Study on the performance and free cooling potential of a R32 loop thermosyphon system used in data center

被引:20
|
作者
Zou, Sikai [1 ]
Zhang, Quan [1 ]
Yue, Chang [2 ]
Wang, Jiaqiang [2 ]
Du, Sheng [1 ]
机构
[1] Hunan Univ, Coll Civil Engn, Changsha 410082, Peoples R China
[2] Cent South Univ, Sch Energy Sci & Engn, Changsha 410083, Peoples R China
关键词
Data center; Loop thermosyphon; R32; Free cooling; HEAT-PIPE SYSTEM; ENERGY-SAVING ANALYSIS; SIDE ECONOMIZERS; AIR; SIMULATION;
D O I
10.1016/j.enbuild.2021.111682
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Loop thermosyphon system is an efficient cooling system for energy saving in data center. It is necessary to investigate the performance of the loop thermosyphon system filled with alternative refrigerants to prompt its application. In this paper, a R32 loop thermosyphon system is experimentally investigated in an enthalpy difference laboratory for its performance. R22 and R134a are also used for comparison. The results show that the optimal filling ratio of R22, R134a and R32 is the same (37.3%). At the optimal filling ratio, the flow stability of R32 is obviously better than those of R22 and R134a. When cold water temperatures are 10-22 degrees C, the cooling capacity of R32 is 5.4-15.6% higher than those of R22 and R134a. After controlling extractor fans, the energy efficiency ratio of R32 is 4.9-206.6% higher than those of R22 and R134a. Moreover, the free cooling potentials of the three refrigerants in five typical climate cities across China are analyzed and compared. Compared with R22 and R134a, R32 has 3.6-11.0% and 18.5-26.7% higher free cooling percentages and annual energy efficiency ratio, respectively; and its annual average partial power usage effectiveness is 0.0012-0.0017 lower than that of other two refrigerants. (C) 2021 Elsevier B.V. All rights reserved.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Cycle performance study on R32/R125/R161 as an alternative refrigerant to R407C
    Han, X. H.
    Wang, Q.
    Zhu, Z. W.
    Chen, G. M.
    [J]. APPLIED THERMAL ENGINEERING, 2007, 27 (14-15) : 2559 - 2565
  • [42] Experiment study of an enhanced vapor injection refrigeration/heat pump system using R32
    Xu Shuxue
    Ma Guoyuan
    Liu Qi
    Liu Zhongliang
    [J]. INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2013, 68 : 103 - 109
  • [43] Experimental and simulation study of the performance of a desiccant loop cooling system
    Venkatesh, R.
    Ganesh, Madhu
    Suriyaprakash, S.
    Deva Surya, S. E.
    Ashok Kumar, L.
    Rudramoorthy, R.
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2021, 235 (08) : 1914 - 1932
  • [44] Energy performance evaluation in a data center with water-side free cooling
    Mi, Ranran
    Bai, Xuelian
    Xu, Xin
    Ren, Fei
    [J]. ENERGY AND BUILDINGS, 2023, 295
  • [45] Numerical Investigations of the Cooling Performance of an R410A Closed-Loop Spray Cooling System
    Yang, Wenbo
    Sang, Xuehao
    Chen, Bin
    Li, Dong
    [J]. ENERGIES, 2024, 17 (02)
  • [46] Seasonal ground cold energy storage potential for data center cooling using thermosyphon: A comparative study of five cities in Canada for carbon footprint reduction
    Tareen, Muhammad S. K.
    Zueter, Ahmad F.
    Zolfagharroshan, Mohammad
    Xu, Minghan
    Sasmito, Agus P.
    [J]. JOURNAL OF ENERGY STORAGE, 2024, 84
  • [47] Experimental Study on Performance of Flash-tank Vapor Injection Air-Source Heat Pump System with Refrigerant R32
    Xue Jie
    Guo Xianmin
    Xue Liping
    [J]. PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON APPLIED ENERGY, 2017, 142 : 950 - 956
  • [48] PERFORMANCE ANALYSIS OF AN AIR COMPRESSION REFRIGERATION SYSTEM FOR DATA CENTER COOLING
    RONG, Weilai
    MA, Guoyuan
    HAN, Cong
    XU, Shuxue
    SUN, Shangyu
    YU, Guoxin
    [J]. Thermal Science, 2024, 28 (05): : 3777 - 3788
  • [49] Study on the operation strategy of the water cooling system in the single-phase immersion cooling data center considering cooling tower performance
    Wang, Chenxu
    Yu, Hang
    Xian, Lei
    Liu, Guoqiu
    Chen, Lei
    Tao, Wen-Quan
    [J]. Energy and Buildings, 2024, 324
  • [50] Theoretical Study on Cryogen Spray Cooling in Laser Treatment of Ota's Nevus: Comparison and Optimization of R134a, R404A and R32
    Tian, Jiameng
    Chen, Bin
    Zhou, Zhifu
    Li, Dong
    [J]. ENERGIES, 2020, 13 (21)