Persistent residual shunts after atrial septal defect closure with the Amplatzer septal occluder

被引:0
|
作者
Hiremath, Gurumurthy [1 ]
March, S. Kimara [2 ]
Bass, John L. [1 ]
机构
[1] Univ Minnesota, Masonic Childrens Hosp, Dept Pediat, Div Pediat Cardiol, 2450 Riverside Ave, Minneapolis, MN 55454 USA
[2] Univ Minnesota Phys, Dept Cardiol, Minneapolis, MN USA
关键词
Atrial septal defect; Residual shunt; Amplatzer septal occluder; TRANSCATHETER CLOSURE; DEVICE CLOSURE; EROSION; RISK;
D O I
10.1016/j.ppedcard.2021.101462
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Transcatheter closure of atrial septal defects (ASD) is a common procedure. Amplatzer Septal Occluder (ASO) was the first device to receive FDA approval for this procedure in December 2001 and is commonly used for this indication. Persistent residual shunts are infrequent following ASD device closure with the ASO device. We report two adult patients with persistent and remarkably similar residual shunts that occurred anteriorly between the discs of the device as it splayed around the aorta. We speculate that oversizing ASO devices could lead to a residual shunt between the discs.
引用
收藏
页数:4
相关论文
共 50 条
  • [41] Transcatheter closure of atrial septal defects in adults with the Amplatzer septal occluder
    Dhillon, R
    Thanopoulos, B
    Tsaousis, G
    Triposkiadis, F
    Kyriakidis, M
    Redington, A
    HEART, 1999, 82 (05) : 559 - 562
  • [42] Cardiac Erosion after the Transcatheter Closure of Atrial Septal Defect Using Amplatzer Septal Occluder: Japanese Nationwide Experience
    Akagi, Teiji
    Yazaki, Satoshi
    Tomita, Hideshi
    Takayama, Morimasa
    Hara, Hidehiko
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 68 (18) : B249 - B249
  • [43] Implantation of the Amplatzer Septal Occluder in patients with borderline atrial septal defect
    Pinte, F.
    Iacob, M.
    Tintoiu, I.
    Goleanu, V.
    Filip, S.
    Lobont, B.
    Cristian, G.
    Postolea, E.
    EUROPEAN HEART JOURNAL, 2006, 27 : 798 - 798
  • [44] Myocardial damage after transcatheter atrial septal defect closure depends on size of amplatzer septal occluder and is age independent
    Tárnok, A
    Bocsi, J
    Lenz, D
    Osmancik, P
    Häusler, HJ
    Schneider, P
    Dähnert, I
    CYTOMETRY PART A, 2005, 64A (02) : 125 - 125
  • [45] Cardiac magnetic resonance documentation of a double atrial septal defect before and after percutaneous closure with an Amplatzer septal occluder
    Duncan, Rae F.
    Teo, Karen S. L.
    Worthley, Stephen G.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2008, 130 (01) : E42 - E43
  • [46] Severe Mechanical Hemolysis After Transcatheter Closure of a Traumatic Ventricular Septal Defect Using the Amplatzer Atrial Septal Occluder
    Tang, Liang
    Tang, Jian-jun
    Fang, Zhen-fei
    Hu, Xin-qun
    Shen, Xiang-qian
    Zhou, Sheng-hua
    INTERNATIONAL HEART JOURNAL, 2016, 57 (04) : 519 - 521
  • [47] Failed closure of a ventricular septal defect with an Amplatzer occluder
    Wippermann, Jens
    Hoppe, Uta C.
    Sreeram, Narayanswami
    Wahlers, Thorsten
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2010, 10 (02) : 320 - 321
  • [48] Long-Term Follow Up of Secundum Atrial Septal Defect Closure with the Amplatzer Septal Occluder
    Knepp, Marc D.
    Rocchini, Albert P.
    Lloyd, Thomas R.
    Aiyagari, Ranjit M.
    CONGENITAL HEART DISEASE, 2010, 5 (01) : 32 - 37
  • [49] Simultaneous transcatheter closure of an atrial septal defect with an Amplatzer septal occluder and radiofrequency ablation of an accessory connection
    Kannankeril, PJ
    Wax, DF
    Deal, BJ
    Johnsrude, CL
    Duffy, CE
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2000, 51 (01) : 55 - 57
  • [50] Assessment of right atrial and right ventricular size in children after percutaneous closure of secundum atrial septal defect with Amplatzer septal occluder
    Kucinska, Beata
    Werner, Boena
    Wroblewska-Kaluzewska, Maria
    ARCHIVES OF MEDICAL SCIENCE, 2010, 6 (04) : 567 - 572