Optimization of the thoron progeny compensation system of a thoron calibration chamber

被引:3
|
作者
Li, Weiwei [1 ]
Zhou, Qingzhi [1 ]
He, Zhengzhong [1 ]
Li, Guiyuan [1 ]
Liu, Wei [1 ]
机构
[1] Univ South China, Sch Nucl Sci & Technol, 28 Changshengxi Rd, Hengyang 421001, Hunan, Peoples R China
基金
中国国家自然科学基金;
关键词
Thoron progeny; Control method; Thoron progeny output rate; SIZE;
D O I
10.1007/s10967-020-07180-y
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The long-term stability and homogeneity of thoron progeny are key to the performance of a thoron calibration chamber, which is vital to quality assurance in measuring thoron progeny. It is difficult to build a stable and high level of thoron progeny because the half-life of Pb-212 is long. Thus, a stable and efficient compensation system is necessary to compensate for the loss of thoron progeny caused by sampling, decay, and wall deposition. In this paper, a thoron progeny compensation system at the University of South China is optimized, and a suitable ventilation rate regulation method is developed that can effectively improve the activity level and stability of output rate for thoron progeny. The experimental results show that the Pb-212 activity output rate increases by 28% and that the output rate is more stable. Under these conditions, the time for the output rate of ThB activity to reach stability is reduced by 33%, and for ThC, the time to reach stability is reduced by 40%. Furthermore, the concentration ratios of ThC and ThB range from 0 to 0.82.
引用
收藏
页码:1255 / 1263
页数:9
相关论文
共 50 条
  • [21] Comparative analysis of radon, thoron and thoron progeny concentration measurements
    Janik, Miroslaw
    Tokonami, Shinji
    Kranrod, Chutima
    Sorimachi, Atsuyuki
    Ishikawa, Tetsuo
    Hosoda, Masahiro
    Mclaughlin, James
    Chang, Byung-Uck
    Kim, Yong Jae
    JOURNAL OF RADIATION RESEARCH, 2013, 54 (04) : 597 - 610
  • [22] An integrated approach for the assessment of the thoron progeny exposures using direct thoron progeny sensors
    Mishra, R.
    Prajith, R.
    Sapra, B. K.
    Mayya, Y. S.
    RADIATION PROTECTION DOSIMETRY, 2010, 141 (04) : 363 - 366
  • [23] NEUTRALIZATION OF THORON PROGENY IN GASES
    CHENG, YS
    YU, CC
    TUNG, CJ
    HOPKE, PK
    HEALTH PHYSICS, 1994, 67 (02): : 155 - 161
  • [24] ELECTRICAL CHARGE OF THORON PROGENY
    BIGU, J
    RADIATION PROTECTION DOSIMETRY, 1989, 28 (03) : 215 - 217
  • [25] INADEQUACY OF THORON DOSE CALCULATIONS FROM THORON PROGENY MEASUREMENT ALONE
    Lane-Smith, D.
    Wong, F. K.
    RADIATION PROTECTION DOSIMETRY, 2016, 171 (02) : 179 - 180
  • [26] Calibration of thoron monitors
    Qiu, Shoukang
    2003, Science Press (26):
  • [27] Deposition and spatial variation of thoron decay products in a thoron experimental house using the Direct Thoron Progeny Sensors
    Mishra, R.
    Joshi, M.
    Meisenberg, O.
    Gierl, S.
    Prajith, R.
    Kanse, S. D.
    Rout, R.
    Sapra, B. K.
    Mayya, Y. S.
    Tschiersch, J.
    JOURNAL OF RADIOLOGICAL PROTECTION, 2017, 37 (02) : 379 - 389
  • [28] INDOOR RADON, THORON AND THEIR PROGENY CONCENTRATIONS IN HIGH THORON RURAL SERBIA ENVIRONMENTS
    Zunic, Zora S.
    Stojanovska, Z.
    Veselinovic, N.
    Mishra, R.
    Yarmoshenko, I. V.
    Sapra, B. K.
    Ishikawa, T.
    Omori, Y.
    Curguz, Z.
    Bossew, P.
    Udovicic, V.
    Ramola, R. C.
    RADIATION PROTECTION DOSIMETRY, 2017, 177 (1-2) : 36 - 39
  • [29] DISTRIBUTIONS OF THORON PROGENY CONCENTRATIONS IN DWELLINGS
    YAMASAKI, T
    GUO, Q
    IIDA, T
    RADIATION PROTECTION DOSIMETRY, 1995, 59 (02) : 135 - 140
  • [30] Thoron progeny concentrations in living space
    Yamasaki, T
    Iida, T
    IRPA9 - 1996 INTERNATIONAL CONGRESS ON RADIATION PROTECTION / NINTH INTERNATIONAL CONGRESS OF THE INTERNATIONAL RADIATION PROTECTION ASSOCIATION, PROCEEDINGS, VOL 2, 1996, : B47 - B49