Comparison of Efficacy and Economic Value of Prandilin 25 and Humalog Mix 25 in Patients with Newly Diagnosed Type 2 Diabetes by a Continuous Glucose Monitoring System

被引:3
|
作者
Luo, Yong [1 ]
Wang, Xue-qin [2 ]
Ni, Wen-ji [1 ]
Ding, Bo [1 ]
Xu, Xiang-hong [1 ]
Ye, Lei [3 ]
Ma, Jian-hua [1 ]
Zhu, Jian [1 ]
机构
[1] Nanjing Med Univ, Nanjing Hosp 1, Dept Endocrinol, Nanjing, Jiangsu, Peoples R China
[2] Nantong Univ, Peoples Hosp Nantong City 1, Affiliated Hosp 2, Dept Endocrinol, Nantong, Peoples R China
[3] Natl Heart Ctr Singapore, Natl Heart Res Inst Singapore, Singapore, Singapore
关键词
CGMS; Glycemic variability; Humalog mix 25; Insulin lispro 25; Prandilin; 25; PREMIXED INSULIN ANALOGS; GLYCEMIC VARIABILITY; ADD-ON; MELLITUS; DISEASE; BURDEN; HYPOGLYCEMIA; MECHANISMS; MANAGEMENT; THERAPY;
D O I
10.1007/s13300-018-0502-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
IntroductionTo determine the clinical efficacy and economic value of insulin lispro 25-Prandilin 25 vs. insulin lispro 25-Humalog mix 25 in treatment of newly diagnosed type 2 diabetes mellitus (T2DM) by a continuous glucose monitoring system (CGMS).MethodsThis was a single-center, randomized, case-crossover clinical trial. Participants were randomly allocated to two groups and underwent two kinds of insulin lispro 25 treatment separated by a 1-day washout period. In total, 81 patients with newly diagnosed T2DM with hemoglobin A1c (HbA1c) above 9% were hospitalized and randomly divided to receive Prandilin 25/Humalog mix 25 or Humalog mix 25/Prandilin 25 treatment. All participants were subjected to metformin therapy simultaneously. Glycemic control was reached after 7-8days Prandilin 25 or Humalog mix 25 treatment; each patient received continuous glucose monitoring (CGM) for 5 consecutive days (from day 1 to day 5). On day 3 of CGM performance, Prandilin 25 treatment was switched to Humalog mix 25 treatment at the same dosage or vice versa. Parameters representing glycemic variability (GV) and postprandial glucose excursions, including 24-h mean blood glucose (24hMBG), 24-h standard deviation of blood glucose (24hSDBG), 24-h mean amplitude of glycemic excursion (24hMAGE), large amplitude of glycemic excursion (LAGE), incremental area under the curve (AUC) for different glucose levels, and postmeal relative areas under the CGM curve (AUCpp) for 1-4h of each meal, were calculated for each patient.ResultsNo significant differences were found in the 24hMAGE, 24hMBG, 24hSDBG, LAGE, mean 1-h preprandial blood glucose and the incidence of hypoglycemia between the Prandilin 25 treatment group and Humalog mix 25 treatment group. Similarly, there were no between-treatment differences for AUC and time when blood glucose was below 3.9mmol/l, between 3.9mmol/l and 10.0mmol/l, or above 10.0mmol/l. Further analysis showed the AUCpp for 1-4h of each meal for two kinds of treatments were similar. However, the mean estimated cost of Prandilin 25 was only 85% of Humalog mix 25 in one treatment course.ConclusionPrandilin 25 is non-inferior in clinical efficacy compared with Humalog mix 25. In view of the significant difference in the cost of the two kinds of insulin lispro 25, Prandilin 25 is a much more cost-effective anti-diabetes drug for management of T2DM.Trial RegistrationChinese Clinical Trial Register identifier, ChiCTR1800015829.
引用
收藏
页码:2219 / 2228
页数:10
相关论文
共 50 条
  • [41] A continous glucose monitoring system in type 2 diabetics treated with LisPro mix 25 and premixed insulin 30/70
    Di Bartolo, P
    Scaramuzza, A
    Miselli, V
    Brandolini, S
    Cannatà, F
    DIABETES, 2002, 51 : A95 - A95
  • [42] Efficacy and safety comparison of continuous glucose monitoring and self-monitoring of blood glucose in type 1 diabetes
    Wojciechowski, Piotr
    Rys, Przemyslaw
    Lipowska, Anna
    Gaweska, Magdalena
    Malecki, Maciej T.
    POLSKIE ARCHIWUM MEDYCYNY WEWNETRZNEJ-POLISH ARCHIVES OF INTERNAL MEDICINE, 2011, 121 (10): : 333 - 343
  • [43] Guidance of patients with newly diagnosed type II diabetes on monitoring of blood glucose in Norwegian pharmacies
    Neslein, I. -L.
    Krogstad, T.
    INTERNATIONAL JOURNAL OF CLINICAL PHARMACY, 2019, 41 (01) : 331 - 331
  • [44] Glycemic Outcomes with Early Initiation of Continuous Glucose Monitoring System in Recently Diagnosed Patients with Type 1 Diabetes
    Mulinacci, Giacomo
    Alonso, G. Todd
    Snell-Bergeon, Janet K.
    Shah, Viral N.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2019, 21 (01) : 6 - 10
  • [45] Pre-meal and post-meal use of Humalog® MIX25™ in elderly patients with type 2 diabetes and oral treatment inadequacy with sulfonylureas
    Herz, M
    Sun, B
    DIABETES, 2000, 49 : A111 - A111
  • [46] Effects of Exenatide and Humalog Mix25 on Fat Distribution, Insulin Sensitivity, andβ-Cell Function in Normal BMI Patients with Type 2 Diabetes and Visceral Adiposity
    Wang, Xinlei
    Zhao, Xiaoqin
    Gu, Yunjuan
    Zhu, Xiaohui
    Yin, Tong
    Tang, Zhuqi
    Yuan, Jin
    Chen, Wei
    OuYang, Rong
    Yao, Lili
    Zhang, Rongping
    Yuan, Jie
    Zhou, Ranran
    Sun, Yi
    Cui, Shiwei
    JOURNAL OF DIABETES RESEARCH, 2020, 2020
  • [47] Personal Continuous Glucose Monitoring Use Among Adults with Type 2 Diabetes: Clinical Efficacy and Economic Impacts
    Tamara K. Oser
    Michelle L. Litchman
    Nancy A. Allen
    Bethany M. Kwan
    Lawrence Fisher
    Bonnie T. Jortberg
    William H. Polonsky
    Sean M. Oser
    Current Diabetes Reports, 2021, 21
  • [48] Personal Continuous Glucose Monitoring Use Among Adults with Type 2 Diabetes: Clinical Efficacy and Economic Impacts
    Oser, Tamara K.
    Litchman, Michelle L.
    Allen, Nancy A.
    Kwan, Bethany M.
    Fisher, Lawrence
    Jortberg, Bonnie T.
    Polonsky, William H.
    Oser, Sean M.
    CURRENT DIABETES REPORTS, 2021, 21 (11)
  • [49] Effect of liraglutide vs. NPH in combination with metformin on blood glucose fluctuations assessed using continuous glucose monitoring in patients with newly diagnosed type 2 diabetes
    Ma, Zejun
    Chen, Rui
    Liu, Yan
    Yu, Pei
    Chen, Liming
    INTERNATIONAL JOURNAL OF CLINICAL PHARMACOLOGY AND THERAPEUTICS, 2015, 53 (11) : 933 - 939
  • [50] Comparison of accuracy between flash glucose monitoring and continuous glucose monitoring in patients with type 2 diabetes mellitus undergoing hemodialysis
    Matoba, Kenta
    Hayashi, Akinori
    Shimizu, Naoya
    Moriguchi, Ibuki
    Kobayashi, Naoyuki
    Shichiri, Masayoshi
    JOURNAL OF DIABETES AND ITS COMPLICATIONS, 2020, 34 (11)