Low-cost and automated calibration method for joint offset of industrial robot using single-point constraint

被引:16
|
作者
Liu, Yong [1 ]
Xi, Ning [2 ]
机构
[1] Nanjing Univ Sci & Technol, Sch Comp Sci & Technol, Nanjing, Peoples R China
[2] Michigan State Univ, Dept Elect & Comp Engn, E Lansing, MI 48824 USA
关键词
Robots; Calibration; Precision; Virtual lines-based; Single-point constraint; PSD-based calibration device; TRACKING;
D O I
10.1108/01439911111179093
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Purpose - The industrial robot has high repeatability but low accuracy. With the industrial robot being widely used in complicated tasks, e.g. arc welding, offline programming and surgery, accuracy of the robot is more and more important. Robot calibration is an efficient way to improve the accuracy. Previous methods such as using coordinate measurement machines, laser trackers or cameras are limited by the cost, complex operation or the resolution. The purpose of this paper is to propose an approach and calibration equipment to address these issues. Design/methodology/approach - The proposed method relies mainly upon a laser pointer attached on the end-effector and single position-sensitive devices (PSD) arbitrarily located on the workcell. The automated calibration procedure (about three minutes) involves aiming the laser lines loaded by the robot towards the center of the PSD surface from various robot positions and orientations. The localization is guaranteed by precise PSD feedback servoing control, which means physically the intersections of each pair of laser lines (virtual lines) are on the same point. Based on the untouched single-point constraint, the robot joint offset calibration is implemented. Using the authors' proposed approach, a portable, low-cost, battery-powered, wireless and automated calibration system was implemented. Error analysis was conducted on the system. Findings - The localization error of the developed calibration system is within 2 mu m. The errors in joint space are magnified in PSD plane, and consequently the resolution in the joint space is improved. The standard deviation of the identified parameters was small (10-2), indicating the stability of the calibration method. Both simulation and experimental results verify the feasibility of the proposed method and demonstrate the developed calibration system can identify joint offset with uncalibrated laser tool parameters. Originality/value - The paper shows how a portable calibration system for joint offset of industrial robots was developed and how the goal of fast, automated, low-cost, portable, and high precision calibration methods for joint offset was achieved.
引用
收藏
页码:577 / 584
页数:8
相关论文
共 35 条
  • [21] Low-cost synthesis of single-walled carbon nanohorns using the arc in water method with gas injection
    Sano, N
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2004, 37 (08) : L17 - L20
  • [22] Advanced Signal Processing for Communication Networks and Industrial IoT Machines Using Low-Cost Fixed-Point Digital Signal Processor
    Oyekanlu, Emmanuel
    Scoles, Kevin
    Oladele, Paul O.
    2018 10TH INTERNATIONAL CONFERENCE ON ADVANCED INFOCOMM TECHNOLOGY (ICAIT), 2018, : 93 - 101
  • [23] Enabling low-cost point-of-care ultrasound imaging system using single element transducer and delta configuration actuator
    Xu, Keshuai
    Kim, Younsu
    Boctor, Emad M.
    Zhang, Haichong K.
    MEDICAL IMAGING 2019: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2019, 10951
  • [24] Performance Analysis of Positioning Solution Using Low-Cost Single-Frequency U-Blox Receiver Based on Baseline Length Constraint
    Lu, Liguo
    Ma, Liye
    Wu, Tangting
    Chen, Xiaoyong
    SENSORS, 2019, 19 (19)
  • [25] DETERMINATION OF IRON(III) AND TITANIUM(IV) AS THEIR SOLOCHROME VIOLET RS COMPLEXES BY CONSTANT-CURRENT STRIPPING POTENTIOMETRY .1. AUTOMATED SINGLE-POINT CALIBRATION METHOD FOR IRON(III)
    JAGNER, D
    RENMAN, L
    STEFANSDOTTIR, SH
    ANALYTICA CHIMICA ACTA, 1993, 281 (02) : 305 - 314
  • [26] Removal of gas condensate from industrial wastewater using low-cost adsorbents: Optimization by Box-Behnken design method
    Fouladi, Amin
    Esmaeili, Hossein
    Tamjidi, Sajad
    Foroutan, Rauf
    ENVIRONMENTAL PROGRESS & SUSTAINABLE ENERGY, 2021, 40 (03)
  • [27] A low-cost single-pixel terahertz imaging method using near-field photomodulation and compressed sensing
    She, Rongbin
    Lu, Yuanfu
    Liu, Wenquan
    Zhang, Rui
    Li, Guangyuan
    INFRARED, MILLIMETER-WAVE, AND TERAHERTZ TECHNOLOGIES VI, 2019, 11196
  • [28] Automated superelevation measurement method using a low-cost mobile device an efficient, cost-effective approach toward intelligent horizontal curve safety assessment
    Tsai Y.
    Ai C.
    Ai, Chengbo (chengbo.ai@gatech.edu), 1600, National Research Council (2621): : 62 - 70
  • [29] A Low-Cost Method for Phenotyping Wilting and Recovery of Wheat Leaves under Heat Stress Using Semi-Automated Image Analysis
    Rascio, Agata
    De Santis, Giuditta
    Sorrentino, Giuseppe
    PLANTS-BASEL, 2020, 9 (06): : 1 - 14
  • [30] All-fiber, low-cost single-point and quasi-distributed evanescent field temperature sensors with extended temperature measurement range, based on standard telecommunication graded index fibers
    Kezmah, Marko
    Donlagic, Denis
    APPLIED OPTICS, 2008, 47 (23) : 4212 - 4220