Probe measurements in a nonstationary plasma

被引:8
|
作者
Bliokh, Yu. P. [1 ]
Brodsky, Yu. L. [1 ]
Chashka, Kh. B. [1 ]
Felsteiner, J. [1 ]
Slutsker, Ya. Z. [1 ]
机构
[1] Technion Israel Inst Technol, Dept Phys, IL-32000 Haifa, Israel
关键词
D O I
10.1063/1.2838227
中图分类号
O59 [应用物理学];
学科分类号
摘要
Single and double probes are simple and common tools for plasma measurements. In the case of nonstationary plasmas, the values of the plasma density obtained with these tools may differ significantly from the correct values measured, e.g., by microwave methods. The reason for such discrepancy could be the Bohm criterion failure during the plasma transition to the steady state. Indeed, the Bohm criterion, which is commonly used as a boundary condition at the plasma-sheath edge, directly determines the ion saturation current to the probe surface. The transition-time duration is studied and explained quantitatively for various plasmas produced by a version of a ferroinductor-coupled plasma source, which has its magnetic core fully immersed in the plasma. Corresponding conversion factors for probe measurements have been evaluated. Also, the influence of a certain amount of "hot" non-Maxwellian electrons on probe characteristics has been investigated. (C) 2008 American Institute of Physics.