A data readout system with high-speed serial data link for balloonborne x-ray detectors

被引:0
|
作者
Nomachi, M [1 ]
Ishii, S [1 ]
Kuroda, Y [1 ]
Nakamura, H [1 ]
Sugimoto, T [1 ]
Takahashi, T [1 ]
机构
[1] Osaka Univ, Grad Sch Sci, Toyonaka, Osaka 5600043, Japan
关键词
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Data size of recent balloonborne detector is growing. High speed data readout is one of the key technologies for those detectors. A parallel data bus has been used for sending data with high speed. However, it causes problems in noise, mechanic:l size and power consumption. We apply the serial data link for our apparatus as a replacement of the parallel data link to solve those problems. We designed the hardware and firmware based on the SpaceWire protocol. Because of simple and flexible routing protocol of SpaceWire, the system was compact and has very high modularity. The protocol is implemented on Altera's FPGAs, APEX20KE and Cyclone. The speed of the serial data link was 48 similar to 53 Mbps. The maximum data rate to the computer was 4.5MB/s.
引用
下载
收藏
页码:1478 / 1482
页数:5
相关论文
共 50 条
  • [1] High speed readout of microgap X-ray detectors
    Durst, Roger D.
    Diawara, Yacouba
    Benning, Matt
    Becker, Bruce
    Sedov, Vladisov
    Wachter, Greg
    Kocsis, Menhard
    Herve, Christian
    Farajado, Pablo
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2008, 64 : C161 - C162
  • [2] A novel receiver in high-speed serial data link
    Li, HL
    Mao, C
    Xiong, J
    Men, CY
    He, LN
    Yan, XL
    2003 5TH INTERNATIONAL CONFERENCE ON ASIC, VOLS 1 AND 2, PROCEEDINGS, 2003, : 623 - 626
  • [3] High-resolution X-ray detectors with high-speed SQUID readout of superconducting tunnel junctions
    Frank, M
    Mears, CA
    Labov, SE
    Azgui, F
    Lindeman, MA
    Hiller, LJ
    Netel, H
    Barfknecht, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 370 (01): : 41 - 43
  • [4] HIGH-SPEED COLLECTION AND PRECISION REDUCTION OF X-RAY DATA
    PARRISH, W
    HUANG, TC
    AYERS, GL
    ACTA CRYSTALLOGRAPHICA SECTION A, 1978, 34 : S338 - S338
  • [5] EVALUATION OF A HIGH-SPEED SERIAL LINK FOR MARINE DATA ACQUISITION
    CRANFORD, JC
    ORSI, TH
    OCEAN ENGINEERING, 1992, 19 (05) : 469 - 477
  • [6] USB 2.0 data acquisition system for high-speed X-ray elemental mapping
    Alberti, R.
    Guazzoni, C.
    Klatka, T.
    JOURNAL OF INSTRUMENTATION, 2008, 3
  • [7] Hybrid CMOS detectors for high-speed X-ray imaging
    Porter, J. L.
    Looker, Q.
    Claus, L.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2023, 94 (06):
  • [8] A MICROPROGRAMMABLE HIGH-SPEED DATA-COLLECTION SYSTEM FOR POSITION-SENSITIVE X-RAY-DETECTORS
    HASHIZUME, H
    IITAKA, Y
    OGAWA, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 225 (02): : 335 - 346
  • [9] High-speed readout system of X-ray CMOS image sensor for time domain astronomy
    Ogino, Naoki
    Arimoto, Makoto
    Sawano, Tatsuya
    Yonetoku, Daisuke
    Shen, Hsien-chieh
    Sakamoto, Takanori
    Hiraga, Junko S.
    Yatsu, Yoichi
    Mihara, Tatehiro
    JOURNAL OF INSTRUMENTATION, 2024, 19 (01)
  • [10] High-speed on-board data processing for X-ray CCD camera
    Anabuki, N
    Ozaki, M
    Kawasaki, M
    Ogawa, M
    Dotani, T
    X-RAY AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY XII, 2002, 4497 : 158 - 165