Evaluating and improving the performance of thin film force sensors within body and device interfaces

被引:15
|
作者
Likitlersuang, Jirapat [1 ,2 ]
Leineweber, Matthew J. [2 ]
Andrysek, Jan [1 ,2 ]
机构
[1] Univ Toronto, Inst Biomat & Biomed Engn, Toronto, ON, Canada
[2] Holland Bloorview Kids Rehabil Hosp, Bloorview Res Inst, Toronto, ON, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Accuracy; Calibration; Force sensors; Interface pressure; Pressure measurement; PRESSURE; GLIDESCOPE(R); LARYNGOSCOPY; COMPRESSION; SYSTEM;
D O I
10.1016/j.medengphy.2017.06.017
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Thin film force sensors are commonly used within biomechanical systems, and at the interface of the human body and medical and non-medical devices. However, limited information is available about their performance in such applications. The aims of this study were to evaluate and determine ways to improve the performance of thin film (FlexiForce) sensors at the body/device interface. Using a custom apparatus designed to load the sensors under simulated body/device conditions, two aspects were explored relating to sensor calibration and application. The findings revealed accuracy errors of 23.3 +/- 17.6% for force measurements at the body/device interface with conventional techniques of sensor calibration and application. Applying a thin rigid disc between the sensor and human body and calibrating the sensor using compliant surfaces was found to substantially reduce measurement errors to 2.9 +/- 2.0%. The use of alternative calibration and application procedures is recommended to gain acceptable measurement performance from thin film force sensors in body/device applications. (C) 2017 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:206 / 211
页数:6
相关论文
共 50 条
  • [21] Micromachined force sensors using thin film nickel-chromium piezoresistors
    Nadvi, Gaviraj S.
    Butler, Donald P.
    Celik-Butler, Zeynep
    Goenenli, Ismail Erkin
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2012, 22 (06)
  • [22] Microstructure and device performance of thin film light emitting polymers
    Yimsiri, Piyachat
    Mackley, Malcolm R.
    THIN SOLID FILMS, 2007, 515 (7-8) : 3787 - 3796
  • [23] Stimulus Performance of Thin-film Biological Stimulation Device
    Tomioka, Keisuke
    Miyake, Kohei
    Matsuda, Tokiyoshi
    Kimura, Mutsumi
    2017 24TH INTERNATIONAL WORKSHOP ON ACTIVE-MATRIX FLATPANEL DISPLAYS AND DEVICES (AM-FPD), 2017, : 187 - 189
  • [24] THIN-FILM ELECTROLUMINESCENT DISPLAYS - DEVICE CHARACTERISTICS AND PERFORMANCE
    ALT, PM
    PROCEEDINGS OF THE SID, 1984, 25 (02): : 123 - 146
  • [25] Fabrication of ZnO Thin Film Sensor for MIS Flexible Force Feedback Device
    Chan, Shih-Chi
    Lin, David T. W.
    Liu, Kai-Che
    Ou, Jing-Jim
    Verma, Ashwin
    2016 IEEE 11TH ANNUAL INTERNATIONAL CONFERENCE ON NANO/MICRO ENGINEERED AND MOLECULAR SYSTEMS (NEMS), 2016,
  • [26] Improving Contact Interfaces in Fully Printed Carbon Nanotube Thin-Film Transistors
    Cao, Changyong
    Andrews, Joseph B.
    Kumar, Abhinay
    Franklin, Aaron D.
    ACS NANO, 2016, 10 (05) : 5221 - 5229
  • [27] High performance surface inspection method for thin-film sensors
    Wieser, Volkmar
    Larndorfer, Stefan
    Moser, Bernhard
    MACHINE VISION APPLICATIONS IN INDUSTRIAL INSPECTION XV, 2007, 6503
  • [28] Ultrasonic performance of the PVDF thin film sensors under thermal fatigue
    Rathod, Vivek T.
    Mahapatra, D. Roy
    Jain, Anjana
    Gayathri, A.
    BEHAVIOR AND MECHANICS OF MULTIFUNCTIONAL MATERIALS AND COMPOSITES 2012, 2012, 8342
  • [29] Numerical analysis of the design parameters on the performance of thin film temperature sensors
    Jia, Yi
    Araya, Guillermo
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2007, 18 (07) : 2268 - 2274
  • [30] PERFORMANCE OF THIN-FILM HUMIDITY SENSORS IN POULTRY AND SWINE ENVIRONMENTS
    HAO, H
    LEONARD, JJ
    CANADIAN AGRICULTURAL ENGINEERING, 1994, 36 (04): : 273 - 277