Ion storage dosimetry

被引:9
|
作者
Mathur, VK [1 ]
机构
[1] USN, Ctr Surface Warfare, Carderock Div, Radiat Technol Off, Bethesda, MD 20817 USA
关键词
Data storage equipment - Ionization chambers - MOSFET devices - Optimization - Radiation;
D O I
10.1016/S0168-583X(01)00714-5
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The availability of a reliable, accurate and cost-effective real-time personnel dosimetry system is fascinating to radiation workers. Electronic dosimeters are contemplated to meet this demand of active dosimetry. The development of direct ion storage (DIS) dosimeters. a member of the electronic dosimeter family, for personnel dosimetry is also an attempt in this direction. DIS dosimeter is a hybrid of the well-established technology of ion chambers and the latest advances in data storage using metal oxide semiconductor field effect transistor (MOSFET) analog memory device. This dosimeter is capable of monitoring legal occupational radiation doses of gamma, X-rays, beta and neutron radiation. Similar to an ion chamber. the performance of the dosimeter for a particular application can be optimized through the selection of appropriate wall materials. The use of the floating gate of a MOSFET as one of the electrodes of the ion chamber allows the miniaturization of the device to the size of a dosimetry badge and avoids the use of power supplies during dose accumulation. The concept of the device. underlying physics and the design of the DIS dosimeter are discussed. The results of preliminary testing of the device are also provided. Published by Elsevier Science B.V.
引用
收藏
页码:190 / 206
页数:17
相关论文
共 50 条
  • [1] Ion storage dosimetry (vol 184, pg 190, 2001)
    Mathur, VK
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2002, 187 (04): : 579 - 579
  • [2] Evaluation of a Direct-Ion Storage Dosimeter in Personnel Radiation Dosimetry
    Quails, N.
    Zhang, J.
    Yang, X.
    Hintenlang, D.
    MEDICAL PHYSICS, 2022, 49 (06) : E653 - E653
  • [3] TESTING THE DIRECT ION STORAGE DOSEMETER FOR PERSONAL DOSIMETRY IN A NUCLEAR RESEARCH CENTRE AND A HOSPITAL
    Vanhavere, F.
    Covens, P.
    RADIATION PROTECTION DOSIMETRY, 2010, 138 (04) : 334 - 339
  • [4] Comparison of Dosimetry from Direct Ion Storage (DIS) and Optically Stimulated Luminescence (OSL) Dosimeters
    Smith, Mark
    Myers, Erin
    JOURNAL OF NUCLEAR MEDICINE, 2023, 64
  • [5] Comparison between direct ion storage and thermoluminescence dosimetry individual monitoring systems, and internet reporting
    Kiuru, A
    Kahilainen, J
    Hyvönen, H
    Vartiainen, E
    RADIATION PROTECTION DOSIMETRY, 2001, 96 (1-3) : 231 - 233
  • [6] Direct ion storage dosimetry systems for photon, beta and neutron radiation with instant readout capabilities
    Wernli, C
    Kahilainen, J
    RADIATION PROTECTION DOSIMETRY, 2001, 96 (1-3) : 255 - 259
  • [7] Dosimetry for ion beam radiotherapy
    Karger, Christian P.
    Jaekel, Oliver
    Palmans, Hugo
    Kanai, Tatsuaki
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (21): : R193 - R234
  • [8] Ion-kill dosimetry
    Katz, R
    Cucinotta, FA
    Fromm, M
    Chambaudet, A
    PHYSICA MEDICA, 2001, 17 : 164 - 165
  • [9] DOSIMETRY MEASUREMENT IN ION IMPLANTERS
    JAMBA, DM
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1981, 189 (01): : 253 - 263
  • [10] Gafchromic® EBT films for ion dosimetry
    Martisikova, M.
    Jaekel, O.
    RADIATION MEASUREMENTS, 2010, 45 (10) : 1268 - 1270