Preliminary evaluation of a monolithic detector module for integrated PET/MRI scanner with high spatial resolution

被引:21
|
作者
Pani, R. [1 ]
Gonzalez, A. J. [2 ]
Bettiol, M. [1 ,3 ]
Fabbri, A. [1 ]
Cinti, M. N. [1 ]
Preziosi, E. [1 ,4 ]
Borrazzo, C. [1 ,3 ]
Conde, P. [2 ]
Pellegrini, R. [1 ]
Di Castro, E. [5 ]
Majewski, S. [6 ]
机构
[1] Univ Roma La Sapienza, Dept Mol Med, I-00185 Rome, Italy
[2] CSIC, I3M, Valencia 46022, Spain
[3] Univ Roma La Sapienza, Postgrad Sch Med Phys, I-00185 Rome, Italy
[4] Univ Roma La Sapienza, SAIMLAL Dept, Doctorate Sch Biol & Mol Med, Morphofunct Sci Biophys, I-00185 Rome, Italy
[5] Univ Roma La Sapienza, Dept Radiol Sci Oncol & Pathol, I-00185 Rome, Italy
[6] W Virginia Univ, Dept Radiol, Ctr Adv Imaging, Morgantown, WV 26506 USA
来源
关键词
Gamma camera; SPECT; PET PET/CT; coronary CT angiography (CTA); Medical-image reconstruction methods and algorithms; computer-aided software; Multi-modality systems;
D O I
10.1088/1748-0221/10/06/C06006
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The proposal of Mindview European Project concerns with the development of a very high resolution and high efficiency brain dedicated PET scanner simultaneously working with a Magnetic Resonance scanner, that expects to visualize neurotransmitter pathways and their disruptions in the quest to better diagnose schizophrenia. On behalf of this project, we propose a low cost PET module for the first prototype, based on monolithic crystals, suitable to be integrated with a head Radio Frequency (RF) coil. The aim of the suggested module is to achieve high performances in terms of efficiency, planar spatial resolution (expected about 1 mm) and discrimination of gamma Depth Of Interaction (DOI) in order to reduce the parallax error. Our preliminary results are very promising: a DOI resolution of about 3 mm, a spatial resolution ranging from about 1 to 1.5 mm and a good position linearity.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] A High Resolution, Monolithic Crystal, PET/MRI Detector with DOI Positioning Capability
    Li, Xiaoli
    Lockhart, Cate
    Lewellen, Tom K.
    Miyaoka, Robert S.
    [J]. 2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 2287 - +
  • [2] Preliminary performance evaluation of a high resolution small animal PET scanner with monolithic crystals and depth-of-interaction encoding
    Balcerzyk, Marcin
    Kontaxakis, George
    Delgado, Mercedes
    Garcia, Luis
    Benlloch, Jose M.
    Pozo, Miguel A.
    [J]. 8TH IEEE INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOENGINEERING, VOLS 1 AND 2, 2008, : 944 - +
  • [3] Design of a High Resolution, Monolithic Crystal, PET/MRI Detector with DOI Positioning Capability
    Miyaoka, Robert S.
    Li, Xiaoli
    Lockhart, Cate
    Lewellen, Tom K.
    [J]. 2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 3961 - +
  • [4] Improved Spatial Resolution and Resolution Uniformity of Monolithic PET Detector by Optimization of Photon detector Arrangement
    Lyu, Zhenlei
    Fan, Peng
    Xu, Tianpeng
    Wang, Rui
    Liu, Yaqiang
    Wang, Shi
    Wu, Zhaoxia
    Ma, Tianyu
    [J]. 2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [5] Optical simulation study on the spatial resolution of a thick monolithic PET detector
    Stockhoff, Mariele
    Van Holen, Roel
    Vandenberghe, Stefaan
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (19):
  • [6] Evaluation of PET Spatial Resolution on integrated PET/MR
    Xie, Feng
    Zhuang, Jingwen
    Wu, Tianqi
    Bai, Mei
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2016, 57
  • [7] Evaluation Detector Module of the miniPET-3 Small Animal PET Scanner
    Imrek, J.
    Hegyesi, Gy.
    Kalinka, G.
    Kiraly, B.
    Molnar, J.
    Nagy, F.
    Valastyan, I.
    Balkay, L.
    Szabo, Zs.
    [J]. 2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 3790 - 3793
  • [8] Preliminary Studies of J-PET Detector Spatial Resolution
    Pawlik-Niedzwiecka, M.
    Niedzwiecki, S.
    Alfs, D.
    Bialas, P.
    Curceanu, C.
    Czerwinski, E.
    Dulski, K.
    Gajos, A.
    Glowacz, B.
    Gorgol, M.
    Hiesmayr, B. C.
    Jasinska, B.
    Kisielewska, D.
    Korcyl, G.
    Kowalski, P.
    Kozik, T.
    Krawczyk, N.
    Krzemien, W.
    Kubicz, E.
    Mohammed, M.
    Palka, M.
    Raczynski, L.
    Raj, J.
    Rudy, Z.
    Shivani
    Silarski, M.
    Skurzok, M.
    Sharma, N. G.
    Sharma, S.
    Shopa, R. Y.
    Strzelecki, A.
    Wieczorek, A.
    Wislicki, W.
    Zgardzinska, B.
    Zielinski, M.
    Moskal, P.
    [J]. ACTA PHYSICA POLONICA A, 2017, 132 (05) : 1645 - 1648
  • [9] MRI Compatible Preclinical PET Scanner With High Sensitivity and Resolution
    Rissi, M.
    Bolle, E.
    Boeck, M.
    Buskenes, J.
    Dorholt, O.
    Hines, K.
    Rhoehne, O.
    Stapnes, S.
    Bjaalie, J. G.
    Skretting, A.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 : S220 - S220
  • [10] Integrated optical and nuclear simulation of a monolithic LYSO:Ce based PET detector module
    Jatekos, B.
    Patay, G.
    Lorincz, E.
    Erdei, G.
    [J]. JOURNAL OF INSTRUMENTATION, 2017, 12