Evaluation of various methods of point-of-care testing of haemoglobin concentration in blood donors

被引:29
|
作者
Singh, Abhay [1 ]
Dubey, Anju [2 ]
Sonker, Atul [1 ]
Chaudhary, Rajendra [1 ]
机构
[1] Sanjay Gandhi Post Grad Inst Med Sci, Dept Transfus Med, Lucknow, Uttar Pradesh, India
[2] All India Inst Med Sci, Dept Transfus Med, Rishikesh 249201, Uttarakhand, India
关键词
point-of-care testing; haemoglobin; blood donors; non-invasive; NONINVASIVE HEMOGLOBIN; ACCURACY; VALIDATION; ANALYZER; HEMOCUE;
D O I
10.2450/2014.0085-14
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Point-of-care testing (POCT) devices for determining pre-donation haemoglobin (Hb) concentrations mark the advent of advanced technology for blood banks. POCT devices have undergone several improvements including changes in testing methodology and Size of device, befitting the needs of blood donors and blood banks in terms of safety and quality of blood components. This study was planned to evaluate the suitability of non-invasive and invasive POCT devices for blood donor Hb screening. Material and methods. Pre-donation Hb in apparently healthy blood donors was measured by a non-invasive spectrophotometric based method (NBM-200, OrSense) and an invasive method utilizing reagent free cuvettes (DiaSpect) along with a device using sodium azide-coated cuvettes (HemoControl, EKF diagnostic GmbH). The performance of the devices was evaluated by comparison with the reference method, i.e. an automated cell counter (KX-21). Results. Hb was measured in 485 prospective blood donors. DiaSpect hemoglobin T system was found to be the most sensitive method of POCT for Hb (sensitivity 98.1%) followed by HemoControl (sensitivity 86.8%). NBM-200 was the least sensitive method (sensitivity 71.7%). The intraclass correlation coefficient was highest for DiaSpect (0.78), followed by HemoControl (0.77) and NBM-200 (0.43). The variation of results on repeat testing was high for NBM-200 with a coefficient of variation of 4.28%, compared to 2.19% for DiaSpect. On comparing the mean testing time, DiaSpect (1.9 seconds) was found to be significantly quicker than the other two POCT devices (p<0.001). Discussion. NBM-200 has the apparent advantage of eliminating pain but also a substantial possibility of causing ineligible donors to be accepted. DiaSpect was fast and accurate, with its results showing perfect agreement with those of the standard method. It is, therefore, aptly suited for screening donors in blood banks
引用
收藏
页码:233 / 239
页数:7
相关论文
共 50 条
  • [21] Point-of-care PSA testing: An evaluation of PSAwatch
    Karim, O.
    Rao, A.
    Emberton, M.
    Cochrane, D.
    Partridge, M.
    Edwards, P.
    Walker, I.
    Davidson, I.
    [J]. PROSTATE CANCER AND PROSTATIC DISEASES, 2007, 10 (03) : 270 - 273
  • [22] Calibration of the HemoCue point-of-care analyser for determining haemoglobin concentration in a lizard and a fish
    Andrewartha, Sarah J.
    Munns, Suzanne L.
    Edwards, Ashley
    [J]. CONSERVATION PHYSIOLOGY, 2016, 4
  • [23] Point-of-Care Testing Effectiveness on Blood Donor Hemoglobin Testing
    Grech, Kayleigh
    Zammit, Vanessa
    [J]. LABORATORY MEDICINE, 2021, 52 (04) : 364 - 368
  • [24] Point-of-care estimation of haemoglobin concentration in all age groups in clinical practice
    Schapkaitz, E.
    Mahlangu, J.
    [J]. SOUTH AFRICAN FAMILY PRACTICE, 2011, 53 (03) : 271 - 274
  • [25] Nurse-based evaluation of point-of-care assays for glycated haemoglobin
    St John, A
    Davis, TME
    Goodall, I
    Townsend, MA
    Price, CP
    [J]. CLINICA CHIMICA ACTA, 2006, 365 (1-2) : 257 - 263
  • [26] The point of point-of-care testing
    Kassaye, Seble G.
    Katzenstein, David
    [J]. LANCET, 2011, 378 (9802): : 1532 - 1533
  • [27] Point-of-care testing of haemoglobin levels after surgery for proximal femoral fractures
    Padfield, H.
    Owen, E.
    Edwards, L.
    Gowthaman, S.
    [J]. ANAESTHESIA, 2015, 70 : 58 - 58
  • [28] Point-of-care haemoglobin testing in African hospitals: a neglected essential diagnostic test
    Uyoga, Sophie
    George, Elizabeth C.
    Bates, Imelda
    Olupot-Olupot, Peter
    Chimalizeni, Yami
    Molyneux, Elizabeth M.
    Maitland, Kathryn
    [J]. BRITISH JOURNAL OF HAEMATOLOGY, 2021, 193 (05) : 894 - 901
  • [29] Integrating point-of-care and automated methods for cardiac testing
    Nam, M.
    Lynch, J.
    Norris, N.
    Altenhaus, G.
    [J]. CLINICAL BIOCHEMISTRY, 2008, 41 (14-15) : 1275 - 1275
  • [30] CHARACTERIZATION OF BLOOD DONORS WITH HIGH HAEMOGLOBIN CONCENTRATION
    Magnussen, K.
    Hasselbalch, H. C.
    Ullum, H.
    Bjerrum, O. W.
    [J]. VOX SANGUINIS, 2013, 105 : 15 - 16