retinol bmding protein;
vitamin A deficiency;
enzyme inummoassay;
vitamin A status;
serum retinol;
D O I:
暂无
中图分类号:
R15 [营养卫生、食品卫生];
TS201 [基础科学];
学科分类号:
100403 ;
摘要:
Background: Retinol-binding protein (RBP) was chosen as a surrogate marker for retinol because of the close correspondence between retinol and RBP. Objective: To meet the need for rapid, cost-effective determination of vitamin A status in populations, a quantitative enzyme immunoassay (EIA) for detection of RBP was developed. Design: The resulting RBP EIA, a competitive assay, uses RBP adsorbed to microtest strip wells to compete with RBP in serum. The assay takes approximate to40 min. Results: With a reference panel of sera, test accuracy was found to be within 4% of expected values through the calibrated range of 0.48-1.92 mumol RBP/L (10-40 mug RBP/mL). Intraassay and interassay variability averaged 6.7% and 8.9%, respectively. Specificity testing showed no interference from other serum proteins, prealbumin, rheumatoid factor, bilirubin, estrogen, or C-reactive protein. The REP EIA provided linear results between 0.43 and 1.80 mumol RBP/L (9 and 38 mug RBP/mL). Preliminary laboratory evaluations indicated that the RBP EIA correlates well with radial immunodiffusion for RBP and with HPLC for retinol, the current reference standard. A field evaluation in a population at risk for vitamin A deficiency (VAD) resulted in close correlation between RBP EIA measures and retinol measures by HPLC (R-2 = 0.82). Conclusions: The RBP EIA is as reliable in estimating VAD as is HPLC retinol. After successful validations, the test should enable public health authorities to rapidly monitor VAD and track vitamin A status in populations.