Photoacoustic imaging of fibrosarcoma using RGD-Cy 3 as a targeted contrast agent

被引:0
|
作者
Mienkina, M. P. [1 ]
Friedrich, C. -S. [2 ]
Waldeck, J. [3 ]
Hensel, K. [1 ]
Gerhardt, N. C. [4 ]
Bremer, C. [3 ]
Hofmann, M. [2 ]
Schmitz, G. [1 ]
机构
[1] Ruhr Univ Bochum, Inst Med Engn, Bochum, Germany
[2] Ruhr Univ Bochum, Res Grp Optoelectron Devices & Mat, Bochum, Germany
[3] Univ Munster, Univ Hosp Munster, Dept Clin Radiol, Munster, Germany
[4] Photon IQ GbR, Bochum, Germany
关键词
photoacoustics; optoacoustics; Cy; 3; RGD; fluorescence reflectance imaging; M21; cells; HT-1080;
D O I
10.1109/ULTSYM.2007.606
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Photoacoustics (PA) combines the high contrast of optical imaging modalities with the high resolution of clinical ultrasound. Fluorescence mediated tomography (FMT), on the other hand, offers a very high molecular contrast specificity. Therefore, a combination of PA imaging and FMT might be fruitful: e.g. PA imaging could provide valuable a priori information for optical-tomography reconstruction algorithms thereby improving the resolution of FMT. The fusion of PA and FMT will be facilitated by contrast agents that are detectable by both modalities. This study investigates the usage of RGD-Cy 3 as a multimodal contrast agent specific for M21 and HT-1080 tumor cells in vivo (fluorescence reflectance imaging, FRI) and ex vivo (PA). 1.6 mu M of RGD-Cy 3 was Injected into tumor bearing mice (n=4 M21, n=6 HT-1080). The mice were subjected to in vivo FRI. The FRI showed a typical tracer washout time response, however a statistically significant difference between tumor tissue and muscle tissue could not be shown due to auto-fluorescence and hemoglobin absorption. Similar results were obtained 24 h after the injection of the tracer in biodistribution experiments conducted using harvested organs. Subsequently, the organs were PA imaged using a commercial ultrasound system (Sonix RP) and a Nd:YAG laser (532 nm). The kidney exhibited a mean contrast to the noise-floor of 23.97 dB ( +/- 2.65 standard error of the mean (SEM)), the hearts 23.45 dB (+/- 0.63 SEM), and the native tumor 26.09 dB. RGD-Cy 3 labeled tumors showed a gain of 0.26 dB (26.35 dB +/- 0.22 SEM) compared to unlabeled tumors, which was not statistically significant. These results were consistent with in vitro measurements of Cy 3-gelatine mixture phantoms that only showed a 9.4 dB gain compared to the noise-floor for a concentration 81 times higher than in vivo. These findings suggest that RGD-Cy 3 might not be a suitable contrast agent for in vivo PA imaging, although similar fluorochromes like Indocyanine Green were already successfully used for PA imaging.
引用
收藏
页码:2409 / +
页数:2
相关论文
共 50 条
  • [21] Photoacoustic molecular imaging using combined acupuncture and gold nanorods as a composite contrast agent
    Wu, Dan
    Zhang, Xinxin
    Rong, Jian
    Jiang, Huabei
    JOURNAL OF INNOVATIVE OPTICAL HEALTH SCIENCES, 2019, 12 (03)
  • [22] Photoacoustic Imaging Endometriosis Lesions with Nanoparticulate Polydopamine as a Contrast Agent
    Lv, Quanjie
    Zhang, Yili
    Yang, Ruihao
    Dai, Yingfan
    Lin, Yu
    Sun, Kang
    Xu, Hong
    Tao, Ke
    ADVANCED HEALTHCARE MATERIALS, 2024, 13 (02)
  • [23] Multifunctional polyelectrolyte microcapsules as a contrast agent for photoacoustic imaging in blood
    Yashchenok, Alexey M.
    Jose, Jithin
    Trochet, Philippe
    Sukhorukov, Gleb B.
    Gorin, Dmitry A.
    JOURNAL OF BIOPHOTONICS, 2016, 9 (08) : 792 - 799
  • [24] Upconversion Nanoparticles as a Contrast Agent for Photoacoustic Imaging in Live Mice
    Maji, Swarup Kumar
    Sreejith, Sivaramapanicker
    Joseph, James
    Lin, Manjing
    He, Tingchao
    Tong, Yan
    Sun, Handong
    Yu, Sidney Wing-Kwong
    Zhao, Yanli
    ADVANCED MATERIALS, 2014, 26 (32) : 5633 - +
  • [25] Graphene Meets Microbubbles: A Superior Contrast Agent for Photoacoustic Imaging
    Toumia, Yosra
    Domenici, Fabio
    Orlanducci, Silvia
    Mura, Francesco
    Grishenkov, Dmitry
    Trochet, Philippe
    Lacerenza, Savino
    Bordi, Federico
    Paradossi, Gaio
    ACS APPLIED MATERIALS & INTERFACES, 2016, 8 (25) : 16465 - 16475
  • [26] Targeted Aucore-Agshell nanorods as a dual-functional contrast agent for photoacoustic imaging and photothermal therapy
    Shi, Yiwen
    Peng, Dong
    Wang, Kun
    Chai, Xinyu
    Ren, Qiushi
    Tian, Jie
    Zhou, Chuanqing
    BIOMEDICAL OPTICS EXPRESS, 2016, 7 (05): : 1830 - 1841
  • [27] Photoacoustic and Magnetic Resonance Imaging Bimodal Contrast Agent Displaying Amplified Photoacoustic Signal
    Duan, Yukun
    Xu, Yu
    Mao, Duo
    Liew, Weng Heng
    Guo, Bing
    Wang, Shaowei
    Cai, Xiaolei
    Thakor, Nitish
    Yao, Kui
    Zhang, Chong-Jing
    Liu, Bin
    SMALL, 2018, 14 (42)
  • [28] Novel Targeted Contrast Agent for Ultrasound Molecular Imaging of αvβ3 Integrin
    Anderson, Christopher R.
    Rychak, Joshua J.
    Hu, Xiaowen
    Ferrara, Katherine
    FASEB JOURNAL, 2011, 25
  • [29] Modification of surfactant contrast agent for targeted ultrasound imaging
    Oeffinger, BE
    Lathia, JD
    Dhoot, NO
    Barbee, KA
    Wheatley, MA
    PROCEEDINGS OF THE IEEE 29TH ANNUAL NORTHEAST BIOENGINEERING CONFERENCE, 2003, : 305 - 306
  • [30] RGD coated protein microspheres as a dual fluorescent and magnetomotive contrast agent for targeted cancer imaging with magnetomotive optical coherence tomography
    Nguyen, Freddy T.
    John, Renu
    Chaney, Eric J.
    Dibbern, Elizabeth M.
    Suslick, Kenneth S.
    Boppart, Stephen A.
    CANCER RESEARCH, 2010, 70