Influence of Arc Discharge on Contact Erosion and Contact Resistance in a Hybrid DC Switch

被引:0
|
作者
Ou, Chomrong [1 ]
Nakayama, Ryo [1 ]
Zen, Shungo [1 ]
Takeuchi, Nozomi [1 ]
Yasuoka, Koichi [1 ]
机构
[1] Tokyo Inst Technol, Fac Engn, Dept Elect & Elect Engn, Tokyo, Japan
关键词
Hybrid DC switch; arc discharge; molten bridge; contact erosion and contact resistance; DURATION;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Contact erosion due to an arc discharge is a critical problem particularly for a DC switch or a DC circuit breaker. Longer duration arc causes higher degradation of their reliability and lifetime. A hybrid DC switch composed of mechanical switch and semiconductor device decreases the duration of the arc, comparing to conventional mechanical switch. The aim of this work is to examine the influence of arc-discharge duration on the electrode erosion and resistance in opening contacts of hybrid DC switch. In experiment, DC power source and SiC-MOSFET device were connected in parallel with the contact pair. The main current flowing through the contacts varied from 200 to 800 A. When the contacts started separating and the SiC-MOSFET turned on simultaneously, the arc occurred between the contacts and commutated the circuit current from the contacts to the SiC-MOSFET until it extinguished. The arc voltage and current waveforms together with the contact resistance were measured. The contact surface erosion was observed by a scanning electron microscope.
引用
收藏
页码:184 / 188
页数:5
相关论文
共 50 条
  • [21] CONTACT RESISTANCE AND ARC EROSION OF W-AG AND WC-AG
    LINDMAYER, M
    ROTH, M
    IEEE TRANSACTIONS ON COMPONENTS HYBRIDS AND MANUFACTURING TECHNOLOGY, 1979, 2 (01): : 70 - 75
  • [22] Contact Resistance and Arc Erosion of Tungsten-copper Contacts in Direct Currents
    Ma Douqin
    Xie Jingpei
    Li Jiwen
    Wang Aiqin
    Wang Wenyan
    JOURNAL OF WUHAN UNIVERSITY OF TECHNOLOGY-MATERIALS SCIENCE EDITION, 2017, 32 (04): : 816 - 822
  • [23] Contact resistance and arc erosion of tungsten-copper contacts in direct currents
    Douqin Ma
    Jingpei Xie
    Jiwen Li
    Aiqin Wang
    Wenyan Wang
    Journal of Wuhan University of Technology-Mater. Sci. Ed., 2017, 32 : 816 - 822
  • [24] Contact Resistance and Arc Erosion of Tungsten-copper Contacts in Direct Currents
    马窦琴
    XIE Jingpei
    LI Jiwen
    WANG Aiqin
    WANG Wenyan
    JournalofWuhanUniversityofTechnology(MaterialsScience), 2017, 32 (04) : 816 - 822
  • [25] A new circuit and operation for non-arc metal contact dc switch 2021
    Yamaguchi, Satarou
    Yoshimura, Koji
    Kato, Kento
    2021 IEEE FOURTH INTERNATIONAL CONFERENCE ON DC MICROGRIDS (ICDCM), 2021,
  • [26] The Influence of Mechanical Alloying and Plastic Consolidation on the Resistance to Arc Erosion of the Ag-Re Composite Contact Material
    Kolacz, Dariusz
    Ksiezarek, Stanislaw
    Borkowski, Piotr
    Karwan-Baczewska, Joanna
    Lis, Marcin
    Kaminska, Malgorzata
    Juszczyk, Barbara
    Kulasa, Joanna
    Kowalski, Aleksander
    Wierzbicki, Lukasz
    Marszowski, Krzysztof
    Jablonski, Mariusz
    MATERIALS, 2021, 14 (12)
  • [27] Influence of electrical contact system design principles on the erosion of electrical switch gears
    Weis, Martin
    VDE Fachberichte, 2017, 73 : 123 - 128
  • [28] Investigation of the Plasma of a DC hybrid-switch model at beginning of contact separation
    Gonzalez, Diego
    Methling, Ralf
    Gortschakow, Sergey
    Koepf, Hendrik
    Steegmueller, Peter
    Holbe, Stefan
    2022 IEEE 67TH HOLM CONFERENCE ON ELECTRICAL CONTACTS (HLM), 2022, : 206 - 211
  • [29] Influence of operation numbers on arc erosion of Ag/CuO electrical contact material
    Qiong Wu
    Guofu Xu
    Meng Yuan
    Chunping Wu
    Journal of Materials Science: Materials in Electronics, 2020, 31 : 2497 - 2513
  • [30] Influence of operation numbers on arc erosion of Ag/CuO electrical contact material
    Wu, Qiong
    Xu, Guofu
    Yuan, Meng
    Wu, Chunping
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN ELECTRONICS, 2020, 31 (03) : 2497 - 2513