In vivo nitric oxide sensor using non-conducting polymer-modified carbon fiber

被引:87
|
作者
Park, JK [1 ]
Tran, PH [1 ]
Chao, JKT [1 ]
Ghodadra, R [1 ]
Rangarajan, R [1 ]
Thakor, NV [1 ]
机构
[1] Johns Hopkins Univ, Sch Med, Dept Biomed Engn, Baltimore, MD 21205 USA
来源
BIOSENSORS & BIOELECTRONICS | 1998年 / 13卷 / 11期
关键词
nitric oxide; in vivo sensor; carbon fiber; Nafion; m-phenylenediamine; resorcinol;
D O I
10.1016/S0956-5663(98)00078-5
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Nitric oxide (NO) is emerging as a very important and ubiquitous gaseous messenger in the body. The response characteristics of NO sensors made of non-conducting polymer modified carbon fiber electrodes are investigated to determine their selectivity, sensitivity, and stability for in vivo use. A composite polymer, comprising Nafion, m-phenylenediamine, and resorcinol, showed the best selectivity and stability to amperometric NO detection. The non-conducting, self-limiting polymer film protects the electrode from interference and fouling by other biochemicals. Although the relative sensitivity to NO of the modified sensor is lower than that of the unmodified carbon fiber electrodes (less than 6%), the composite polymer electrode showed high selectivity against ascorbic acid ( > 2000:1), nitrite ( > 600:1), and dopamine ( > 200:1). The stability of the NO sensor was maintained for at least 1 week. The NO sensitivity after in vivo experiments (n = 8) is 88.1 +/- 5.6% of initial sensitivity data obtained before in vivo experiments. Preliminary in vivo experiments done with this electrode are shown to capture elevated NO levels in brain following an ischemic injury. (C) 1998 Elsevier Science S.A. All rights reserved.
引用
收藏
页码:1187 / 1195
页数:9
相关论文
共 50 条
  • [41] Nitric oxide sensor based on carbon fiber covered with nickel porphyrin layer deposited using optimized electropolymerization procedure
    Hrbac, Jan
    Gregor, Cenek
    Machova, Marketa
    Kralova, Jana
    Bystron, Tomas
    Ciz, Milan
    Lojek, Antonin
    BIOELECTROCHEMISTRY, 2007, 71 (01) : 46 - 53
  • [42] [Os(bpy)(2)(PVI)(10)Cl]Cl polymer-modified carbon fiber electrodes for the electrocatalytic oxidation of NADH
    Ju, HX
    Leech, D
    ANALYTICA CHIMICA ACTA, 1997, 345 (1-3) : 51 - 58
  • [43] The Electrochemical Resolution of Ciprofloxacin, Riboflavin and Estriol Using Anionic Surfactant and Polymer-Modified Carbon Paste Electrode
    Pushpanjali, Pemmatte A.
    Manjunatha, Jamballi G.
    Shreenivas, Mellekatte T.
    CHEMISTRYSELECT, 2019, 4 (46): : 13427 - 13433
  • [44] A novel amperometric nitric oxide sensor based on polythionine/nafion modified glassy carbon electrode
    Chen, XX
    Wang, F
    Xu, YX
    Hu, SS
    CHINESE CHEMICAL LETTERS, 2006, 17 (04) : 496 - 498
  • [46] The Effect of Low Weight Percent Multiwalled Carbon Nanotubes on the Dielectric Properties of Non-Conducting Polymer/Ceramic Nanocomposites for Energy Storage Materials
    Khattak, Noor Saeed
    Khan, Mohammad Saleem
    Shah, Luqman Ali
    Farooq, Muhammad
    Khan, Abdullah
    Ahmad, Safeer
    Jan, Saeed Ullah
    Rehman, Noor
    ZEITSCHRIFT FUR PHYSIKALISCHE CHEMIE-INTERNATIONAL JOURNAL OF RESEARCH IN PHYSICAL CHEMISTRY & CHEMICAL PHYSICS, 2020, 234 (01): : 11 - 26
  • [47] In vivo imaging of hepatocellular nitric oxide using a hepatocyte-targeting fluorescent sensor
    Zhang, Peisheng
    Tian, Yong
    Liu, Hui
    Ren, Junyu
    Wang, Hong
    Zeng, Rongjin
    Long, Yunfei
    Chen, Jian
    CHEMICAL COMMUNICATIONS, 2018, 54 (52) : 7231 - 7234
  • [48] Minimally invasive current-controlled electrical stimulation system for bacteria using highly capacitive conducting polymer-modified electrodes
    Makino D.
    Ueki A.
    Matsumoto H.
    Nagamine K.
    Bioelectrochemistry, 2023, 149
  • [49] Reagentless Affimer- and antibody-based impedimetric biosensors for CEA-detection using a novel non-conducting polymer
    Shamsuddin, Shazana Hilda
    Gibson, Timothy D.
    Tomlinson, Darren C.
    McPherson, Michael J.
    Jayne, David G.
    Millner, Paul A.
    BIOSENSORS & BIOELECTRONICS, 2021, 178
  • [50] A sensor for acetaminophen in a blood medium using a Cu(II)-conducting polymer complex modified electrode
    Boopathi, M
    Won, MS
    Shim, YB
    ANALYTICA CHIMICA ACTA, 2004, 512 (02) : 191 - 197