Analysis of emerging contaminants in water and solid samples using high resolution mass spectrometry with a Q Exactive orbital ion trap and estrogenic activity with YES-assay

被引:59
|
作者
Comtois-Marotte, Simon [1 ]
Chappuis, Thomas [1 ]
Sung Vo Duy [1 ]
Gilbert, Nicolas [2 ]
Lajeunesse, Andre [2 ]
Taktek, Salma [3 ]
Desrosiers, Melanie [3 ]
Veilleux, Eloise [3 ]
Sauve, Sebastien [1 ]
机构
[1] Univ Montreal, Dept Chem, Montreal, PQ, Canada
[2] Univ Quebec Trois Rivieres, Dept Chim Biochim & Phys, Trois Rivieres, PQ, Canada
[3] Minist Dev Durable Environm & Lutte Changements C, Ctr Expertise Anal Environm Quebec, Quebec City, PQ, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Emerging contaminants; High-resolution mass spectrometry; Multi-residue analysis; Liquid chromatography; YES-assay; SUSPENDED PARTICULATE MATTER; PERFORMANCE LIQUID-CHROMATOGRAPHY; WASTE-WATER; PHASE EXTRACTION; TREATMENT PLANTS; ILLICIT DRUGS; PHARMACEUTICAL COMPOUNDS; QUANTITATIVE PERFORMANCE; ORGANIC CONTAMINANTS; ASSISTED EXTRACTION;
D O I
10.1016/j.chemosphere.2016.09.077
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Trace emerging contaminants (ECs) occur in both waste and surface waters that are rich in particulates that have been found to sorb several organic contaminants. An analytical method based on off-line solid phase extraction (SPE) followed by liquid chromatography-mass spectrometry (LC-MS) analysis was developed for the detection and quantification of 31 ECs from surface water, wastewater, suspended particulate matter (SPM) as well as sediments. Lyophilized sediments and air-dried SPM were subjected to ultrasonic extraction. Water samples and extracts were then concentrated and cleaned-up by off-line SPE. Quantification was realized using a Q Exactive mass spectrometer in both full scan (FS) and MS2 modes. These two modes were optimized and compared to determine which one was the most suitable for each matrix studied. Yeast estrogen screen assay (YES-assay) adapted from the direct measurement of estrogenic activity without sample extraction was tested on filtered wastewater samples. An endocrine disrupting effect was detected in all effluent samples analyzed with estradiol equivalent concentrations ranging from 4.4 to 720 ng eq E2 L-1 for the WWTP-1 and 6.5-42 ng eq E2 L-1 for the WWTP-2. The analytical methods were also applied on six samples of surface water, the corresponding SPM, the sediments and thirty-nine effluent samples from two wastewater treatment plants (WWTPs) sampled over a period of five months (February to June 2014). (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:400 / 411
页数:12
相关论文
共 49 条
  • [1] Analysis of estrogenic contaminants in river water using liquid chromatography coupled to ion trap based mass spectrometry
    Benijts, T
    Dams, R
    Günther, W
    Lambert, W
    De Leenheer, A
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (14) : 1358 - 1364
  • [2] Emerging micropollutants in environment: Analysis of water samples by high resolution mass spectrometry
    Chachignon, Mathilde
    Cocardon, Emilie
    Denieul, Marie-Pierre
    Ingrand, Valerie
    Leroy, Gaela
    Meheut, Gaelle
    Tondelier, Christophe
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2018, 255
  • [3] Exploring the Behaviour of Emerging Contaminants in the Water Cycle using the Capabilities of High Resolution Mass Spectrometry
    Hollender, Juliane
    Bourgin, Marc
    Fenner, Kathrin B.
    Longree, Philipp
    McArdell, Christa S.
    Moschet, Christoph
    Ruff, Matthias
    Schymanski, Emma L.
    Singer, Heinz P.
    CHIMIA, 2014, 68 (11) : 793 - 798
  • [4] Determination of steroid hormone residues in farmed fish using high-resolution orbital ion trap mass spectrometry
    Pan, Xiao-Dong
    Han, Jian-Long
    ANALYTICAL METHODS, 2022, 14 (41) : 4146 - 4152
  • [5] Ion Mobility-High-Resolution Mass Spectrometry (IM-HRMS) for the Analysis of Contaminants of Emerging Concern (CECs): Database Compilation and Application to Urine Samples
    Belova, Lidia
    Caballero-Casero, Noelia
    van Nuijs, Alexander L. N.
    Covaci, Adrian
    ANALYTICAL CHEMISTRY, 2021, 93 (16) : 6428 - 6436
  • [6] Determination of fipronil and its metabolites in egg samples by UHPLC coupled with Q-Exactive high resolution mass spectrometry after magnetic solid-phase extraction
    Zhao, Yan
    Bai, Xiao-Lin
    Liu, Yi-Ming
    Liao, Xun
    MICROCHEMICAL JOURNAL, 2021, 169
  • [7] Determination of environmental estrogens and bisphenol A in water samples by ultra-high performance liquid chromatography coupled to Q-Exactive high resolution mass spectrometry after magnetic solid-phase extraction
    Zhao, Yan
    Bai, Xiao-Lin
    Song, Tao
    Zhang, Guo-Lin
    Yuan, Yun-Cong
    Liu, Yi-Ming
    Liao, Xun
    MICROCHEMICAL JOURNAL, 2019, 151
  • [8] Analysis of steroids in environmental water samples using solid-phase extraction and ion-trap gas chromatography-mass spectrometry and gas chromatography-tandem mass spectrometry
    Kelly, C
    JOURNAL OF CHROMATOGRAPHY A, 2000, 872 (1-2) : 309 - 314
  • [9] Multi-residue analysis of pesticide residues and polychlorinated biphenyls in fruit and vegetables using orbital ion trap high-resolution accurate mass spectrometry
    Jim Garvey
    Tony Walsh
    Elaine Devaney
    Teresa King
    Ross Kilduff
    Analytical and Bioanalytical Chemistry, 2020, 412 : 7113 - 7121
  • [10] Multi-residue analysis of pesticide residues and polychlorinated biphenyls in fruit and vegetables using orbital ion trap high-resolution accurate mass spectrometry
    Garvey, Jim
    Walsh, Tony
    Devaney, Elaine
    King, Teresa
    Kilduff, Ross
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2020, 412 (26) : 7113 - 7121