Charge carriers and triplets in OLED devices studied by Electrically Detected magnetic resonance

被引:0
|
作者
Pawlik, Thomas D. [1 ]
Kondakova, Marina E. [1 ]
Giesen, David J. [1 ]
Deaton, Joseph C. [1 ]
Kondakov, Denis Y. [1 ]
机构
[1] Eastman Kodak Co, Rochester, NY 14652 USA
关键词
D O I
暂无
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Organic Light-Emitting Diodes (OLEDs) were investigated with an Electron Paramagnetic Resonance (EPR) technique that uses the effective device conductance as the detection channel. This technique enables its to identify and study charge carriers and triplet excitons with high sensitivity. Using a series of model devices, we demonstrate that this type of spectroscopy provides information about triplet energy tran. fer and the location of the recombination zone. The fundamental understanding about the extent of the recombination zone in various OLED architectures helps its to design devices with improved performance.
引用
收藏
页码:613 / 616
页数:4
相关论文
共 50 条
  • [31] Electrically detected magnetic resonance in undoped polyacetylene and polyaniline
    Technische Universitaet Muenchen, Garching, Germany
    Phys Status Solidi A, 2 (713-721):
  • [32] Wafer-Level Electrically Detected Magnetic Resonance: Magnetic Resonance in a Probing Station
    McCrory, Duane J.
    Anders, Mark A.
    Ryan, Jason T.
    Shrestha, Pragya R.
    Cheung, Kin P.
    Lenahan, Patrick M.
    Campbell, Jason P.
    IEEE TRANSACTIONS ON DEVICE AND MATERIALS RELIABILITY, 2018, 18 (02) : 139 - 143
  • [33] Chlorophyll triplets of Photosystem II reaction centre detected by absorbance detected magnetic resonance (ADMR)
    Vácha, F
    Owen, G
    Hoff, AJ
    PHOTOSYNTHESIS: MECHANISMS AND EFFECTS, VOLS I-V, 1998, : 1065 - 1068
  • [34] Pulsed magnetic resonance of Alq3 OLED detected by electroluminescence
    Comande, F.
    Ansermet, J-Ph
    SYNTHETIC METALS, 2013, 173 : 40 - 42
  • [35] THEORY OF ELECTRICALLY DETECTED MAGNETIC RESONANCE OF TRIPLET CENTERS IN SILICON
    Barabanov, A. V.
    Horoshok, R. A.
    UKRAINIAN JOURNAL OF PHYSICS, 2007, 52 (10): : 973 - 979
  • [36] Quanitative Electrically Detected Magnetic Resonance for Device Reliability Studies
    Cochrane, Corey J.
    Anders, Mark
    Mutch, Mike
    Lenahan, Patrick
    2014 IEEE INTERNATIONAL INTEGRATED RELIABILITY WORKSHOP FINAL REPORT (IIRW), 2014, : 6 - 9
  • [37] Lock-in detection for pulsed electrically detected magnetic resonance
    Hoehne, Felix
    Dreher, Lukas
    Behrends, Jan
    Fehr, Matthias
    Huebl, Hans
    Lips, Klaus
    Schnegg, Alexander
    Suckert, Max
    Stutzmann, Martin
    Brandt, Martin S.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (04):
  • [38] Pulsed low-field electrically detected magnetic resonance
    Dreher, L.
    Hoehne, F.
    Morishita, H.
    Huebl, H.
    Stutzmann, M.
    Itoh, K. M.
    Brandt, M. S.
    PHYSICAL REVIEW B, 2015, 91 (07):
  • [39] Broadband electrically detected magnetic resonance using adiabatic pulses
    Hrubesch, F. M.
    Braunbeck, G.
    Voss, A.
    Stutzmann, M.
    Brandt, M. S.
    JOURNAL OF MAGNETIC RESONANCE, 2015, 254 : 62 - 69
  • [40] Electrically detected magnetic resonance studies of phosphorus doped diamond
    Graf, T
    Brandt, MS
    Nebel, CE
    Stutzmann, M
    Koizumi, S
    PHYSICA B-CONDENSED MATTER, 2001, 308 : 593 - 597