2.91; P = 0.003) and chronic renal failure (HR 5.27; P < 0.001). Freedom from reoperation was 99.3 +/- 0.5%, 98.4 +/- 0.8%, 97.2 +/- 1.2% and 92.5 +/- 2.4% at 1, 3, 5 and 10 years, respectively. At follow-up, 8.5% events were recognized as thromboembolic or haemorrhagic events; freedom from events related to anticoagulation therapy at 1, 3, 5 and 10 years was 99.0 +/- 0.6%, 96.8 +/- 1.1%, 93.7 +/- 1.8% and 89.0 +/- 2.7%, respectively. CONCLUSIONS: According to the results of this observational study, the unique design of the On-X valve works well with mitral valve diseases of various aetiologies, especially in cases with an unfavourable anatomy. This prosthesis also guarantees safe long-term durability associated with a low incidence of thromboembolism.
引用
收藏
页码:836 / 841
页数:6
相关论文
共 50 条
  • [1] Single-centre experience with mitral valve repair in asymptomatic patients with severe mitral valve regurgitation†
    van Leeuwen, Wouter J.
    Head, Stuart J.
    de Groot-de Laat, Lotte E.
    Geleijnse, Marcel L.
    Bogers, Ad J. J. C.
    Van Herwerden, Lex A.
    Kappetein, A. Pieter
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2013, 16 (06) : 731 - 736
  • [2] Single-centre experience with mitral valve repair in asymptomatic patients with severe mitral valve regurgitation CONFERENCE DISCUSSION
    Borger, M.
    Van Leeuwen
    Mesana, T.
    Sarkar, K.
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2013, 16 (06) : 736 - 737
  • [3] Robotic mitral valve repair: a European single-centre experience
    Navarra, Emiliano
    Mastrobuoni, Stefano
    De Kerchove, Laurent
    Glineur, David
    Watremez, Christine
    Van Dyck, Michel
    El Khoury, Gebrine
    Noirhomme, Philippe
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2017, 25 (01) : 62 - 67
  • [4] EXPERIENCE WITH IN ON-X PROSTHESIS IN HEART VALVE REPLACEMENT
    Sazonenkov, M. A.
    Basarab, D. A.
    Krivorot, S. S.
    Korneluk, M. N.
    VESTNIK TRANSPLANTOLOGII I ISKUSSTVENNYH ORGANOV, 2010, 12 (04): : 39 - 43
  • [5] Outcome after redo-mitral valve replacement in adult patients: a 10-year single-centre experience
    Vohra, Hunaid A.
    Whistance, Robert N.
    Roubelakis, Apostolos
    Burton, Andrew
    Barlow, Clifford W.
    Tsang, Geoffrey M. K.
    Livesey, Steve A.
    Ohri, Sunil K.
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2012, 14 (05) : 575 - 579
  • [6] Aortic valve replacement: assessment of quality - a single-centre experience
    Schroeder, Erwin
    Bihin, Benoit
    Richard, Melanie
    Guillaume, Laurent
    Cuvelier, Nadege
    Michaux, Isabelle
    Dincq, Anne-Sophie
    Guedes, Antoine
    Eucher, Philippe
    Buche, Michel
    ACTA CARDIOLOGICA, 2017, 72 (01) : 121 - 121
  • [7] Is tricuspid annuloplasty increasing surgical mortality and morbidity during mitral valve replacement? A single-centre experience
    Verdonk, Constance
    Darmon, Arthur
    Cimadevilla, Claire
    Lepage, Laurent
    Raffoul, Richard
    Nataf, Patrick
    Vahanian, Alec
    Messika-Zeitoun, David
    ARCHIVES OF CARDIOVASCULAR DISEASES, 2018, 111 (8-9) : 480 - 486
  • [8] Benefits of On-X Mitral Valve Replacement in Cases of Infective Endocarditis
    Shiraishi, Manabu
    Arai, Hiroki
    Tokunaga, Shigeto
    Teshima, Kengo
    Kimura, Naoyuki
    Yamaguchi, Atsushi
    JOURNAL OF CARDIAC SURGERY, 2024, 2024
  • [9] Rapid-deployment aortic valve replacement for patients with bicuspid aortic valve: a single-centre experience
    Coti, Iuliana
    Werner, Paul
    Kaider, Alexandra
    Mach, Markus
    Kocher, Alfred
    Laufer, Guenther
    Andreas, Martin
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2022, 62 (04)
  • [10] Feasibility of preservation of subvalvular apparatus in mitral valve replacement with the On-X mechanical valve
    Tanaka, Hiroshi
    Yamshita, Teruo
    Okada, Kenji
    Nakagiri, Keitaro
    Kawanishi, Yujiro
    Okita, Yutaka
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2006, 132 (06): : 1470 - 1471