Ultrasound pre-clinical Platform for Diagnosis and Targeted Therapy
被引:1
|
作者:
论文数: 引用数:
h-index:
机构:
Certon, D.
[1
]
Legros, L.
论文数: 0引用数: 0
h-index: 0
机构:
Vermon, F-37038 Tours 1, FranceUniv Tours, GREMAN, UMR CNRS 7347, F-37032 Tours, France
Legros, L.
[2
]
Gross, D.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Tours, GREMAN, UMR CNRS 7347, F-37032 Tours, FranceUniv Tours, GREMAN, UMR CNRS 7347, F-37032 Tours, France
Gross, D.
[1
]
Vince, Ph.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Tours, CETU Althais Technol, F-37032 Tours, FranceUniv Tours, GREMAN, UMR CNRS 7347, F-37032 Tours, France
Vince, Ph.
[3
]
Gens, F.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Tours, CETU Althais Technol, F-37032 Tours, FranceUniv Tours, GREMAN, UMR CNRS 7347, F-37032 Tours, France
Gens, F.
[3
]
Gregoire, J. M.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Tours, INSERM, U930, F-37032 Tours, FranceUniv Tours, GREMAN, UMR CNRS 7347, F-37032 Tours, France
Gregoire, J. M.
[4
]
Coutier, C.
论文数: 0引用数: 0
h-index: 0
机构:
CEA LETI, Lab Composants Micro Capteurs, F-38054 Grenoble 9, FranceUniv Tours, GREMAN, UMR CNRS 7347, F-37032 Tours, France
Coutier, C.
[5
]
Novell, A.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Tours, INSERM, U930, F-37032 Tours, FranceUniv Tours, GREMAN, UMR CNRS 7347, F-37032 Tours, France
Novell, A.
[4
]
论文数: 引用数:
h-index:
机构:
Bouakaz, A.
[4
]
机构:
[1] Univ Tours, GREMAN, UMR CNRS 7347, F-37032 Tours, France
[2] Vermon, F-37038 Tours 1, France
[3] Univ Tours, CETU Althais Technol, F-37032 Tours, France
[4] Univ Tours, INSERM, U930, F-37032 Tours, France
[5] CEA LETI, Lab Composants Micro Capteurs, F-38054 Grenoble 9, France
来源:
2014 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS)
|
2014年
关键词:
Electroacoustic transducers;
cMUT;
therapeutic ultrasound;
drug delivery;
preclinical;
imaging;
TRANSDUCERS;
D O I:
10.1109/ULTSYM.2014.0081
中图分类号:
O42 [声学];
学科分类号:
070206 ;
082403 ;
摘要:
This study reports on the development and the first experimental assessment of a custom ultrasound pre-clinical platform developed for diagnosis and targeted therapy. Moreover, a specific dual-mode probe developed for our application is based on cMUT technology. The platform combines two operating modes: high frequency imaging in the 15-20 MHz frequency range and low frequency focused ultrasound at 1 MHz for local therapy.
机构:
Boehringer Ingelheim GmbH & Co KG, Dept Drug Discovery Sci, Biberach, Germany
North West Univ, Dept Pharmaceut Sci, Potchefstroom Campus, Potchefstroom, South AfricaBoehringer Ingelheim GmbH & Co KG, Dept Drug Discovery Sci, Biberach, Germany