Bias in estimating accuracy of a binary screening test with differential disease verification

被引:12
|
作者
Alonzo, Todd A. [1 ]
Brinton, John T. [2 ]
Ringham, Brandy M. [2 ]
Glueck, Deborah H. [2 ]
机构
[1] Univ So Calif, Div Biostat, Keck Sch Med, Arcadia, CA 91006 USA
[2] Univ Colorado, Dept Biostat, Colorado Sch Publ Hlth, Denver, CO 80202 USA
关键词
bias; predictive values; screening; sensitivity; specificity; FIELD DIGITAL MAMMOGRAPHY; DIAGNOSTIC-TESTS; FILM MAMMOGRAPHY; CANCER-DETECTION; SENSITIVITY; TRIAL; SPECIFICITY; PERFORMANCE; PROGRAM; US;
D O I
10.1002/sim.4232
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Sensitivity, specificity, positive and negative predictive value are typically used to quantify the accuracy of a binary screening test. In some studies, it may not be ethical or feasible to obtain definitive disease ascertainment for all subjects using a gold standard test. When a gold standard test cannot be used, an imperfect reference test that is less than 100 per cent sensitive and specific may be used instead. In breast cancer screening, for example, follow-up for cancer diagnosis is used as an imperfect reference test for women where it is not possible to obtain gold standard results. This incomplete ascertainment of true disease, or differential disease verification, can result in biased estimates of accuracy. In this paper, we derive the apparent accuracy values for studies subject to differential verification. We determine how the bias is affected by the accuracy of the imperfect reference test, the percent who receive the imperfect reference standard test not receiving the gold standard, the prevalence of the disease, and the correlation between the results for the screening test and the imperfect reference test. It is shown that designs with differential disease verification can yield biased estimates of accuracy. Estimates of sensitivity in cancer screening trials may be substantially biased. However, careful design decisions, including selection of the imperfect reference test, can help to minimize bias. A hypothetical breast cancer screening study is used to illustrate the problem. Copyright (C) 2011 John Wiley & Sons, Ltd.
引用
收藏
页码:1852 / 1864
页数:13
相关论文
共 50 条
  • [41] Estimating an ROC curve in the presence of non-ignorable verification bias
    Zhou, Xiao-Hua
    Rodenberg, C.A.
    [J]. Communications in Statistics - Theory and Methods, 27 (03): : 635 - 657
  • [42] Approximate confidence intervals for the likelihood ratios of a binary diagnostic test in the presence of partial disease verification
    Montero-Alonso, M. A.
    Roldan-Nofuentes, J. A.
    [J]. JOURNAL OF BIOPHARMACEUTICAL STATISTICS, 2019, 29 (01) : 56 - 81
  • [43] Estimating an ROC curve in the presence of non-ignorable verification bias
    Zhou, XH
    Rodenberg, CA
    [J]. COMMUNICATIONS IN STATISTICS-THEORY AND METHODS, 1998, 27 (03) : 635 - 657
  • [44] The Impact of Differential Privacy on Recommendation Accuracy and Popularity Bias
    Muellner, Peter
    Lex, Elisabeth
    Schedl, Markus
    Kowald, Dominik
    [J]. ADVANCES IN INFORMATION RETRIEVAL, ECIR 2024, PT IV, 2024, 14611 : 466 - 482
  • [45] Test bias in a cognitive test: differential item functioning in the CASI
    Crane, PK
    van Belle, G
    Larson, EB
    [J]. STATISTICS IN MEDICINE, 2004, 23 (02) : 241 - 256
  • [46] Estimating the accuracy of screening mammography: A meta-analysis
    Mushlin, AI
    Kouides, RM
    Shapiro, DE
    [J]. AMERICAN JOURNAL OF PREVENTIVE MEDICINE, 1998, 14 (02) : 143 - 153
  • [47] Understanding the Direction of Bias in Studies of Diagnostic Test Accuracy
    Kohn, Michael A.
    Carpenter, Christopher R.
    Newman, Thomas B.
    [J]. ACADEMIC EMERGENCY MEDICINE, 2013, 20 (11) : 1194 - 1206
  • [48] PARTIAL VERIFICATION-A COMMON SOURCE OF BIAS IN DIAGNOSTIC ACCURACY STUDIES
    Schmidt, Robert L.
    Cohen, Michael B.
    [J]. ENDOCRINE PRACTICE, 2015, 21 (02) : 211 - 211
  • [49] THE IMPACT OF SELECTION BIAS ON MEASUREMENT OF NONINVASIVE TEST ACCURACY
    SALERNO, DM
    WANG, K
    GOLDENBERG, IF
    VANTASSEL, RA
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1993, 72 (02): : 223 - 225
  • [50] Researchers should be aware of partial verification bias in diagnostic accuracy studies
    Schmidt, Robert L.
    Factor, Rachel E.
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2015, 119 (05): : 593 - 593