Evidence for reliability, validity and responsiveness of Turkish Foot and Ankle Ability Measure (FAAM)

被引:22
|
作者
Celik, Derya [1 ]
Malkoc, Melih [2 ]
Martin, RobRoy [3 ]
机构
[1] Istanbul Univ, Div Physiotherapy & Rehabil, Fac Hlth Sci, TR-34740 Istanbul, Turkey
[2] Medipol Univ, Dept Orthoped & Traumatol, Istanbul, Turkey
[3] Duquesne Univ, Pittsburgh, PA 15219 USA
关键词
Cross-cultural adaptation; Ankle and foot; Outcome measurement; Psychometric properties; VERSION; VALIDATION; TRANSLATION; PAIN;
D O I
10.1007/s00296-016-3485-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To translate and culturally adapt the Foot and Ankle Ability Measure (FAAM) into Turkish and assess the psychometric properties of the translated version. The FAAM was translated into Turkish according to Beaton's recommendations and it is called FAAM-T. Ninety-eight patients (39 males, mean +/- SD age 35.0 +/- 14.0 years; range 16-71 years) with different foot and ankle complaints were included, and the score was completed twice by each participant after 7 days of the first assessment to assess test-retest reliability based on the inter-rater correlation coefficient, whereas Cronbach's alpha evaluated internal consistency. External validity was evaluated with correlations between the FAAM-T, Foot Function Index (FFI) and Short Form-36 (SF-36). The distribution of floor and ceiling effects was determined. The test-retest reliability was 0.90 for both FAAM-T subscales. Cronbach's alpha coefficient was 0.95 and 0.91 for FAAM-T activity of daily living (ADL) and FAAM-T Sport subscales, respectively. The FAAM-T ADL and Sport subscales demonstrated very good correlation with the FFI (r = 0.70 and 0.63, respectively). The FAAM-T ADL and Sport subscales had a high level of association with physical functioning and the physical component scale (r = 0.71, r = 0.70 and r = 0.51, r = 0.55, respectively; P = 0.001) of the SF-36. The weakest associations were found between the FAAM-T ADL, FAAM-T Sport subscales and the SF-36 the vitality (r = 0.27, P = 0.008 and r = 0.28, P = 0.01, respectively). The study provides preliminary evidence that the FAAM-T is reliable, valid and responsive outcome measurement of patients with foot and ankle pathologies.
引用
收藏
页码:1469 / 1476
页数:8
相关论文
共 50 条
  • [31] Reliability, validity and responsiveness of the German self-reported foot and ankle score (SEFAS) in patients with foot or ankle surgery
    Dariusch Arbab
    Katharina Kuhlmann
    Christoph Schnurr
    Bertil Bouillon
    Christian Lüring
    Dietmar König
    BMC Musculoskeletal Disorders, 18
  • [32] PROMIS Pain Interference and Physical Function Scores Correlate With the Foot and Ankle Ability Measure (FAAM) in Patients With Hallux Valgus
    Nixon, Devon C.
    McCormick, Jeremy J.
    Johnson, Jeffrey E.
    Klein, Sandra E.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2017, 475 (11) : 2775 - 2780
  • [33] Evidence for reliability, validity and responsiveness of Turkish version of Hip Outcome Score
    Polat, Gokhan
    Celik, Derya
    Cil, Hilal
    Erdil, Mehmet
    Asik, Mehmet
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2017, 51 (04) : 319 - 324
  • [34] Validity, reliability, and responsiveness of the Self-reported Foot and Ankle Score (SEFAS) in forefoot, hindfoot, and ankle disorders
    Coster, Maria C.
    Bremander, Ann
    Rosengren, Bjorn E.
    Magnusson, Hakan
    Carlsson, Ake
    Karlsson, Magnus K.
    ACTA ORTHOPAEDICA, 2014, 85 (02) : 187 - 194
  • [35] Reliability, validity and responsiveness of the German Manchester-Oxford Foot Questionnaire (MOXFQ) in patients with foot or ankle surgery
    Arbab, Dariusch
    Kuhlmann, Katharina
    Ringendahl, Hubert
    Bouillon, Bertil
    Eysel, Peer
    Koenig, Dietmar
    FOOT AND ANKLE SURGERY, 2018, 24 (06) : 481 - 485
  • [36] Reliability, validity and responsiveness of the Spanish Manchester-Oxford Foot Questionnaire (MOXFQ) in patients with foot or ankle surgery
    Gerstner Garces, Juan B.
    Winson, Ian
    Goldhahn, Sabine
    Castro, Michael D.
    Swords, Michael P.
    Grujic, Leslie
    Rammelt, Stefan
    Sands, Andrew K.
    FOOT AND ANKLE SURGERY, 2016, 22 (01) : 59 - 70
  • [37] Validity, Reliability, and Responsiveness of the Korean Version of American Academy of Orthopedic Surgeons Foot and Ankle Questionnaire
    Kim, Ji-Beom
    Kim, Je Kyun
    Seo, Sang Gyo
    Lee, Dong Yeon
    JOURNAL OF FOOT & ANKLE SURGERY, 2015, 54 (01): : 46 - 50
  • [38] Foot and Ankle Ability Measure: cross-cultural translation and validation of the Italian version of the ADL module (FAAM-I/ADL)
    Sartorio, F.
    Vercelli, S.
    Bravini, Elisabetta
    Bargeri, Serena
    Moroso, Michela
    Plebani, G.
    Ferriero, G.
    MEDICINA DEL LAVORO, 2014, 105 (05): : 357 - 365
  • [39] CORR Insights®: PROMIS Pain Interference and Physical Function Scores Correlate With the Foot and Ankle Ability Measure (FAAM) in Patients With Hallux Valgus
    Slullitel, Gaston A.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2017, 475 (11) : 2781 - 2782
  • [40] The Measure of Quality of the Environments' Turkish Validity and Reliability
    Akyurek, Gokcen
    Bumin, Gonca
    OTJR-OCCUPATION PARTICIPATION AND HEALTH, 2019, 39 (04) : 239 - 246